55.34.9.024.5040 Finder Control Relays

55.34.9.024.5040 on Powermatic Associates
Finder

Part#:55.34.9.024.5040

Manufacturer:Finder

Category:Control Relays

Product Lifecycle:Active

Get a quick Quote!

Finder 55.34.9.024.5040 is a relay with solder pin connection type, designed for a rated current of 7A at 250Vac (AC-1) and 7A at 30Vdc (DC-1), with lower current ratings of 0.25A at 110Vdc and 0.12A at 220Vdc for Normally Open (NO) auxiliary contacts. It operates with a supply voltage of 4C/O or 4PDT (4 Pole Double Throw), within an ambient air temperature range for operation of 350VA at 230Vac and for storage at AC-15, indicating a speed of 1750VA at 250Vac (AC-1). The rated voltage for AC operation is specified with a wide ambient temperature range of -40 to +85 degrees Celsius. It supports a communication protocol of type C, with a rated voltage of 24Vdc and protection functions rated at 250Vac. The net depth of the part is 37.2 mm, with a control voltage of 4 kV and a mounting mode width of 27.7 mm. The rated active power is for 4 poles, with a power consumption depth of 20.7 mm. It features plug-in mounting for ease of installation, is designed for up to 150,000 operations for Normally Closed (NC) circuits, and has a durability of 50,000,000 operations. The contacts are made of AgNi+Au (Gold plated silver-nickel), ensuring conductivity and durability.

About the manufacturer: Finder is one of the manufacturers that offers Control Relays that you can order at Powermatic Associates site. Established in 1993, Finder Relays, Inc., a subsidiary of Finder S.p.A., distributes the Finder product line in the United States. Situated north of Atlanta, Georgia, our facility boasts a robust infrastructure, enabling us to serve customers nationwide effectively.

Check out the 55.34.9.024.5040 Finder price in the box on the right side or send a quick quote.

Product Details

  • Rated current
    7A (250Vac; AC-1) 7A (30Vdc; DC-1) 0.25A (110Vdc; DC-1) 0.12A (220Vdc; DC-1)
  • Control Voltage (DC)
    24Vdc
  • Compliant with standard(s)
    ANCE cURus Lloyd Register (LR) CCC RINA IMQ CSA VDE EAC EN 61000-4-4 EN 61000-4-5 EN 61810-1
  • Net Height (mm)
    37.2 mm
  • Main function
    Relay
  • Mounting mode
    Plug-in
  • Mechanical durability (at no load)
    50 000 000 operations
  • Product series / family name
    55 Series
  • Rated voltage (AC)
    250Vac
  • Contacts type
    4C/O / 4PDT (4 Pole Double Throw)
  • Ambient air temperature for operation
    -40...+85 °C
  • Net Depth (mm)
    20.7 mm
  • Poles
    4 Pole(s)
  • Connection type
    Solder pin
  • Rated impulse voltage (Uimp)
    4 kV
  • Primary brand
    Finder
  • Rated power
    350VA (230Vac; AC-15) 1750VA (250Vac; AC-1)
  • Electrical durability (with load)
    150 000 operations
  • Contacts coating
    AgNi+Au (Gold plated silver-nickel)
  • Net Width (mm)
    27.7 mm

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents 55.34.9.024.5040 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1