Found 996 products

Schneider Electric

Schneider Electric LC2D18BDV is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring an electrical/mechanical interlock and a set of reversing power busbars. It offers screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 32A (AC-1) and 18A (440Vac; AC-3). The contactor is designed with a degree of protection of IP20 and operates with a control voltage (DC) of 18-30Vdc (24Vdc nom.; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it can handle rated active power (kW) of 4kW (220-230Vac; AC-3) up to 10kW (660-690Vac; AC-3). Additionally, it features 2 Normally Closed (NC) auxiliary contacts and 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 1HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 15HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA), with a phase-to-phase rated voltage (AC) of 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC2D12U7V is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring an electrical/mechanical interlock and a set of reversing power busbars. It offers screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 25A (AC-1) and 12A (440Vac; AC-3). The contactor is designed with a degree of protection of IP20 and operates within control voltage (AC) ranges of 192-264Vac (240Vac nom.; 50Hz; 0.8...1.1 x Uc) and 204-264Vac (240Vac nom.; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac, all under AC-3 classification. Additionally, it features 2 Normally Closed (NC) auxiliary contacts and 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) varies from 0.5HP at 115Vac to 10HP at 575-600Vac, accommodating a wide range of applications. The rated voltage (AC) for phase-to-phase connections is 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC2D12N7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and screw connections. It has 2 x 3-poles (2x3P; 2x3NO) and is rated for a current of 25A (AC-1) and 12A (440Vac; AC-3). The degree of protection provided is IP20. Control voltage (AC) specifications are 332-456Vac (415Vac nominal; 50Hz; 0.8...1.1 x Uc) and 353-456Vac (415Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac, all under AC-3 classification. Contacts type includes 1NO+1NC instantaneous auxiliary contacts per contactor. Rated power (HP) ranges from 0.5HP at 115Vac to 10HP at 575-600Vac, with phase-to-phase rated voltage (AC) at 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC2D12JD is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and screw connections. It has 2 x 3-poles (2x3P; 2x3NO) with a rated current of 25A (AC-1) and 12A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (DC) of 9-15Vdc (12Vdc nom.; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The rated active power (kW) spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac, all within AC-3 classification. It also features 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 0.5HP at 115Vac to 10HP at 575-600Vac, accommodating various single-phase and 3-phase configurations under UL/CSA standards. The rated voltage (AC) for phase-to-phase connections is 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC2D126M7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and ring-lugs connections. It is designed with 2 x 3-poles (2x3P; 2x3NO) and has a rated current of 25A for AC-1 and 12A for 440Vac in AC-3. The contactor offers a degree of protection of IP20 and operates within control voltage ranges of 176-242Vac (220Vac nominal; 50Hz; 0.8...1.1 x Uc) and 187-242Vac (220Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac in AC-3. Additionally, it features 2 Normally Closed (NC) auxiliary contacts and 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power in horsepower (HP) ranges from 0.5HP at 115Vac in single-phase to 10HP at 575-600Vac in three-phase, with a phase-to-phase rated voltage of 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC2D126F7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and ring-lugs connections. It has 2 x 3-poles (2x3P; 2x3NO) configuration with a rated current of 25A (AC-1) and 12A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 88-121Vac (110Vac nominal; 50Hz; 0.8...1.1 x Uc) and 93.5-121Vac (110Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The rated active power (kW) spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac (all AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 0.5HP at 115Vac to 10HP at 575-600Vac, accommodating various single-phase and 3-phase applications under UL/CSA standards. The rated voltage (AC) for phase-to-phase applications is 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC2D126B7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and ring-lugs connections. It has 2 x 3-poles (2x3P; 2x3NO) with a rated current of 25A (AC-1) and 12A (440Vac; AC-3). The degree of protection is IP20, and it operates with a control voltage (AC) of 19.2-26.4Vac (24Vac nominal; 50Hz; 0.8...1.1 x Uc) and 20.4-26.4Vac (24Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. Its rated active power (kW) spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac (AC-3), and it has 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 0.5HP at 115Vac to 10HP at 575-600Vac, with a phase-to-phase rated voltage (AC) of 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC2D09D7 is a pre-assembled reversing magnetic contactor within the Deca sub-range, featuring a mechanical interlock and screw connections. It is designed with 2 x 3-poles (2x3P; 2x3NO) and has a rated current of 25A (AC-1) and 9A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) range of 33.6-46.2Vac (42Vac nominal; 50Hz; 0.8...1.1 x Uc) and 35.7-46.2Vac (42Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 2.2kW at 220-230Vac to 5.5kW at 660-690Vac (AC-3), complemented by Normally Closed (NC) auxiliary contacts (2 NC contacts) and 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 0.33HP at 115Vac to 7.5HP at 575-600Vac, with a phase-to-phase rated voltage (AC) of 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC2D096B7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and ring-lugs connections. It is designed with 2 x 3-poles (2x3P; 2x3NO) and has a rated current of 25A (AC-1) and 9A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) range of 19.2-26.4Vac (24Vac nominal; 50Hz; 0.8...1.1 x Uc) and 20.4-26.4Vac (24Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The contactor supports rated active power (kW) of 2.2kW (220-230Vac; AC-3), 4kW (380-400Vac; AC-3), 4kW (415Vac; AC-3), 4kW (440Vac; AC-3), 5.5kW (500Vac; AC-3), and 5.5kW (660-690Vac; AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor and supports rated power (HP) of 0.33HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 1HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 2HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 2HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 5HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 7.5HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) phase-to-phase is 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC1SK0600Q7 is a magnetic mini-contactor from the SK sub-range designed for efficient operation. It features screw connections and is equipped with 2 poles (2NO) for circuit control. The contactor is rated for currents of 12A under AC-1 conditions and 6A at 400Vac under AC-3 conditions. It operates with a control voltage (AC) range of 323-418Vac (380Vac nominal; 50Hz/60Hz; 0.85...1.1 x Uc) and has a rated operating voltage (Ue) of 690 V. This model does not include normally open (NO) or normally closed (NC) auxiliary contacts. It is capable of handling rated active power of 1.1kW at 220-230Vac, 2.2kW at 380-415Vac, and 2.2kW at 660-690Vac, all under AC-3 conditions. The LC1SK0600Q7 boasts a mechanical durability of 10 million operations at no load and an electrical durability of 600,000 operations with load, ensuring a long service life. The rated voltage (AC) for phase-to-phase connections is 690 V.

