Finder 56.34.9.024.0000T is a relay with a connection type of Fast-on 187, designed for a rated current of 12A at both 250Vac (AC-1) and 30Vdc (DC-1), with lower current ratings of 0.5A at 110Vdc and 0.25A at 220Vdc under DC-1 conditions. It features Normally Open (NO) auxiliary contacts for DC-1 applications. The supply voltage is specified as 4C/O or 4PDT (4 Pole Double Throw), suitable for operating in ambient air temperatures up to 700VA at 230Vac for AC-15 applications and capable of handling 3000VA at 250Vac for AC-1 applications with a speed of 2W. The rated voltage for AC operation spans from -40 to +70 degrees Celsius, with a control voltage (AC) of 4 kV. It is designed with 4 poles, a rated active power (kW) of 4 poles, and a plug-in design for residual current sensitivity. The response time is noted as 2W, and it can handle up to 100,000 operations for Normally Closed (NC) circuits and 10,000,000 operations overall. The relay's contacts are made of AgNi (Silver Nickel), ensuring compatibility with a 24Vdc communication protocol and providing protection functions at 250Vac.

About the manufacturer: Finder is one of the manufacturers that offers Control Relays that you can order at Powermatic Associates site. Established in 1993, Finder Relays, Inc., a subsidiary of Finder S.p.A., distributes the Finder product line in the United States. Situated north of Atlanta, Georgia, our facility boasts a robust infrastructure, enabling us to serve customers nationwide effectively.

Check out the 56.34.9.024.0000T Finder price in the box on the right side or send a quick quote.

Product Details

  • Rated voltage (AC)
    250Vac
  • Contacts type
    4C/O / 4PDT (4 Pole Double Throw)
  • Power consumption
    2 W
  • Application type
    Railway applications
  • Main function
    Relay
  • Connection type
    Fast-on 187
  • Ambient air temperature for operation
    -40...+70 °C
  • Contacts coating
    AgNi (Silver Nickel)
  • Product series / family name
    56T series
  • Rated power
    700VA (230Vac; AC-15) 3000VA (250Vac; AC-1) 2W
  • Control Voltage (DC)
    24Vdc
  • Rated impulse voltage (Uimp)
    4 kV
  • Rated current
    12A (250Vac; AC-1) 12A (30Vdc; DC-1) 0.5A (110Vdc; DC-1) 0.25A (220Vdc; DC-1)
  • Mounting mode
    Plug-in
  • Electrical durability (with load)
    100 000 operations
  • Primary brand
    Finder
  • Poles
    4 Pole(s)
  • Compliant with standard(s)
    CE EN 45545-2 EN 61373 EN 61810-1
  • Mechanical durability (at no load)
    10 000 000 operations

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents 56.34.9.024.0000T Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1