servo drive CMMT-AS-C2-3A-PN-S1 Mounting type: Mounting plate, bolted, Assembly position: (* Free convection, * Vertical), Product weight: 1300 g, Display: LED green/yellow/red, Control elements: Optional: control unit CDSB

About the manufacturer: Festo is one of the manufacturers that offers Servo Amplifiers that you can order at Powermatic Associates site. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 5340814 Festo price in the box on the right side or send a quick quote.

Product Details

  • Number of safe 2-pin inputs
    2
  • Type code
    CMMT-AS
  • KC characters
    KC EMC
  • Encoder interface, function
    EnDat® 2.1 encoder SIN/COS encoder
  • Encoder interface 2, function
    Incremental encoder SIN/COS encoder
  • Number of diagnostic outputs
    2
  • Pulse energy for braking resistor
    230 Ws
  • Braking resistor nominal power (IEC)
    23 W
  • Information on max. installation height
    1% power reduction/100 m above 1000 m.
  • Mains types
    TT IT
  • Overvoltage category
    III
  • Number of floating switching outputs
    1
  • System voltage to EN 61800-5-1
    300 V
  • Max. current consumption for logic supply with parking brake
    1.5 A
  • Conforms to standard
    EN 61800-3 EN ISO 13849-1
  • Performance Level (PL)
    Safe brake control (SBC)/category 3, performance level e Safe torque off (STO)/category 4, performance level e
  • Output frequency
    0 Hz ... 599 Hz
  • Impedance of setpoint input
    70 kOhm
  • Max. peak current duration
    2 s
  • Mains frequency
    48 Hz ... 62 Hz
  • Nominal operating voltage phases
    1-phase
  • Max. current consumption for logic supply without clamping brake
    0.5 A
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Permissible voltage fluctuations
    -20 % / +15 %
  • Number of digital logic outputs 24 V DC
    6
  • Process interfacing
    AC1: Adjustable-Speed Drives AC4: Synchronous Servo Application
  • Mounting position
    Free convection Vertical
  • Fieldbus interface, connection technology
    RJ45
  • Fieldbus interface, connection type
    2x socket
  • Number of inputs for motor temperature sensor
    1
  • Number of high-speed logic inputs
    2
  • Time resolution of high-speed logic inputs
    1 µs
  • Based on norm
    EN 50581 EN 62061
  • Active PFC
    no
  • Display
    LED green/yellow/red
  • Diagnostic coverage
    97 %
  • Pulse power of braking resistor
    1.6 kVA
  • Nominal operating voltage AC
    230 V
  • Nominal current load supply
    2.8 A
  • SFF safe failure fraction
    99 %
  • Peak current, load supply
    8.4 A
  • Max. current consumption for logic supply with clamping brake and I/O
    2.3 A
  • Load supply permissible range
    -20 %/+15 %
  • Degree of protection
    IP20
  • Product weight
    1300 g
  • Number of digital logic inputs
    12
  • Work range of logic input
    -3 V ... 30 V
  • Encoder interface input, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Fieldbus coupling
    PROFINET
  • Fieldbus interface, transmission rate
    100 Mbit/s
  • Ethernet interface, protocol
    TCP/IP
  • Protection class
    I
  • Fieldbus interface, protocol
    PROFINET IRT PROFINET RT
  • Max. current of the floating switching outputs
    50 mA
  • Max. output current of holding brake
    1 A
  • Max. voltage drop from logic supply to brake output
    0.8 V
  • Time resolution of high-speed switching outputs
    1 µs
  • Controller operating mode
    Cascade control Autotuning
  • Safety integrity level (SIL)
    Safe brake control (SBC)/SIL 3/SILCL 3 Safe torque off (STO)/SIL 3/SILCL 3
  • Control elements
    Optional: CDSB operating unit
  • Characteristics of digital logic outputs
    Freely configurable in some cases Diagnostic outputs in some cases
  • Max. current of digital logic outputs
    20 mA
  • Input voltage range AC
    100 V ... 230 V
  • Nominal current per phase, effective
    2 A
  • Ambient temperature
    0 °C ... 50 °C
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Logic input specification
    Based on IEC 61131-2, type 3
  • Operating range of analog inputs
    ± 10 V
  • Input switching logic
    PNP (positive switching)
  • Fieldbus interface, function
    Bus connection, incoming/forwarding PROFINET slave
  • Ethernet interface, function
    Parameterization and commissioning
  • Synchronization interface, function
    Encoder emulation A/B/Z Encoder input A/B/Z
  • Number of high-speed switching outputs
    2
  • Max. continuous output of the external braking resistor (IEC)
    180 W
  • Max. short circuit protection of mains
    100 kA
  • Max. installation height
    2000 m
  • Safety function
    Safe brake control (SBC) Safe stop 1 (SS1)
  • Line filter
    Integrated
  • Braking resistor, integrated
    100 Ohm
  • Hardware fault tolerance
    1
  • Max. DC link voltage
    395 V
  • Controller nominal power
    350 VA
  • Nominal voltage, load supply DC
    320 V
  • Peak current per phase, effective
    6 A
  • Contamination level
    2
  • Certificate issuing authority
    German Technical Control Board (TÜV) Rheinland 01/205/5640.00/18 UL E331130
  • Relative air humidity
    5 - 90 % Non-condensing
  • Note on ambient temperature
    Above an ambient temperature of 40 °C, the power must be reduced by 3%/°C.
  • Number of analog setpoint inputs
    1
  • Encoder interface output, characteristics
    1 MHz maximum output frequency max. 16384 ppr
  • Switching logic at outputs
    PNP (positive switching)
  • Mode of operation
    Field-oriented regulation 1x SYNC interface for encoder emulation or encoder input
  • Output voltage range AC
    3x (0 – input) V
  • Braking resistor, external
    100 Ohm ... 160 Ohm
  • Max. length of motor cable without ext. mains filter
    25 m
  • Nominal voltage, logic supply DC
    24 V
  • Peak power
    1000 VA
  • Surge resistance
    6 kV
  • Permissible range of logic voltage
    ± 20 %
  • Storage temperature
    -25 °C ... 55 °C
  • UL-ambient temperature
    0 °C ... 40 °C
  • Communication profile
    PROFIdrive PROFIenergy
  • Work range of setpoint input
    ± 10 V
  • Characteristics of setpoint inputs
    Differential inputs Configurable for current/force
  • Note on materials
    Contains paint-wetting impairment substances RoHS-compliant
  • Characteristics of logic input
    Freely configurable in some cases Not galvanically isolated
  • Type of mounting
    Mounting plate, screwed on

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents 5340814 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1