Schneider Electric LC1DPKB7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 24Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+2NC instantaneous auxiliaries. The LC1DPKB7 has an electrical durability of 300,000 operations at 400Vac and 200,000 operations at 690Vac, with a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase is also 690 V.
Quick Quote
Schneider Electric LC1DMKE7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 48Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 2 normally closed (NC) auxiliary contacts, with a contact type of 1NO+2NC instantaneous auxiliaries. The LC1DMKE7 has an electrical durability of 300,000 operations at 400Vac and 200,000 operations at 690Vac, with a rated impulse voltage (Uimp) of 6 kV and a phase-to-phase rated voltage (AC) of 690 V.
Quick Quote
Schneider Electric LC1DGKU7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 240Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 2 normally closed (NC) auxiliary contacts, with a contact type of 1NO+2NC instantaneous auxiliaries. The LC1DGKU7 has a rated impulse voltage (Uimp) of 6 kV and demonstrates electrical durability of 300,000 operations at 400Vac and 200,000 operations at 690Vac. The rated voltage (AC) for phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1DFKG7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 120Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 2 normally closed (NC) auxiliary contacts, with the contacts type being 1NO+2NC instantaneous auxiliaries. The LC1DFKG7 has an electrical durability of 300,000 operations at 400Vac and 200,000 operations at 690Vac, with a rated impulse voltage (Uimp) of 6 kV and a phase-to-phase rated voltage (AC) of 690 V.
Quick Quote
Schneider Electric LC1D806U7 is a magnetic contactor from the Deca sub-range, designed for ring-lugs connections. This 3-pole (3NO) contactor supports a rated current of 125A for AC-1 applications and 80A for 440Vac AC-3 applications. It is suitable for DIN rail mounting and has a net width of 85 mm. The LC1D806U7 offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 192-264Vac (240Vac nominal; 50Hz; 0.8...1.1 x Uc) and 204-264Vac (240Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is up to 1000 V, and it features 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 8 kV. This contactor can handle rated active power ranging from 22kW at 220-230Vac to 55kW at 500Vac in AC-3 applications, and it supports rated power in horsepower (HP) from 7.5HP at 115Vac to 60HP at 575-600Vac, covering both single-phase and 3-phase applications under UL/CSA standards. It boasts a mechanical durability of 4,000,000 operations and an electrical durability of 1,500,000 operations with load, ensuring a robust performance for a wide range of industrial applications. The rated voltage for phase-to-phase applications is 1000 V.
Quick Quote
Schneider Electric LC1D80008M6 is a magnetic contactor from the Deca sub-range, featuring screw connections and a 4-pole (2NO+2NC) configuration. It has a rated current of 125A (AC-1) and is designed for DIN rail mounting. The net width of the contactor is 96 mm, and it offers a degree of protection of IP20. The control voltage (AC) ranges from 187-242Vac (220Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. This model includes 0 normally open (NO) auxiliary contacts and 0 normally closed (NC) auxiliary contacts. It is capable of withstanding a rated impulse voltage (Uimp) of 8 kV and has a mechanical durability of 4,000,000 operations at no load. The rated voltage (AC) for phase-to-phase is 1000 V.
Quick Quote
Schneider Electric LC1D65ASC7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 65A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 460-632Vac at 50Hz and 489-632Vac at 60Hz, with a nominal control voltage of 575Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65ASC7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1D65A3G7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor is designed for a rated current of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It supports DIN rail mounting and has a net width of 55 mm. The LC1D65A3G7 offers an IP20 degree of protection and operates with a control voltage of 96-132Vac at 50Hz and 102-132Vac at 60Hz. Its rated operating voltage (Ue) reaches up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. It also supports various rated power (HP) levels for different voltages and phases, including 5HP at 115Vac single-phase and up to 50HP at 575-600Vac three-phase, according to UL/CSA standards. The mechanical durability of the LC1D65A3G7 is rated at 6 million operations, and its electrical durability with load is 1.4 million operations. The rated voltage for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1D50AND is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 50A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 45-75Vdc, with a nominal value of 60Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor supports rated active power from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3, and it has both 1NO+1NC instantaneous auxiliary contacts. The rated power in horsepower (HP) varies from 3HP at 115Vac to 40HP at 575-600Vac, suitable for both single-phase and 3-phase systems. It boasts a mechanical durability of 6 million operations and an electrical durability of 1.45 million operations with load, with a phase-to-phase rated voltage of 690 V.
