All categories
Contactors
All categories
Contactors
Schneider Electric LC2D65AK7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and a mechanical interlock. It has screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 65A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 80-110Vac (100Vac nominal; 50Hz; 0.8...1.1 x Uc) and 85-110Vac (100Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The contactor supports a rated active power (kW) of 18.5kW (220-230Vac; AC-3), 30kW (380-400Vac; AC-3), 37kW (415Vac; AC-3), 37kW (440Vac; AC-3), 37kW (500Vac; AC-3), and 37kW (660-690Vac; AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor and has a rated power (HP) of 5HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 10HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 20HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 20HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 40HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 50HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1DT80A3B7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals. It is designed with spring connections for control and screw connections for power, and it has 4 poles (4NO). This contactor is rated for 80A (AC-1), suitable for DIN rail mounting, and has a net width of 70 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) of 19.2-26.4Vac (24Vac nominal; 50Hz; 0.8...1.1 x Uc) or 20.4-26.4Vac (24Vac nominal; 60Hz; 0.85...1.1 x Uc). The LC1DT80A3B7 includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). It has a mechanical durability of 6 million operations at no load and can handle a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) phase-to-phase is up to 690 V.
Quick Quote
Schneider Electric LC2D50AU7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and a mechanical interlock. It has screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 50A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 192-264Vac (240Vac nominal; 50Hz; 0.8...1.1 x Uc) and 204-264Vac (240Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+1NC instantaneous auxiliary contacts per contactor. The rated impulse voltage (Uimp) is 6 kV. It supports a rated active power (kW) of 15kW (220-230Vac; AC-3), 22kW (380-400Vac; AC-3), 25kW (415Vac; AC-3), 30kW (440Vac; AC-3), 30kW (500Vac; AC-3), and 33kW (660-690Vac; AC-3). The rated power (HP) is 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 7.5HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 15HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 15HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 40HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 40HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA), with a phase-to-phase rated voltage (AC) of 690 V.
Quick Quote
Schneider Electric LC1K09107U7 is a magnetic contactor within the K sub-range, featuring Faston spade connections for quick installation. This 3-pole (3P; 3NO) contactor is designed to handle a rated current of 20A under AC-1 conditions and 9A at 440Vac under AC-3 conditions. It measures 45 mm in net width and offers an IP20 degree of protection. The control voltage (AC) ranges from 192-276Vac (230/240Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc), with a rated operating voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) auxiliary contact, has a rated impulse voltage (Uimp) of 8 kV, and supports rated active power (kW) of 2.2kW at 220-230Vac, 4kW at 380-415Vac, 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. This unit has no Normally Closed (NC) auxiliary contacts and boasts a mechanical durability of 10 million operations at no load, with a phase-to-phase rated voltage (AC) of 690 V.
Quick Quote
Schneider Electric LC2D40A3P7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) term. power connection by Everlink mechanical interlock. It has spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). The contactor is designed with a degree of protection of IP20 and operates with a control voltage (AC) of 184-253Vac (230Vac nom.; 50Hz; 0.8...1.1 x Uc) and 195.5-253Vac (230Vac nom.; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The rated active power (kW) spans from 11kW at 220-230Vac to 30kW at 660-690Vac, all within AC-3 classification. It also features 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) varies from 3HP at 115Vac to 30HP at 575-600Vac, accommodating both single-phase and 3-phase connections, with compliance to UL/CSA standards. The rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1DT60A6P7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with ring-lugs connections and has a 4-pole (4P; 4NO) configuration. The rated current for this contactor is 60A under AC-1 conditions. It is designed for DIN rail mounting and has a net width of 70 mm. The LC1DT60A6P7 offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 184-253Vac (230Vac nominal; 50Hz; 0.8...1.1 x Uc) and 195.5-253Vac (230Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous auxiliaries. The mechanical durability of this contactor is rated at 6,000,000 operations at no load, and it can handle a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase connections is up to 690 V.
Quick Quote
Schneider Electric LC2D50A3E7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal power connections with an Everlink mechanical interlock. It utilizes spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 50A (440Vac; AC-3). The contactor is designed with an IP20 degree of protection and operates with a control voltage (AC) of 38.4-52.8Vac (48Vac nominal; 50Hz; 0.8...1.1 x Uc) and 40.8-52.8Vac (48Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 15kW at 220-230Vac to 33kW at 660-690Vac (all AC-3), and it also features 2 Normally Closed (NC) auxiliary contacts. The contactor has 1NO+1NC instantaneous auxiliary contacts per contactor and supports rated power (HP) for various voltages and phases, including 3HP at 115Vac and up to 40HP at 575-600Vac, with a phase-to-phase rated voltage (AC) of 690 V.
