Product description

X20 temperature input module, 6 thermocouple inputs, type J, K, N, S, B, R, resolution 0.1°C

Product Details

  • Max. error at 25°C Offset Type R: PtRh13-Pt
    0.09%
  • Temperature Operation Vertical mounting orientation
    0 to 50°C
  • Temperature Operation Horizontal mounting orientation
    0 to 55°C
  • Max. error at 25°C Offset Type B: PtRh30-PtRh6
    0.13%
  • Max. error at 25°C Offset Type S: PtRh10-Pt
    0.11%
  • Max. error at 25°C Offset Type N (Rev. ≥D0)
    0.05%
  • Max. error at 25°C Offset Type K: NiCr-Ni
    0.05%
  • Measurement range Sensor temperature Type R: PtRh13-Pt
    -50 to 1664°C
  • Measurement range Sensor temperature Type S: PtRh10-Pt
    -50 to 1768°C
  • Measurement range Sensor temperature Type B: PtRh30-PtRh6
    0 to 1820°C
  • Max. error at 25°C Offset Type T: Cu-CuNi
    0.04%
  • Measurement range Sensor temperature Type N: NiCrSi-NiSi
    -270 to 1300°C (Rev. ≥D0)
  • Measurement range Sensor temperature Type K: NiCr-Ni
    -270 to 1372°C
  • Measurement range Sensor temperature Type J: Fe-CuNi
    -210 to 1200°C
  • Relative humidity Transport
    5 to 95%, non-condensing
  • Relative humidity Storage
    5 to 95%, non-condensing
  • Relative humidity Operation
    5 to 95%, non-condensing
  • Temperature Transport
    -40 to 85°C
  • Temperature Storage
    -40 to 85°C
  • Installation elevation above sea level 0 to 2000 m
    No limitation
  • Temperature Derating
    -
  • Installation elevation above sea level >2000 m
    Reduction of ambient temperature by 0.5°C per 100 m
  • Mounting orientation Vertical
    Yes
  • Terminal temperature compensation precision With natural convection
    ±2°C after 10 min
  • Mounting orientation Horizontal
    Yes
  • Terminal temperature compensation precision With artificial convection
    ±4°C after 10 min
  • Insulation voltage Between channel and bus
    500 Veff
  • Common-mode rejection 50 Hz
    >70 dB
  • Common-mode rejection DC
    >70 dB
  • Max. offset drift Type R: PtRh13-Pt
    0.0074 %/°C
  • Max. offset drift Type B: PtRh30-PtRh6
    0.0114 %/°C
  • Max. offset drift Type N (Rev. ≥D0)
    0.0029 %/°C
  • Max. offset drift Type S: PtRh10-Pt
    0.0079 %/°C
  • Max. offset drift Type K: NiCr-Ni
    0.0024% / °C
  • Monitoring General fault
    0x8000
  • Max. offset drift Type J: Fe-CuNi
    0.0019 %/°C
  • Max. error at 25°C Gain
    0.06%
  • Monitoring Open inputs
    0x7FFF
  • Monitoring Range overshoot
    0x7FFF
  • Monitoring Open circuit
    0x7FFF
  • Monitoring Range undershoot
    0x8001
  • Normalization Type B: PtRh30-PtRh6
    0 to 1820.0°C
  • Normalization Type R: PtRh13-Pt
    -50.0 to 1664.0°C
  • Normalization Type S: PtRh10-Pt
    -50.0 to 1768.0°C
  • Normalization Terminal temperature
    -25.0 to 85.0°C
  • Normalization Type K: NiCr-Ni
    -270.0 to 1372.0°C
  • Normalization Type N (Rev. ≥D0)
    -270.0 to 1300.0°C
  • Normalization Type J: Fe-CuNi
    -210.0 to 1200.0°C
  • Conversion time 1 channel
    80.4 ms with 50 Hz filter
  • Resolution Raw value output with respect to gain
    1 LSB = 1 µV or 2 µV
  • Resolution Sensor temperature
    1 LSB = 0.1°C
  • Measurement range Raw value
    ±65.534 mV
  • Resolution Terminal temperature
    1 LSB = 0.1°C
  • Conversion time N channels
    (n + 1) x 40.2 ms with 50 Hz filter
  • Measurement range Terminal temperature
    -25 to 85°C
  • Certifications EAC
    Yes
  • Certifications KC
    Yes
  • Certifications ABS
    Yes
  • Certifications KR
    Yes
  • Certifications LR
    ENV1
  • Certifications DNV
    Temperature: B (0 - 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
  • Certifications ATEX
    Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
  • Certifications UL
    cULus E115267; Industrial control equipment
  • Certifications HazLoc
    cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
  • Certifications UKCA
    Yes
  • Certifications CE
    Yes
  • Power consumption Internal I/O
    0.91 W
  • Power consumption Bus
    0.01 W
  • Diagnostics Inputs
    Yes, using LED status indicator and software
  • Pitch
    12.5+0.2 mm
  • Diagnostics Module run/error
    Yes, using LED status indicator and software
  • Note
    Order 1x terminal block X20TB12 separately.; Order 1x bus module X20BM11 separately.
  • Degree of protection per EN 60529
    IP20
  • Electrical isolation
    Channel isolated from bus; Channel not isolated from channel
  • Nonlinearity
    ±0.001%
  • Common-mode range
    ±15 V
  • Max. gain drift
    0.01%/°C
  • Permissible input signal
    Max. ±5 V
  • Crosstalk between channels
    <-70 dB
  • Input filter
    First-order low-pass filter / cutoff frequency 500 Hz
  • Linearization method
    Internal
  • Conversion procedure
    Sigma-delta
  • Terminal temperature compensation
    Internal
  • Sensor standard
    EN 60584
  • Output format
    INT
  • Input
    Thermocouple
  • Filter time
    Configurable between 1 ms and 66.7 ms
  • Status indicators
    I/O function per channel, operating state, module status
  • Digital converter resolution
    16-bit
  • B&R ID code
    0x1BA9
  • I/O module
    6 inputs for thermocouples

