Schneider Electric LC1D50A6JD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A for AC-1 applications and 50A for 440Vac AC-3 applications. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A6JD offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 9-15Vdc (12Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3 applications. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase applications, according to UL/CSA standards. It boasts a mechanical durability of 6,000,000 operations and an electrical durability of 1,450,000 operations with load. The rated voltage (AC) for phase-to-phase applications is 690 V.
Quick Quote
Schneider Electric LC1D40AJ5 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 60A for AC-1 and 40A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 9.6-13.2Vac (12Vac nominal; 50Hz; 0.8...1.1 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. The rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3. It also features 1 normally closed (NC) auxiliary contact with a contact type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in 3-phase, according to UL/CSA standards. Its mechanical durability is rated at 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1D40A3JD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, designed for 3-poles (3P; 3NO) configuration. This contactor supports a rated current of 60A for AC-1 applications and 40A for 440Vac in AC-3 conditions. It is suitable for DIN rail mounting and has a net width of 55 mm. The LC1D40A3JD offers an IP20 degree of protection and operates with a control voltage of 9-15Vdc (12Vdc nominal). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3. Additionally, it has 1 normally closed (NC) auxiliary contact with 1NO+1NC instantaneous auxiliary contacts type. The rated power in horsepower (HP) varies from 3HP at 115Vac to 30HP at 575-600Vac, accommodating both single-phase and 3-phase systems. The mechanical durability is rated at 6,000,000 operations, and electrical durability with load at 1,500,000 operations. The rated voltage for phase-to-phase applications is 690 V.
Quick Quote
Schneider Electric LC1D253N7 is a magnetic contactor from the Deca sub-range, featuring spring connections and designed with 3 poles (3P; 3NO). It has a rated current of 25A for both AC-1 and AC-3 (440Vac) applications. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates within control voltage ranges of 332-456Vac (415Vac nominal; 50Hz; 0.8...1.1 x Uc) and 353-456Vac (415Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 5.5kW at 220-230Vac to 15kW at 660-690Vac in AC-3 category. The rated power in HP varies from 2HP at 115Vac in single-phase to 20HP at 575-600Vac in three-phase applications, according to UL/CSA standards. The mechanical durability of the LC1D253N7 is rated at 15 million operations at no load, and its electrical durability is rated at 1.6 million operations with load. The rated voltage for phase-to-phase applications is 690 V.
Quick Quote
Schneider Electric LC1D18CC7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 32A for AC-1 and 18A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates within a control voltage range of 28.8-39.6Vac at 50Hz and 30.6-39.6Vac at 60Hz, with a nominal control voltage of 36Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 4kW at 220-230Vac to 10kW at 660-690Vac in AC-3 conditions. The rated power in horsepower (HP) varies from 1HP at 115Vac in single-phase to 15HP at 575-600Vac in three-phase, according to UL/CSA standards. The mechanical durability of the LC1D18CC7 is rated at 15 million operations at no load, and its electrical durability is rated at 1.6 million operations with load. The rated voltage for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1D126GD is a magnetic contactor from the Deca sub-range designed for efficient circuit control. It features ring-lugs connections and operates with 3 poles (3P; 3NO). The contactor is rated for currents of 25A (AC-1) and 12A (440Vac; AC-3), and it can be mounted on a DIN rail. With a net width of 45 mm and an IP20 degree of protection, it ensures compatibility with various setups. The control voltage (DC) ranges from 94-156Vdc (125Vdc nominal; 0.75...1.25 x Uc), and it can handle a rated operating voltage (Ue) up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power capacity spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 0.5HP at 115Vac in single-phase to 10HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D126GD is rated at 15 million operations at no load, and its electrical durability with load is 2 million operations. The rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC2D50AGD is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and a mechanical interlock. It has screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 50A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (DC) of 94-156Vdc (125Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous aux. contacts per contactor. The rated impulse voltage (Uimp) is 6 kV. It supports rated active power (kW) of 15kW (220-230Vac; AC-3), 22kW (380-400Vac; AC-3), 25kW (415Vac; AC-3), 30kW (440Vac; AC-3), 30kW (500Vac; AC-3), and 33kW (660-690Vac; AC-3). The rated power (HP) includes 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 7.5HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 15HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 15HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 40HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 40HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC2D183F7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and spring connections. It is designed with 2 x 3-poles (2x3P; 2x3NO) and has a rated current of 32A (AC-1) and 18A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 88-121Vac (110Vac nom.; 50Hz; 0.8...1.1 x Uc) and 93.5-121Vac (110Vac nom.; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The contactor supports rated active power (kW) of 4kW (220-230Vac; AC-3), 7.5kW (380-400Vac; AC-3), 9kW (415Vac; AC-3), 9kW (440Vac; AC-3), 10kW (500Vac; AC-3), and 10kW (660-690Vac; AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor and has a rated power (HP) of 1HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 3HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 5HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 5HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 10HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 15HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1K09008UE7 is a magnetic contactor within the K sub-range, featuring screw connections and a 4-pole (2NO+2NC) configuration. It has a rated current of 20A (AC-1) and 110A (Irms AC), with a net width of 45 mm. This contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 222-318Vac (277Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc). The rated operating voltage (Ue) is 690 V, and it has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV, and it boasts a mechanical durability of 10,000,000 operations at no load. The rated voltage (AC) for phase-to-phase is also 690 V.
