All categories
Contactors
All categories
Contactors
Schneider Electric LP1K0901GD is a magnetic contactor from the K sub-range, designed with screw connections and equipped with 3 poles (3P; 3NO). It has a rated current of 20A under AC-1 conditions and 9A at 440Vac under AC-3 conditions. The contactor's net width is 45 mm and it offers a degree of protection of IP20. The control voltage (DC) ranges from 100-143Vdc, with a nominal value of 125Vdc, corresponding to 0.8...1.15 times the control voltage (Uc). It operates at a rated operating voltage (Ue) of up to 690 V and includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated active power varies with voltage, providing 2.2kW at 220-230Vac, and 4kW at 380-415Vac, 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. Its mechanical durability at no load is rated for 10,000,000 operations, and the rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LP1K09017BD is a magnetic contactor within the K sub-range, featuring Faston spade connections and three poles (3P; 3NO). It has a rated current of 20A for AC-1 and 9A for 440Vac in AC-3. The net width of the contactor is 45 mm, and it offers a degree of protection of IP20. The control voltage (DC) ranges from 19.2 to 27.6Vdc, with a nominal value of 24Vdc (0.8...1.15 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it comes with 0 Normally Open (NO) auxiliary contacts and 1 Normally Closed (NC) auxiliary contact. The rated active power varies from 2.2kW at 220-230Vac to 4kW at 660-690Vac in AC-3. The mechanical durability of the contactor is rated at 10 million operations at no load, and the rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LP1D65008ED is a magnetic contactor from the Deca sub-range, designed with screw connections and featuring 4 poles (2NO+2NC). It has a rated current of 80A (AC-1), a net width of 85 mm, and offers a degree of protection of IP20. The control voltage (DC) ranges from 40.8 to 52.8Vdc, with a nominal value of 48Vdc (0.85...1.1 x Uc). This contactor is capable of operating at a rated operating voltage (Ue) of 690 V and a rated impulse voltage (Uimp) of 8 kV. It has no normally open (NO) or normally closed (NC) auxiliary contacts. Its mechanical durability is rated at 15,000,000 operations at no load, and it supports a rated voltage (AC) for phase-to-phase connections of 690 V.
Quick Quote
Schneider Electric LC2K12105B7 is a pre-assembled reversing magnetic contactor within the K sub-range, featuring a mechanical interlock for standard applications. It is equipped with solder pins connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 20A (AC-1) and 12A (440Vac; AC-3). This contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 19.2-27.6Vac (24Vac nom.; 50Hz/60Hz; 0.8...1.15 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts without Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV, and the rated active power (kW) ranges from 3kW at 220-230Vac to 5.5kW at 440Vac in AC-3 category. The contactor's contacts type is 1NO (contactor A) + 1NO (contactor B), and it has a mechanical durability of 5 million operations at no load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC2K0601R7 is a pre-assembled reversing magnetic contactor designed for standard applications, featuring a mechanical interlock. It comes with screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 6A at 440Vac under AC-3 utilization category. This contactor offers a degree of protection of IP20 and operates with a control voltage (AC) range of 352-506Vac (440Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc). The rated operating voltage (Ue) is 690 V, and it has 0 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with contact types of 1NC (contactor A) + 1NC (contactor B). The rated impulse voltage (Uimp) is 8 kV, and it supports rated active power (kW) of 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3. Its mechanical durability is rated at 5,000,000 operations at no load, and the rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1K0601S7 is a magnetic contactor within the K sub-range, featuring screw connections and three poles (3P; 3NO). It has a rated current of 20A under AC-1 conditions and 6A at 440Vac under AC-3 conditions. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 400-575Vac (500Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc), with a rated operating voltage (Ue) of 690 V. This model includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated impulse voltage (Uimp) is 8 kV. It supports rated active power of 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. The mechanical durability of the LC1K0601S7, at no load, is rated for 10,000,000 operations, and the rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1F780GD is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features ring-lugs/bar connections and is equipped with 3 poles (3P; 3NO). The contactor is rated for currents of 1600A (AC-1) and 780A (440Vac; AC-3), with a control voltage (DC) range of 107-137Vdc (125Vdc nom.; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 1000 V, and it has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) stands at 8 kV. It supports rated active power (kW) of 220kW (220-230Vac; AC-3), 400kW (380-400Vac; AC-3), 425kW (415Vac; AC-3), 425kW (440Vac; AC-3), 450kW (500Vac; AC-3), 475kW (660-690Vac; AC-3), and 450kW (1000Vac; AC-3). The mechanical durability of the LC1F780GD, at no load, is rated for 5,000,000 operations, and the rated voltage (AC) for phase-to-phase connections is 1000 V.