Quick Quote
Schneider Electric LC1D65AMD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 65A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 165-275Vdc (220Vdc nominal; 0.75...1.25 x Uc), and it operates at a rated operating voltage (Ue) of up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65AMD is rated at 6 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage (AC) for phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC2DT32M7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock design and screw connections. It is equipped with 2 x 4-poles (2x4NO) and has a rated current of 32A (AC-1). The degree of protection provided is IP20. This contactor operates with a control voltage (AC) of 176-242Vac (220Vac nominal; 50Hz; 0.8...1.1 x Uc) and 187-242Vac (220Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The contacts type is 1NO+1NC instantaneous auxiliary contacts per contactor. The rated impulse voltage (Uimp) is 6 kV, and the rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC2F115 is a pre-assembled reversing high-power magnetic contactor within the F sub-range. It features a mechanical interlock design and offers ring-lugs/bar connections for installation. This contactor is equipped with 2 x 3-poles (2x3P; 2x3NO) and supports a rated current of 200A under AC-1 conditions and 115A at 440Vac under AC-3 conditions. The rated operating voltage (Ue) is up to 1000 V, with no Normally Open (NO) or Normally Closed (NC) auxiliary contacts included. It has a rated impulse voltage (Uimp) of 8 kV. The rated active power varies with voltage, providing 30kW at 220-230Vac, 55kW at 380-400Vac, 59kW at both 415Vac and 440Vac, 75kW at 500Vac, 80kW at 660-690Vac, and 65kW at 1000Vac, all under AC-3 conditions. The rated voltage for phase-to-phase connections is 1000 V.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LC2D65AK7 Schneider Electric LC2D65AK7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and a mechanical interlock. It has screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 65A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 80-110Vac (100Vac nominal; 50Hz; 0.8...1.1 x Uc) and 85-110Vac (100Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The contactor supports a rated active power (kW) of 18.5kW (220-230Vac; AC-3), 30kW (380-400Vac; AC-3), 37kW (415Vac; AC-3), 37kW (440Vac; AC-3), 37kW (500Vac; AC-3), and 37kW (660-690Vac; AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor and has a rated power (HP) of 5HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 10HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 20HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 20HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 40HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 50HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1DT80A3B7 Schneider Electric LC1DT80A3B7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals. It is designed with spring connections for control and screw connections for power, and it has 4 poles (4NO). This contactor is rated for 80A (AC-1), suitable for DIN rail mounting, and has a net width of 70 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) of 19.2-26.4Vac (24Vac nominal; 50Hz; 0.8...1.1 x Uc) or 20.4-26.4Vac (24Vac nominal; 60Hz; 0.85...1.1 x Uc). The LC1DT80A3B7 includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). It has a mechanical durability of 6 million operations at no load and can handle a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) phase-to-phase is up to 690 V. | Schneider Electric | Quick Quote | |||
LC2D50AU7 Schneider Electric LC2D50AU7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and a mechanical interlock. It has screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 50A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 192-264Vac (240Vac nominal; 50Hz; 0.8...1.1 x Uc) and 204-264Vac (240Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+1NC instantaneous auxiliary contacts per contactor. The rated impulse voltage (Uimp) is 6 kV. It supports a rated active power (kW) of 15kW (220-230Vac; AC-3), 22kW (380-400Vac; AC-3), 25kW (415Vac; AC-3), 30kW (440Vac; AC-3), 30kW (500Vac; AC-3), and 33kW (660-690Vac; AC-3). The rated power (HP) is 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 7.5HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 15HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 15HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 40HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 40HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA), with a phase-to-phase rated voltage (AC) of 690 V. | Schneider Electric | Quick Quote | |||