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Manufacturer warranty

X20AT6402 B&R

Get a quick Quote!

Request a quote, and we will send you price within minutes.

Stock:

3

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Compare X20AT6402 with other Electronic Components products

Max. error at 25°C Offset...

Temperature Operation Ver...

Temperature Operation Hor...

Max. error at 25°C Offset...

Max. error at 25°C Offset...

Max. error at 25°C Offset...

Max. error at 25°C Offset...

Measurement range Sensor ...

Measurement range Sensor ...

Measurement range Sensor ...

Selected product

X20AT6402
3 in stock
X20AT6402
B&R

X20 temperature input module, 6 thermocouple inputs, type J, K, N, S, B, R, resolution 0.1°C

Max. error at 25°C Offset Type R: PtRh13-Pt0.09%

Temperature Operation Vertical mounting orientation0 to 50°C

Temperature Operation Horizontal mounting orientation0 to 55°C

Max. error at 25°C Offset Type B: PtRh30-PtRh60.13%

Max. error at 25°C Offset Type S: PtRh10-Pt0.11%

Max. error at 25°C Offset Type N (Rev. ≥D0)0.05%

Max. error at 25°C Offset Type K: NiCr-Ni0.05%

Measurement range Sensor temperature Type R: PtRh13-Pt-50 to 1664°C

Measurement range Sensor temperature Type S: PtRh10-Pt-50 to 1768°C

Measurement range Sensor temperature Type B: PtRh30-PtRh60 to 1820°C

X20AO4632
6 in stock
X20AO4632
B&R

X20 analog output module, 4 outputs, ±10 V or 0 to 20 mA, 16-bit converter resolution

Max. error at 25°C Offset Type R: PtRh13-Pt-

Temperature Operation Vertical mounting orientation-

Temperature Operation Horizontal mounting orientation-

Max. error at 25°C Offset Type B: PtRh30-PtRh6-

Max. error at 25°C Offset Type S: PtRh10-Pt-

Max. error at 25°C Offset Type N (Rev. ≥D0)-

Max. error at 25°C Offset Type K: NiCr-Ni-

Measurement range Sensor temperature Type R: PtRh13-Pt-

Measurement range Sensor temperature Type S: PtRh10-Pt-

Measurement range Sensor temperature Type B: PtRh30-PtRh6-

X20AO4622
9 in stock
X20AO4622
B&R

X20 analog output module, 4 outputs, 10 V or 0 to 20 mA / 4 to 20 mA, 13-bit converter resolution

Max. error at 25°C Offset Type R: PtRh13-Pt-

Temperature Operation Vertical mounting orientation-

Temperature Operation Horizontal mounting orientation-

Max. error at 25°C Offset Type B: PtRh30-PtRh6-

Max. error at 25°C Offset Type S: PtRh10-Pt-

Max. error at 25°C Offset Type N (Rev. ≥D0)-

Max. error at 25°C Offset Type K: NiCr-Ni-

Measurement range Sensor temperature Type R: PtRh13-Pt-

Measurement range Sensor temperature Type S: PtRh10-Pt-

Measurement range Sensor temperature Type B: PtRh30-PtRh6-

About the manufacturer

B&R

Powermatic Associates is an authorized B&R distributor, bringing you cutting-edge automation technology from one of the world's leading innovators in industrial automation. B&R, a member of the ABB Group, excels in providing advanced solutions that enhance productivity and efficiency across various industries. With a comprehensive portfolio of products, B&R offers modular hardware and flexible sof...

Recently viewed products

Relevant products

FAQ

3 in stock

X20 temperature input module, 6 thermocouple inputs, type J, K, N, S, B, R, resolution 0.1°C

Similar products from: Electronic Components

What can I help you find today?

Recommended parts