Quick Quote
Schneider Electric LC1F2654BD is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 4-pole (4P; 4NO) configuration and supports ring-lugs/bar connections. This contactor is rated for a current of 350A under AC-1 conditions and operates with a control voltage range of 20.4-26.4Vdc, with a nominal 24Vdc. The rated operating voltage (Ue) and the rated voltage (AC) for phase-to-phase connections are both 1000 V. It has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV, and it boasts a mechanical durability of 10 million operations at no load.
Quick Quote
Schneider Electric LC1F185GD is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration and supports ring-lugs/bar connections. The contactor is rated for currents of 275A under AC-1 conditions and 185A at 440Vac under AC-3 conditions. It operates with a control voltage (DC) range of 107-137Vdc, with a nominal value of 125Vdc, and can handle a rated operating voltage (Ue) up to 1000 V. The LC1F185GD does not include normally open (NO) or normally closed (NC) auxiliary contacts. It is capable of switching rated active power loads of up to 55kW at 220-230Vac, 90kW at 380-400Vac, 100kW at both 415Vac and 440Vac, 110kW at 500Vac, and 660-690Vac, and 100kW at 1000Vac, all under AC-3 conditions. The rated impulse voltage (Uimp) is 8 kV, and it boasts a mechanical durability of 10 million operations at no load. The rated voltage for phase-to-phase applications is 1000 V.
Quick Quote
Schneider Electric LC1DT80A6UD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for secure connections. It is equipped with ring-lugs connections and has 4 poles (4P; 4NO) with a rated current of 80A (AC-1). This contactor is designed for DIN rail mounting and has a net width of 70 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc). The LC1DT80A6UD includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). It is rated for an impulse voltage (Uimp) of 6 kV and mechanical durability of 6,000,000 operations at no load. The rated voltage (AC) for phase-to-phase connections is up to 690 V.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LP1K0901GD Schneider Electric LP1K0901GD is a magnetic contactor from the K sub-range, designed with screw connections and equipped with 3 poles (3P; 3NO). It has a rated current of 20A under AC-1 conditions and 9A at 440Vac under AC-3 conditions. The contactor's net width is 45 mm and it offers a degree of protection of IP20. The control voltage (DC) ranges from 100-143Vdc, with a nominal value of 125Vdc, corresponding to 0.8...1.15 times the control voltage (Uc). It operates at a rated operating voltage (Ue) of up to 690 V and includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated active power varies with voltage, providing 2.2kW at 220-230Vac, and 4kW at 380-415Vac, 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. Its mechanical durability at no load is rated for 10,000,000 operations, and the rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LP1K09017BD Schneider Electric LP1K09017BD is a magnetic contactor within the K sub-range, featuring Faston spade connections and three poles (3P; 3NO). It has a rated current of 20A for AC-1 and 9A for 440Vac in AC-3. The net width of the contactor is 45 mm, and it offers a degree of protection of IP20. The control voltage (DC) ranges from 19.2 to 27.6Vdc, with a nominal value of 24Vdc (0.8...1.15 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it comes with 0 Normally Open (NO) auxiliary contacts and 1 Normally Closed (NC) auxiliary contact. The rated active power varies from 2.2kW at 220-230Vac to 4kW at 660-690Vac in AC-3. The mechanical durability of the contactor is rated at 10 million operations at no load, and the rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LP1D65008ED Schneider Electric LP1D65008ED is a magnetic contactor from the Deca sub-range, designed with screw connections and featuring 4 poles (2NO+2NC). It has a rated current of 80A (AC-1), a net width of 85 mm, and offers a degree of protection of IP20. The control voltage (DC) ranges from 40.8 to 52.8Vdc, with a nominal value of 48Vdc (0.85...1.1 x Uc). This contactor is capable of operating at a rated operating voltage (Ue) of 690 V and a rated impulse voltage (Uimp) of 8 kV. It has no normally open (NO) or normally closed (NC) auxiliary contacts. Its mechanical durability is rated at 15,000,000 operations at no load, and it supports a rated voltage (AC) for phase-to-phase connections of 690 V. | Schneider Electric | Quick Quote | |||