Quick Quote
Schneider Electric LC1DT80A3FE7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, ensuring a reliable installation. This 4-pole (4NO) contactor is designed to handle a rated current of 80A under AC-1 conditions and can be mounted on a DIN rail. The unit has a net width of 70 mm and offers a degree of protection rated at IP20. It operates within control voltage ranges of 92-126Vac at 50Hz and 98-126Vac at 60Hz, with a nominal voltage of 115Vac. The LC1DT80A3FE7 includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type, and is capable of withstanding a rated impulse voltage of 6 kV. Its mechanical durability is rated for 6 million operations at no load, and it can handle phase-to-phase rated voltages up to 690 V.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LC1D50A6JD Schneider Electric LC1D50A6JD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor supports a rated current of 80A for AC-1 applications and 50A for 440Vac AC-3 applications. It is designed for DIN rail mounting and has a net width of 55 mm. The LC1D50A6JD offers a degree of protection rated at IP20 and operates with a control voltage (DC) range of 9-15Vdc (12Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3 applications. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 40HP at 575-600Vac in three-phase applications, according to UL/CSA standards. It boasts a mechanical durability of 6,000,000 operations and an electrical durability of 1,450,000 operations with load. The rated voltage (AC) for phase-to-phase applications is 690 V. | Schneider Electric | Quick Quote | |||
LC1D40AJ5 Schneider Electric LC1D40AJ5 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 60A for AC-1 and 40A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 9.6-13.2Vac (12Vac nominal; 50Hz; 0.8...1.1 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. The rated active power spans from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3. It also features 1 normally closed (NC) auxiliary contact with a contact type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac in single-phase to 30HP at 575-600Vac in 3-phase, according to UL/CSA standards. Its mechanical durability is rated at 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1D40A3JD Schneider Electric LC1D40A3JD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, designed for 3-poles (3P; 3NO) configuration. This contactor supports a rated current of 60A for AC-1 applications and 40A for 440Vac in AC-3 conditions. It is suitable for DIN rail mounting and has a net width of 55 mm. The LC1D40A3JD offers an IP20 degree of protection and operates with a control voltage of 9-15Vdc (12Vdc nominal). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3. Additionally, it has 1 normally closed (NC) auxiliary contact with 1NO+1NC instantaneous auxiliary contacts type. The rated power in horsepower (HP) varies from 3HP at 115Vac to 30HP at 575-600Vac, accommodating both single-phase and 3-phase systems. The mechanical durability is rated at 6,000,000 operations, and electrical durability with load at 1,500,000 operations. The rated voltage for phase-to-phase applications is 690 V. | Schneider Electric | Quick Quote | |||
LC1D253N7 Schneider Electric LC1D253N7 is a magnetic contactor from the Deca sub-range, featuring spring connections and designed with 3 poles (3P; 3NO). It has a rated current of 25A for both AC-1 and AC-3 (440Vac) applications. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates within control voltage ranges of 332-456Vac (415Vac nominal; 50Hz; 0.8...1.1 x Uc) and 353-456Vac (415Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 5.5kW at 220-230Vac to 15kW at 660-690Vac in AC-3 category. The rated power in HP varies from 2HP at 115Vac in single-phase to 20HP at 575-600Vac in three-phase applications, according to UL/CSA standards. The mechanical durability of the LC1D253N7 is rated at 15 million operations at no load, and its electrical durability is rated at 1.6 million operations with load. The rated voltage for phase-to-phase applications is 690 V. | Schneider Electric | Quick Quote | |||