LC1K09107U7 Schneider Electric LC1K09107U7 is a magnetic contactor within the K sub-range, featuring Faston spade connections for quick installation. This 3-pole (3P; 3NO) contactor is designed to handle a rated current of 20A under AC-1 conditions and 9A at 440Vac under AC-3 conditions. It measures 45 mm in net width and offers an IP20 degree of protection. The control voltage (AC) ranges from 192-276Vac (230/240Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc), with a rated operating voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) auxiliary contact, has a rated impulse voltage (Uimp) of 8 kV, and supports rated active power (kW) of 2.2kW at 220-230Vac, 4kW at 380-415Vac, 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. This unit has no Normally Closed (NC) auxiliary contacts and boasts a mechanical durability of 10 million operations at no load, with a phase-to-phase rated voltage (AC) of 690 V. | Schneider Electric | Quick Quote | |||
LC2D40A3P7 Schneider Electric LC2D40A3P7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) term. power connection by Everlink mechanical interlock. It has spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). The contactor is designed with a degree of protection of IP20 and operates with a control voltage (AC) of 184-253Vac (230Vac nom.; 50Hz; 0.8...1.1 x Uc) and 195.5-253Vac (230Vac nom.; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The rated active power (kW) spans from 11kW at 220-230Vac to 30kW at 660-690Vac, all within AC-3 classification. It also features 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) varies from 3HP at 115Vac to 30HP at 575-600Vac, accommodating both single-phase and 3-phase connections, with compliance to UL/CSA standards. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1DT60A6P7 Schneider Electric LC1DT60A6P7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with ring-lugs connections and has a 4-pole (4P; 4NO) configuration. The rated current for this contactor is 60A under AC-1 conditions. It is designed for DIN rail mounting and has a net width of 70 mm. The LC1DT60A6P7 offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 184-253Vac (230Vac nominal; 50Hz; 0.8...1.1 x Uc) and 195.5-253Vac (230Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous auxiliaries. The mechanical durability of this contactor is rated at 6,000,000 operations at no load, and it can handle a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase connections is up to 690 V. | Schneider Electric | Quick Quote | |||
LC2D50A3E7 Schneider Electric LC2D50A3E7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal power connections with an Everlink mechanical interlock. It utilizes spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 50A (440Vac; AC-3). The contactor is designed with an IP20 degree of protection and operates with a control voltage (AC) of 38.4-52.8Vac (48Vac nominal; 50Hz; 0.8...1.1 x Uc) and 40.8-52.8Vac (48Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 15kW at 220-230Vac to 33kW at 660-690Vac (all AC-3), and it also features 2 Normally Closed (NC) auxiliary contacts. The contactor has 1NO+1NC instantaneous auxiliary contacts per contactor and supports rated power (HP) for various voltages and phases, including 3HP at 115Vac and up to 40HP at 575-600Vac, with a phase-to-phase rated voltage (AC) of 690 V. | Schneider Electric | Quick Quote | |||
LC1D65AMD Schneider Electric LC1D65AMD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 65A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 165-275Vdc (220Vdc nominal; 0.75...1.25 x Uc), and it operates at a rated operating voltage (Ue) of up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65AMD is rated at 6 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage (AC) for phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC2DT32M7 Schneider Electric LC2DT32M7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock design and screw connections. It is equipped with 2 x 4-poles (2x4NO) and has a rated current of 32A (AC-1). The degree of protection provided is IP20. This contactor operates with a control voltage (AC) of 176-242Vac (220Vac nominal; 50Hz; 0.8...1.1 x Uc) and 187-242Vac (220Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The contacts type is 1NO+1NC instantaneous auxiliary contacts per contactor. The rated impulse voltage (Uimp) is 6 kV, and the rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC2F115 Schneider Electric LC2F115 is a pre-assembled reversing high-power magnetic contactor within the F sub-range. It features a mechanical interlock design and offers ring-lugs/bar connections for installation. This contactor is equipped with 2 x 3-poles (2x3P; 2x3NO) and supports a rated current of 200A under AC-1 conditions and 115A at 440Vac under AC-3 conditions. The rated operating voltage (Ue) is up to 1000 V, with no Normally Open (NO) or Normally Closed (NC) auxiliary contacts included. It has a rated impulse voltage (Uimp) of 8 kV. The rated active power varies with voltage, providing 30kW at 220-230Vac, 55kW at 380-400Vac, 59kW at both 415Vac and 440Vac, 75kW at 500Vac, 80kW at 660-690Vac, and 65kW at 1000Vac, all under AC-3 conditions. The rated voltage for phase-to-phase connections is 1000 V. | Schneider Electric | Quick Quote |