65.31.8.024.0300 Finder Control Relays

65.31.8.024.0300 on Powermatic Associates
Finder

Part#:65.31.8.024.0300

Manufacturer:Finder

Category:Control Relays

Product Lifecycle:Active

Get a quick Quote!

Finder 65.31.8.024.0300 is a relay designed with 1 Normally Open (NO) pole and 1 Normally Closed (NC) circuit, featuring a fast-on 250 connection type. It supports a rated current of 30A at 250Vac (AC-1) and 30A at 30Vdc, with a reduced current rating at higher DC voltages, including 1.1A at 110Vdc and 0.7A at 220Vdc. The supply voltage is specified as 24Vac (50Hz/60Hz), and it is designed to operate within an ambient air temperature range of -40 to +75 degrees Celsius. The relay offers a rated active power of 2 poles and a control voltage of 4 kV. It is designed for rear flange mounting, with a net depth of 42.2 mm, a mounting mode depth of 32.2 mm, and a power consumption depth of 36.5 mm. The relay is equipped with protection functions rated at 250Vac and is capable of 10,000,000 operations, with its contacts made from AgCdO (Silver Cadmium Oxide). The product is set to be replaced by a model with similar specifications but includes 1 NC pole(s).

About the manufacturer: Finder is one of the manufacturers that offers Control Relays that you can order at Powermatic Associates site. Established in 1993, Finder Relays, Inc., a subsidiary of Finder S.p.A., distributes the Finder product line in the United States. Situated north of Atlanta, Georgia, our facility boasts a robust infrastructure, enabling us to serve customers nationwide effectively.

Check out the 65.31.8.024.0300 Finder price in the box on the right side or send a quick quote.

Product Details

  • Main function
    Relay
  • Connection type
    Fast-on 250
  • Ambient air temperature for operation
    -40...+75 °C
  • Net Width (mm)
    32.2 mm
  • Primary brand
    Finder
  • Product series / family name
    65 series
  • Number of Normally Open (NO) circuits
    1 NO Pole(s)
  • Electrical durability (with load)
    50 000 operations
  • Degree of pollution
    2
  • Rated voltage (AC)
    250Vac
  • Number of Normally Closed (NC) circuits
    1 NC Pole(s)
  • Rated impulse voltage (Uimp)
    4 kV
  • Net Height (mm)
    42.2 mm
  • Rated power
    1250VA (230Vac; AC-15) 7500VA (250Vac; AC-1)
  • Control Voltage (AC)
    24Vac (50Hz/60Hz)
  • Contacts type
    1NO+1NC
  • Contacts coating
    AgCdO (Silver Cadmium Oxide)
  • Rated current
    30A (250Vac; AC-1) 30A (30Vdc; DC-1) 1.1A (110Vdc; DC-1) 0.7A (220Vdc; DC-1)
  • Poles
    2 Pole(s)
  • Mounting mode
    Rear flange
  • Compliant with standard(s)
    cURus EN EC CSA VDE EAC CE EN 60664-1 EN 61000-4-5 EN 61810-1
  • Mechanical durability (at no load)
    10 000 000 operations
  • Net Depth (mm)
    36.5 mm

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents 65.31.8.024.0300 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1