2931685 Festo Pinch Valves

Festo 2931685 Pinch valve VZQA-C-M22U-6-TT-V4V4S1-4 Pneumatically actuated pinch valve in stainless steel, safety position open, NPT thread, DN6, food materials and articles. Design structure: Pneumatically actuated pinch valve, Type of actuation: pneumatic, Sealing pr
Festo

Part#:2931685

Manufacturer:Festo

Alt. Part#:VZQA-C-M22U-6-TT-V4V4S1-4

Product Lifecycle:Active

Get a quick Quote!

Pinch valve VZQA-C-M22U-6-TT-V4V4S1-4 Pneumatically actuated pinch valve in stainless steel, safety position open, NPT thread, DN6, food materials and articles. Design structure: Pneumatically actuated pinch valve, Type of actuation: pneumatic, Sealing pr

About the manufacturer: Festo is one of the manufacturers that offers Pinch Valves that you can order at Powermatic Associates site. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 2931685 Festo price in the box on the right side or send a quick quote.

Product Details

  • Differential pressure
    2.5 bar
  • Type of mounting
    Line installation
  • Valve function
    2/2, open, monostable
  • Type of control
    Externally controlled
  • Symbol
    00995245
  • Housing material
    High-alloy stainless steel
  • Product weight
    157 g
  • Shut-off element material
    VMQ (silicone)
  • Operating pressure
    1 bar ... 6.5 bar
  • Sealing principle
    Soft
  • Flow direction
    Reversible
  • Max. viscosity
    4000 mm²/s
  • Storage temperature
    5 °C ... 30 °C
  • Material number of housing
    1.4404
  • Material of bowl
    PA6
  • Overload pressure
    7.8 bar
  • Design
    Pinch valve, pneumatically operated
  • Fitting connection
    1/4 NPT
  • Reset method
    Rebound resilience
  • Pilot medium
    Compressed air as per ISO 8573-1:2010 [7:4:4]
  • Medium
    Compressed air as per ISO 8573-1:2010 [-:-:-]
  • Note on materials
    Contains paint-wetting impairment substances RoHS-compliant
  • For use in the food industry
    See declaration of conformity
  • Type code
    VZQA
  • Medium pressure
    0 bar ... 4 bar
  • Nominal width DN
    6
  • Nominal pressure of fitting PN
    10
  • Temperature of medium
    -5 °C ... 150 °C
  • On switching time
    125 ms
  • Seals material
    FPM
  • Burst pressure
    16 bar
  • Mounting position
    Any
  • Actuation type
    Pneumatic
  • Auxiliary pilot air port 12
    M5
  • Ambient temperature
    -5 °C ... 60 °C
  • Flow rate Kv
    0.7 m³/h
  • Switching time off
    125 ms
  • Housing cover material
    High-alloy stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents 2931685 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1