LC2K12105B7 Schneider Electric LC2K12105B7 is a pre-assembled reversing magnetic contactor within the K sub-range, featuring a mechanical interlock for standard applications. It is equipped with solder pins connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 20A (AC-1) and 12A (440Vac; AC-3). This contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 19.2-27.6Vac (24Vac nom.; 50Hz/60Hz; 0.8...1.15 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts without Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV, and the rated active power (kW) ranges from 3kW at 220-230Vac to 5.5kW at 440Vac in AC-3 category. The contactor's contacts type is 1NO (contactor A) + 1NO (contactor B), and it has a mechanical durability of 5 million operations at no load. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC2K0601R7 Schneider Electric LC2K0601R7 is a pre-assembled reversing magnetic contactor designed for standard applications, featuring a mechanical interlock. It comes with screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 6A at 440Vac under AC-3 utilization category. This contactor offers a degree of protection of IP20 and operates with a control voltage (AC) range of 352-506Vac (440Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc). The rated operating voltage (Ue) is 690 V, and it has 0 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with contact types of 1NC (contactor A) + 1NC (contactor B). The rated impulse voltage (Uimp) is 8 kV, and it supports rated active power (kW) of 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3. Its mechanical durability is rated at 5,000,000 operations at no load, and the rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1K0601S7 Schneider Electric LC1K0601S7 is a magnetic contactor within the K sub-range, featuring screw connections and three poles (3P; 3NO). It has a rated current of 20A under AC-1 conditions and 6A at 440Vac under AC-3 conditions. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 400-575Vac (500Vac nominal; 50Hz/60Hz; 0.8...1.15 x Uc), with a rated operating voltage (Ue) of 690 V. This model includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated impulse voltage (Uimp) is 8 kV. It supports rated active power of 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. The mechanical durability of the LC1K0601S7, at no load, is rated for 10,000,000 operations, and the rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1F780GD Schneider Electric LC1F780GD is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features ring-lugs/bar connections and is equipped with 3 poles (3P; 3NO). The contactor is rated for currents of 1600A (AC-1) and 780A (440Vac; AC-3), with a control voltage (DC) range of 107-137Vdc (125Vdc nom.; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 1000 V, and it has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) stands at 8 kV. It supports rated active power (kW) of 220kW (220-230Vac; AC-3), 400kW (380-400Vac; AC-3), 425kW (415Vac; AC-3), 425kW (440Vac; AC-3), 450kW (500Vac; AC-3), 475kW (660-690Vac; AC-3), and 450kW (1000Vac; AC-3). The mechanical durability of the LC1F780GD, at no load, is rated for 5,000,000 operations, and the rated voltage (AC) for phase-to-phase connections is 1000 V. | Schneider Electric | Quick Quote | |||
LC1F2654BD Schneider Electric LC1F2654BD is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 4-pole (4P; 4NO) configuration and supports ring-lugs/bar connections. This contactor is rated for a current of 350A under AC-1 conditions and operates with a control voltage range of 20.4-26.4Vdc, with a nominal 24Vdc. The rated operating voltage (Ue) and the rated voltage (AC) for phase-to-phase connections are both 1000 V. It has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV, and it boasts a mechanical durability of 10 million operations at no load. | Schneider Electric | Quick Quote | |||
LC1F185GD Schneider Electric LC1F185GD is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration and supports ring-lugs/bar connections. The contactor is rated for currents of 275A under AC-1 conditions and 185A at 440Vac under AC-3 conditions. It operates with a control voltage (DC) range of 107-137Vdc, with a nominal value of 125Vdc, and can handle a rated operating voltage (Ue) up to 1000 V. The LC1F185GD does not include normally open (NO) or normally closed (NC) auxiliary contacts. It is capable of switching rated active power loads of up to 55kW at 220-230Vac, 90kW at 380-400Vac, 100kW at both 415Vac and 440Vac, 110kW at 500Vac, and 660-690Vac, and 100kW at 1000Vac, all under AC-3 conditions. The rated impulse voltage (Uimp) is 8 kV, and it boasts a mechanical durability of 10 million operations at no load. The rated voltage for phase-to-phase applications is 1000 V. | Schneider Electric | Quick Quote | |||
LC1DT80A6UD Schneider Electric LC1DT80A6UD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for secure connections. It is equipped with ring-lugs connections and has 4 poles (4P; 4NO) with a rated current of 80A (AC-1). This contactor is designed for DIN rail mounting and has a net width of 70 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc). The LC1DT80A6UD includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). It is rated for an impulse voltage (Uimp) of 6 kV and mechanical durability of 6,000,000 operations at no load. The rated voltage (AC) for phase-to-phase connections is up to 690 V. | Schneider Electric | Quick Quote |