LC1D18CC7 Schneider Electric LC1D18CC7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 32A for AC-1 and 18A for 440Vac in AC-3 conditions. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection rated at IP20 and operates within a control voltage range of 28.8-39.6Vac at 50Hz and 30.6-39.6Vac at 60Hz, with a nominal control voltage of 36Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 4kW at 220-230Vac to 10kW at 660-690Vac in AC-3 conditions. The rated power in horsepower (HP) varies from 1HP at 115Vac in single-phase to 15HP at 575-600Vac in three-phase, according to UL/CSA standards. The mechanical durability of the LC1D18CC7 is rated at 15 million operations at no load, and its electrical durability is rated at 1.6 million operations with load. The rated voltage for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1D126GD Schneider Electric LC1D126GD is a magnetic contactor from the Deca sub-range designed for efficient circuit control. It features ring-lugs connections and operates with 3 poles (3P; 3NO). The contactor is rated for currents of 25A (AC-1) and 12A (440Vac; AC-3), and it can be mounted on a DIN rail. With a net width of 45 mm and an IP20 degree of protection, it ensures compatibility with various setups. The control voltage (DC) ranges from 94-156Vdc (125Vdc nominal; 0.75...1.25 x Uc), and it can handle a rated operating voltage (Ue) up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power capacity spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac in AC-3 category. The rated power in horsepower (HP) varies from 0.5HP at 115Vac in single-phase to 10HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D126GD is rated at 15 million operations at no load, and its electrical durability with load is 2 million operations. The rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC2D50AGD Schneider Electric LC2D50AGD is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and a mechanical interlock. It has screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 50A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (DC) of 94-156Vdc (125Vdc nominal; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous aux. contacts per contactor. The rated impulse voltage (Uimp) is 6 kV. It supports rated active power (kW) of 15kW (220-230Vac; AC-3), 22kW (380-400Vac; AC-3), 25kW (415Vac; AC-3), 30kW (440Vac; AC-3), 30kW (500Vac; AC-3), and 33kW (660-690Vac; AC-3). The rated power (HP) includes 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 7.5HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 15HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 15HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 40HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 40HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC2D183F7 Schneider Electric LC2D183F7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and spring connections. It is designed with 2 x 3-poles (2x3P; 2x3NO) and has a rated current of 32A (AC-1) and 18A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 88-121Vac (110Vac nom.; 50Hz; 0.8...1.1 x Uc) and 93.5-121Vac (110Vac nom.; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The contactor supports rated active power (kW) of 4kW (220-230Vac; AC-3), 7.5kW (380-400Vac; AC-3), 9kW (415Vac; AC-3), 9kW (440Vac; AC-3), 10kW (500Vac; AC-3), and 10kW (660-690Vac; AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor and has a rated power (HP) of 1HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 3HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 5HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 5HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 10HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 15HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1K09008UE7 Schneider Electric LC1K09008UE7 is a magnetic contactor within the K sub-range, featuring screw connections and a 4-pole (2NO+2NC) configuration. It has a rated current of 20A (AC-1) and 110A (Irms AC), with a net width of 45 mm. This contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 222-318Vac (277Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc). The rated operating voltage (Ue) is 690 V, and it has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV, and it boasts a mechanical durability of 10,000,000 operations at no load. The rated voltage (AC) for phase-to-phase is also 690 V. | Schneider Electric | Quick Quote | |||
LC1DT80A3FE7 Schneider Electric LC1DT80A3FE7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, ensuring a reliable installation. This 4-pole (4NO) contactor is designed to handle a rated current of 80A under AC-1 conditions and can be mounted on a DIN rail. The unit has a net width of 70 mm and offers a degree of protection rated at IP20. It operates within control voltage ranges of 92-126Vac at 50Hz and 98-126Vac at 60Hz, with a nominal voltage of 115Vac. The LC1DT80A3FE7 includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type, and is capable of withstanding a rated impulse voltage of 6 kV. Its mechanical durability is rated for 6 million operations at no load, and it can handle phase-to-phase rated voltages up to 690 V. | Schneider Electric | Quick Quote |