Quick Quote
Schneider Electric LC1D50A3T7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for connection. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor is designed for a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It supports DIN rail mounting and has a net width of 55 mm. The LC1D50A3T7 offers a degree of protection rated at IP20 and operates with a control voltage range of 384-528Vac at 50Hz and 408-528Vac at 60Hz, with a nominal control voltage of 480Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. It also supports various rated power (HP) settings for different voltages and phases under UL/CSA standards, including 3HP at 115Vac and up to 40HP at 575-600Vac. The mechanical durability of the LC1D50A3T7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.45 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LC1DPKB7 Schneider Electric LC1DPKB7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 24Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+2NC instantaneous auxiliaries. The LC1DPKB7 has an electrical durability of 300,000 operations at 400Vac and 200,000 operations at 690Vac, with a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase is also 690 V. | Schneider Electric | Quick Quote | |||
LC1DMKE7 Schneider Electric LC1DMKE7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 48Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 2 normally closed (NC) auxiliary contacts, with a contact type of 1NO+2NC instantaneous auxiliaries. The LC1DMKE7 has an electrical durability of 300,000 operations at 400Vac and 200,000 operations at 690Vac, with a rated impulse voltage (Uimp) of 6 kV and a phase-to-phase rated voltage (AC) of 690 V. | Schneider Electric | Quick Quote | |||
LC1DGKU7 Schneider Electric LC1DGKU7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 240Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 2 normally closed (NC) auxiliary contacts, with a contact type of 1NO+2NC instantaneous auxiliaries. The LC1DGKU7 has a rated impulse voltage (Uimp) of 6 kV and demonstrates electrical durability of 300,000 operations at 400Vac and 200,000 operations at 690Vac. The rated voltage (AC) for phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1DFKG7 Schneider Electric LC1DFKG7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 120Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 normally open (NO) auxiliary contact and 2 normally closed (NC) auxiliary contacts, with the contacts type being 1NO+2NC instantaneous auxiliaries. The LC1DFKG7 has an electrical durability of 300,000 operations at 400Vac and 200,000 operations at 690Vac, with a rated impulse voltage (Uimp) of 6 kV and a phase-to-phase rated voltage (AC) of 690 V. | Schneider Electric | Quick Quote | |||
LC1D806U7 Schneider Electric LC1D806U7 is a magnetic contactor from the Deca sub-range, designed for ring-lugs connections. This 3-pole (3NO) contactor supports a rated current of 125A for AC-1 applications and 80A for 440Vac AC-3 applications. It is suitable for DIN rail mounting and has a net width of 85 mm. The LC1D806U7 offers a degree of protection rated at IP20 and operates with a control voltage (AC) range of 192-264Vac (240Vac nominal; 50Hz; 0.8...1.1 x Uc) and 204-264Vac (240Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is up to 1000 V, and it features 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 8 kV. This contactor can handle rated active power ranging from 22kW at 220-230Vac to 55kW at 500Vac in AC-3 applications, and it supports rated power in horsepower (HP) from 7.5HP at 115Vac to 60HP at 575-600Vac, covering both single-phase and 3-phase applications under UL/CSA standards. It boasts a mechanical durability of 4,000,000 operations and an electrical durability of 1,500,000 operations with load, ensuring a robust performance for a wide range of industrial applications. The rated voltage for phase-to-phase applications is 1000 V. | Schneider Electric | Quick Quote | |||
LC1D80008M6 Schneider Electric LC1D80008M6 is a magnetic contactor from the Deca sub-range, featuring screw connections and a 4-pole (2NO+2NC) configuration. It has a rated current of 125A (AC-1) and is designed for DIN rail mounting. The net width of the contactor is 96 mm, and it offers a degree of protection of IP20. The control voltage (AC) ranges from 187-242Vac (220Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. This model includes 0 normally open (NO) auxiliary contacts and 0 normally closed (NC) auxiliary contacts. It is capable of withstanding a rated impulse voltage (Uimp) of 8 kV and has a mechanical durability of 4,000,000 operations at no load. The rated voltage (AC) for phase-to-phase is 1000 V. | Schneider Electric | Quick Quote | |||
LC1D65ASC7 Schneider Electric LC1D65ASC7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 65A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 460-632Vac at 50Hz and 489-632Vac at 60Hz, with a nominal control voltage of 575Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65ASC7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1D65A3G7 Schneider Electric LC1D65A3G7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor is designed for a rated current of 80A under AC-1 conditions and 65A at 440Vac under AC-3 conditions. It supports DIN rail mounting and has a net width of 55 mm. The LC1D65A3G7 offers an IP20 degree of protection and operates with a control voltage of 96-132Vac at 50Hz and 102-132Vac at 60Hz. Its rated operating voltage (Ue) reaches up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 18.5kW at 220-230Vac to 37kW at 660-690Vac under AC-3 conditions. It also supports various rated power (HP) levels for different voltages and phases, including 5HP at 115Vac single-phase and up to 50HP at 575-600Vac three-phase, according to UL/CSA standards. The mechanical durability of the LC1D65A3G7 is rated at 6 million operations, and its electrical durability with load is 1.4 million operations. The rated voltage for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1D50AND Schneider Electric LC1D50AND is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 80A for AC-1 and 50A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 45-75Vdc, with a nominal value of 60Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. This contactor supports rated active power from 15kW at 220-230Vac to 33kW at 660-690Vac in AC-3, and it has both 1NO+1NC instantaneous auxiliary contacts. The rated power in horsepower (HP) varies from 3HP at 115Vac to 40HP at 575-600Vac, suitable for both single-phase and 3-phase systems. It boasts a mechanical durability of 6 million operations and an electrical durability of 1.45 million operations with load, with a phase-to-phase rated voltage of 690 V. | Schneider Electric | Quick Quote | |||
LC1D50A3T7 Schneider Electric LC1D50A3T7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for connection. It is equipped with spring connections for control and screw connections for power, and it operates with 3 poles (3P; 3NO). This contactor is designed for a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It supports DIN rail mounting and has a net width of 55 mm. The LC1D50A3T7 offers a degree of protection rated at IP20 and operates with a control voltage range of 384-528Vac at 50Hz and 408-528Vac at 60Hz, with a nominal control voltage of 480Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor can handle rated active power ranging from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. It also supports various rated power (HP) settings for different voltages and phases under UL/CSA standards, including 3HP at 115Vac and up to 40HP at 575-600Vac. The mechanical durability of the LC1D50A3T7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.45 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote |