All categories
Contactors
All categories
Contactors
Schneider Electric LC1D40ACD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) device with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). This contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) of 27-45Vdc (36Vdc nom.; 0.75...1.25 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. It also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac to 30HP at 575-600Vac, covering both single-phase and 3-phase applications. The mechanical durability of the LC1D40ACD is rated at 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) for phase-to-phase applications is 690 V.
Quick Quote
Schneider Electric LC1D098JD is a magnetic contactor within the Deca sub-range, featuring screw connections and designed with 4 poles (2NO+2NC). It has a rated current of 20A under AC-1 conditions and is suitable for DIN rail mounting. The dimensions include a net width of 45 mm, and it offers a degree of protection rated at IP20. This contactor operates with a control voltage (DC) range of 9-15Vdc, with a nominal value of 12Vdc, and can handle a rated operating voltage (Ue) up to 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both rated for instantaneous operation. The contacts type is specified as 1NO+1NC instantaneous aux. It boasts a mechanical durability of 15,000,000 operations at no load and can withstand a rated impulse voltage (Uimp) of 6 kV. The rated voltage for phase-to-phase connections is specified at 690 V.
Quick Quote
Schneider Electric LP4K0601EW3 is a magnetic contactor from the K sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 6A at 440Vac under AC-3 conditions and offers a degree of protection of IP20. The control voltage (DC) ranges from 33.6-62.4Vdc, with a nominal value of 48Vdc, equivalent to 0.7...1.3 times the control voltage (Uc). The rated operating voltage (Ue) is up to 690 V. This model includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. It supports rated active power of 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. The mechanical durability of the LP4K0601EW3 is rated at 30 million operations at no load, with a phase-to-phase rated voltage (AC) of 690 V and a power consumption of 1.8 W.
Quick Quote
Schneider Electric LP1K0910ZD is a magnetic contactor within the K sub-range, featuring screw connections and three poles (3P; 3NO). It has a rated current of 20A (AC-1) and 9A (440Vac; AC-3), with a net width of 45 mm. This contactor offers a degree of protection of IP20 and operates with a control voltage (DC) of 16-23Vdc (20Vdc nom.; 0.8...1.15 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 Normally Open (NO) auxiliary contact but no Normally Closed (NC) auxiliary contacts. The rated active power ranges from 2.2kW at 220-230Vac to 4kW at 660-690Vac, all within the AC-3 category. Its mechanical durability is rated at 10 million operations at no load, and the rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LP1K12017BD is a magnetic contactor within the K sub-range, featuring Faston spade connections for quick installation. This 3-pole (3P; 3NO) contactor is designed to handle rated currents of 20A under AC-1 conditions and 12A at 440Vac under AC-3 conditions. It has a net width of 45 mm and offers a degree of protection rated at IP20. The control voltage (DC) ranges from 19.2 to 27.6Vdc, with a nominal value of 24Vdc, corresponding to 0.8...1.15 times the control voltage (Uc). The rated operating voltage (Ue) reaches up to 690 V. This model includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. It supports rated active power of 3kW at 220-230Vac, 5.5kW at both 380-415Vac and 440Vac, 4kW at 500Vac, and 4kW at 660-690Vac, all under AC-3 conditions. The mechanical durability of this contactor is rated for 10,000,000 operations at no load, with a phase-to-phase rated voltage (AC) of 690 V.
Quick Quote
Schneider Electric LC2D65AK7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and a mechanical interlock. It has screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 65A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 80-110Vac (100Vac nominal; 50Hz; 0.8...1.1 x Uc) and 85-110Vac (100Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The contactor supports a rated active power (kW) of 18.5kW (220-230Vac; AC-3), 30kW (380-400Vac; AC-3), 37kW (415Vac; AC-3), 37kW (440Vac; AC-3), 37kW (500Vac; AC-3), and 37kW (660-690Vac; AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor and has a rated power (HP) of 5HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 10HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 20HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 20HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 40HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 50HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1DT80A6RD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and ring-lugs connections. This 4-pole (4P; 4NO) contactor is designed for a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 330-550Vdc (440Vdc nominal; 0.75...1.25 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous aux. The mechanical durability of this contactor is rated at 6,000,000 operations at no load, and it can handle a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase connections is up to 690 V.
Quick Quote
Schneider Electric LC1DT80A6G7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections and ring-lugs connection type. This 4-pole (4P; 4NO) contactor is designed for a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage for AC ranges from 96-132Vac at 50Hz and 102-132Vac at 60Hz, with a nominal voltage of 120Vac. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV, and it has a mechanical durability of 6 million operations at no load. The rated voltage for AC phase-to-phase is up to 690 V.
Quick Quote
Schneider Electric LC1DT60AFC7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges from 102-139Vac at 50Hz (127Vac nominal; 0.8...1.1 x Uc) to 108-139Vac at 60Hz (127Vac nominal; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The LC1DT60AFC7 is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. The rated voltage (AC) for phase-to-phase connections is up to 690 V.
Quick Quote
Schneider Electric LC1DT60A3V7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, ensuring a robust connection system. This 4-pole (4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. With a net width of 70 mm and an IP20 degree of protection, it is compact and offers basic protection against touch. The control voltage ranges from 320-440Vac at 50Hz and 340-440Vac at 60Hz, with a nominal voltage of 400Vac. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both rated for instantaneous operation. The contactor is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. The rated voltage for phase-to-phase connections is up to 690 V.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LC1D40ACD Schneider Electric LC1D40ACD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) device with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). This contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) of 27-45Vdc (36Vdc nom.; 0.75...1.25 x Uc). The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power ranges from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3 category. It also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac to 30HP at 575-600Vac, covering both single-phase and 3-phase applications. The mechanical durability of the LC1D40ACD is rated at 6,000,000 operations, and its electrical durability with load is 1,500,000 operations. The rated voltage (AC) for phase-to-phase applications is 690 V. | Schneider Electric | Quick Quote | |||
LC1D098JD Schneider Electric LC1D098JD is a magnetic contactor within the Deca sub-range, featuring screw connections and designed with 4 poles (2NO+2NC). It has a rated current of 20A under AC-1 conditions and is suitable for DIN rail mounting. The dimensions include a net width of 45 mm, and it offers a degree of protection rated at IP20. This contactor operates with a control voltage (DC) range of 9-15Vdc, with a nominal value of 12Vdc, and can handle a rated operating voltage (Ue) up to 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both rated for instantaneous operation. The contacts type is specified as 1NO+1NC instantaneous aux. It boasts a mechanical durability of 15,000,000 operations at no load and can withstand a rated impulse voltage (Uimp) of 6 kV. The rated voltage for phase-to-phase connections is specified at 690 V. | Schneider Electric | Quick Quote | |||
LP4K0601EW3 Schneider Electric LP4K0601EW3 is a magnetic contactor from the K sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 6A at 440Vac under AC-3 conditions and offers a degree of protection of IP20. The control voltage (DC) ranges from 33.6-62.4Vdc, with a nominal value of 48Vdc, equivalent to 0.7...1.3 times the control voltage (Uc). The rated operating voltage (Ue) is up to 690 V. This model includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. It supports rated active power of 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. The mechanical durability of the LP4K0601EW3 is rated at 30 million operations at no load, with a phase-to-phase rated voltage (AC) of 690 V and a power consumption of 1.8 W. | Schneider Electric | Quick Quote | |||
LP1K0910ZD Schneider Electric LP1K0910ZD is a magnetic contactor within the K sub-range, featuring screw connections and three poles (3P; 3NO). It has a rated current of 20A (AC-1) and 9A (440Vac; AC-3), with a net width of 45 mm. This contactor offers a degree of protection of IP20 and operates with a control voltage (DC) of 16-23Vdc (20Vdc nom.; 0.8...1.15 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 1 Normally Open (NO) auxiliary contact but no Normally Closed (NC) auxiliary contacts. The rated active power ranges from 2.2kW at 220-230Vac to 4kW at 660-690Vac, all within the AC-3 category. Its mechanical durability is rated at 10 million operations at no load, and the rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LP1K12017BD Schneider Electric LP1K12017BD is a magnetic contactor within the K sub-range, featuring Faston spade connections for quick installation. This 3-pole (3P; 3NO) contactor is designed to handle rated currents of 20A under AC-1 conditions and 12A at 440Vac under AC-3 conditions. It has a net width of 45 mm and offers a degree of protection rated at IP20. The control voltage (DC) ranges from 19.2 to 27.6Vdc, with a nominal value of 24Vdc, corresponding to 0.8...1.15 times the control voltage (Uc). The rated operating voltage (Ue) reaches up to 690 V. This model includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. It supports rated active power of 3kW at 220-230Vac, 5.5kW at both 380-415Vac and 440Vac, 4kW at 500Vac, and 4kW at 660-690Vac, all under AC-3 conditions. The mechanical durability of this contactor is rated for 10,000,000 operations at no load, with a phase-to-phase rated voltage (AC) of 690 V. | Schneider Electric | Quick Quote | |||
LC2D65AK7 Schneider Electric LC2D65AK7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and a mechanical interlock. It has screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 65A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 80-110Vac (100Vac nominal; 50Hz; 0.8...1.1 x Uc) and 85-110Vac (100Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The contactor supports a rated active power (kW) of 18.5kW (220-230Vac; AC-3), 30kW (380-400Vac; AC-3), 37kW (415Vac; AC-3), 37kW (440Vac; AC-3), 37kW (500Vac; AC-3), and 37kW (660-690Vac; AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor and has a rated power (HP) of 5HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 10HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 20HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 20HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 40HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 50HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1DT80A6RD Schneider Electric LC1DT80A6RD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and ring-lugs connections. This 4-pole (4P; 4NO) contactor is designed for a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 330-550Vdc (440Vdc nominal; 0.75...1.25 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous aux. The mechanical durability of this contactor is rated at 6,000,000 operations at no load, and it can handle a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase connections is up to 690 V. | Schneider Electric | Quick Quote | |||
LC1DT80A6G7 Schneider Electric LC1DT80A6G7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections and ring-lugs connection type. This 4-pole (4P; 4NO) contactor is designed for a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage for AC ranges from 96-132Vac at 50Hz and 102-132Vac at 60Hz, with a nominal voltage of 120Vac. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV, and it has a mechanical durability of 6 million operations at no load. The rated voltage for AC phase-to-phase is up to 690 V. | Schneider Electric | Quick Quote | |||
LC1DT60AFC7 Schneider Electric LC1DT60AFC7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges from 102-139Vac at 50Hz (127Vac nominal; 0.8...1.1 x Uc) to 108-139Vac at 60Hz (127Vac nominal; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The LC1DT60AFC7 is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. The rated voltage (AC) for phase-to-phase connections is up to 690 V. | Schneider Electric | Quick Quote | |||
LC1DT60A3V7 Schneider Electric LC1DT60A3V7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, ensuring a robust connection system. This 4-pole (4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. With a net width of 70 mm and an IP20 degree of protection, it is compact and offers basic protection against touch. The control voltage ranges from 320-440Vac at 50Hz and 340-440Vac at 60Hz, with a nominal voltage of 400Vac. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both rated for instantaneous operation. The contactor is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. The rated voltage for phase-to-phase connections is up to 690 V. | Schneider Electric | Quick Quote |