Quick Quote

ItemManufacturerPriceStockDelivery

LC2D18BDV

Schneider Electric LC2D18BDV is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring an electrical/mechanical interlock and a set of reversing power busbars. It offers screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 32A (AC-1) and 18A (440Vac; AC-3). The contactor is designed with a degree of protection of IP20 and operates with a control voltage (DC) of 18-30Vdc (24Vdc nom.; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it can handle rated active power (kW) of 4kW (220-230Vac; AC-3) up to 10kW (660-690Vac; AC-3). Additionally, it features 2 Normally Closed (NC) auxiliary contacts and 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 1HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 15HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA), with a phase-to-phase rated voltage (AC) of 690 V.

Schneider Electric

Quick Quote

LC2D12U7V

Schneider Electric LC2D12U7V is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring an electrical/mechanical interlock and a set of reversing power busbars. It offers screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 25A (AC-1) and 12A (440Vac; AC-3). The contactor is designed with a degree of protection of IP20 and operates within control voltage (AC) ranges of 192-264Vac (240Vac nom.; 50Hz; 0.8...1.1 x Uc) and 204-264Vac (240Vac nom.; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac, all under AC-3 classification. Additionally, it features 2 Normally Closed (NC) auxiliary contacts and 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) varies from 0.5HP at 115Vac to 10HP at 575-600Vac, accommodating a wide range of applications. The rated voltage (AC) for phase-to-phase connections is 690 V.

Schneider Electric

Quick Quote

LC2D12N7

Schneider Electric LC2D12N7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and screw connections. It has 2 x 3-poles (2x3P; 2x3NO) and is rated for a current of 25A (AC-1) and 12A (440Vac; AC-3). The degree of protection provided is IP20. Control voltage (AC) specifications are 332-456Vac (415Vac nominal; 50Hz; 0.8...1.1 x Uc) and 353-456Vac (415Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac, all under AC-3 classification. Contacts type includes 1NO+1NC instantaneous auxiliary contacts per contactor. Rated power (HP) ranges from 0.5HP at 115Vac to 10HP at 575-600Vac, with phase-to-phase rated voltage (AC) at 690 V.

Schneider Electric

Quick Quote

LC2D12JD

Schneider Electric LC2D12JD is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and screw connections. It has 2 x 3-poles (2x3P; 2x3NO) with a rated current of 25A (AC-1) and 12A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (DC) of 9-15Vdc (12Vdc nom.; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The rated active power (kW) spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac, all within AC-3 classification. It also features 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 0.5HP at 115Vac to 10HP at 575-600Vac, accommodating various single-phase and 3-phase configurations under UL/CSA standards. The rated voltage (AC) for phase-to-phase connections is 690 V.

Schneider Electric

Quick Quote

LC2D126M7

Schneider Electric LC2D126M7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and ring-lugs connections. It is designed with 2 x 3-poles (2x3P; 2x3NO) and has a rated current of 25A for AC-1 and 12A for 440Vac in AC-3. The contactor offers a degree of protection of IP20 and operates within control voltage ranges of 176-242Vac (220Vac nominal; 50Hz; 0.8...1.1 x Uc) and 187-242Vac (220Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac in AC-3. Additionally, it features 2 Normally Closed (NC) auxiliary contacts and 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power in horsepower (HP) ranges from 0.5HP at 115Vac in single-phase to 10HP at 575-600Vac in three-phase, with a phase-to-phase rated voltage of 690 V.

Schneider Electric

Quick Quote

LC2D126F7

Schneider Electric LC2D126F7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and ring-lugs connections. It has 2 x 3-poles (2x3P; 2x3NO) configuration with a rated current of 25A (AC-1) and 12A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 88-121Vac (110Vac nominal; 50Hz; 0.8...1.1 x Uc) and 93.5-121Vac (110Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The rated active power (kW) spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac (all AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 0.5HP at 115Vac to 10HP at 575-600Vac, accommodating various single-phase and 3-phase applications under UL/CSA standards. The rated voltage (AC) for phase-to-phase applications is 690 V.

Schneider Electric

Quick Quote

LC2D126B7

Schneider Electric LC2D126B7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and ring-lugs connections. It has 2 x 3-poles (2x3P; 2x3NO) with a rated current of 25A (AC-1) and 12A (440Vac; AC-3). The degree of protection is IP20, and it operates with a control voltage (AC) of 19.2-26.4Vac (24Vac nominal; 50Hz; 0.8...1.1 x Uc) and 20.4-26.4Vac (24Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. Its rated active power (kW) spans from 3kW at 220-230Vac to 7.5kW at 660-690Vac (AC-3), and it has 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 0.5HP at 115Vac to 10HP at 575-600Vac, with a phase-to-phase rated voltage (AC) of 690 V.

Schneider Electric

Quick Quote

LC2D09D7

Schneider Electric LC2D09D7 is a pre-assembled reversing magnetic contactor within the Deca sub-range, featuring a mechanical interlock and screw connections. It is designed with 2 x 3-poles (2x3P; 2x3NO) and has a rated current of 25A (AC-1) and 9A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) range of 33.6-46.2Vac (42Vac nominal; 50Hz; 0.8...1.1 x Uc) and 35.7-46.2Vac (42Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 2.2kW at 220-230Vac to 5.5kW at 660-690Vac (AC-3), complemented by Normally Closed (NC) auxiliary contacts (2 NC contacts) and 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 0.33HP at 115Vac to 7.5HP at 575-600Vac, with a phase-to-phase rated voltage (AC) of 690 V.

Schneider Electric

Quick Quote

LC2D096B7

Schneider Electric LC2D096B7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and ring-lugs connections. It is designed with 2 x 3-poles (2x3P; 2x3NO) and has a rated current of 25A (AC-1) and 9A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) range of 19.2-26.4Vac (24Vac nominal; 50Hz; 0.8...1.1 x Uc) and 20.4-26.4Vac (24Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The contactor supports rated active power (kW) of 2.2kW (220-230Vac; AC-3), 4kW (380-400Vac; AC-3), 4kW (415Vac; AC-3), 4kW (440Vac; AC-3), 5.5kW (500Vac; AC-3), and 5.5kW (660-690Vac; AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor and supports rated power (HP) of 0.33HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 1HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 2HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 2HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 5HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 7.5HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) phase-to-phase is 690 V.

Schneider Electric

Quick Quote

LC1SK0600Q7

Schneider Electric LC1SK0600Q7 is a magnetic mini-contactor from the SK sub-range designed for efficient operation. It features screw connections and is equipped with 2 poles (2NO) for circuit control. The contactor is rated for currents of 12A under AC-1 conditions and 6A at 400Vac under AC-3 conditions. It operates with a control voltage (AC) range of 323-418Vac (380Vac nominal; 50Hz/60Hz; 0.85...1.1 x Uc) and has a rated operating voltage (Ue) of 690 V. This model does not include normally open (NO) or normally closed (NC) auxiliary contacts. It is capable of handling rated active power of 1.1kW at 220-230Vac, 2.2kW at 380-415Vac, and 2.2kW at 660-690Vac, all under AC-3 conditions. The LC1SK0600Q7 boasts a mechanical durability of 10 million operations at no load and an electrical durability of 600,000 operations with load, ensuring a long service life. The rated voltage (AC) for phase-to-phase connections is 690 V.

Schneider Electric

Quick Quote