Found 996 products

Schneider Electric

Schneider Electric LC1F1854ED is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 4-pole (4P; 4NO) configuration and supports a rated current of 275A under AC-1 conditions. This contactor is equipped with ring-lugs/bar connections for installation and operates with a control voltage range of 40.8-52.8Vdc, with a nominal value of 48Vdc (0.85...1.1 x Uc). The rated operating voltage (Ue) and the rated voltage (AC) for phase-to-phase applications are both 1000 V. It has a rated impulse voltage (Uimp) of 8 kV. The LC1F1854ED does not include normally open (NO) or normally closed (NC) auxiliary contacts. Its mechanical durability is rated at 10,000,000 operations at no load, ensuring a long service life for high-demand applications.

Quick Quote

Schneider Electric

Schneider Electric LC1F115FD is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration with ring-lugs/bar connections for electrical interfacing. The contactor is rated for currents up to 200A in AC-1 applications and 115A at 440Vac in AC-3 scenarios. Control voltage for the device is specified at 93.5-121Vdc, with a nominal value of 110Vdc, corresponding to 0.85...1.1 times the control voltage (Uc). The rated operating voltage (Ue) reaches up to 1000 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV. It supports rated active power (kW) across various voltages, including 30kW at 220-230Vac, 55kW at 380-400Vac, 59kW at both 415Vac and 440Vac, 75kW at 500Vac, 80kW at 660-690Vac, and 65kW at 1000Vac in AC-3 applications. The mechanical durability of the LC1F115FD, at no load, is rated for 10,000,000 operations, and the phase-to-phase rated voltage (AC) is 1000 V.

Quick Quote

Schneider Electric

Schneider Electric LC1F1154FD is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 4-pole (4P; 4NO) configuration and supports a rated current of 200A under AC-1 conditions. This contactor offers ring-lugs/bar connections for ease of installation and is compatible with a control voltage (DC) range of 93.5-121Vdc, with a nominal value of 110Vdc (0.85...1.1 x Uc). The LC1F1154FD operates at a rated operating voltage (Ue) of 1000 V and a phase-to-phase rated voltage (AC) of 1000 V, ensuring compatibility with high-voltage applications. It has a rated impulse voltage (Uimp) of 8 kV and is equipped with 0 Normally Open (NO) and 0 Normally Closed (NC) auxiliary contacts. The mechanical durability of this contactor is rated at 10 million operations at no load, highlighting its capability for extensive use.

Quick Quote

Schneider Electric

Schneider Electric LC1DWK12E7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 48Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+2NC instantaneous auxiliaries. The LC1DWK12E7 has a rated impulse voltage (Uimp) of 6 kV and demonstrates electrical durability with a load of 300,000 operations at 400Vac and 200,000 operations at 690Vac. The rated voltage (AC) for phase-to-phase is 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC1DTKG7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 120Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+2NC instantaneous auxiliaries. The LC1DTKG7 has an electrical durability of 300,000 operations at 400Vac and 200,000 operations at 690Vac, with a rated impulse voltage (Uimp) of 6 kV and a phase-to-phase rated voltage (AC) of 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC1DT80AUD is a magnetic contactor within the Deca sub-range, featuring EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage (DC) ranges from 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc), with a rated operating voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both types being instantaneous (1NO+1NC). The LC1DT80AUD is capable of withstanding rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. The rated voltage (AC) for phase-to-phase connections is 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC1DT80AV7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for screw connections. This 4-pole (4P; 4NO) contactor is rated for 80A (AC-1) and is designed for DIN rail mounting. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 320-440Vac (400Vac nominal; 50Hz; 0.8...1.1 x Uc) to 340-440Vac (400Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+1NC instantaneous auxiliaries. The mechanical durability of this contactor is rated at 6,000,000 operations at no load, and it has a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase connections is 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC1DT80AS7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for screw connections. This 4-pole (4P; 4NO) contactor is rated for 80A (AC-1) and is designed for DIN rail mounting. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges between 400-550Vac (500Vac nominal; 50Hz; 0.8...1.1 x Uc) and 425-550Vac (500Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The LC1DT80AS7 has a mechanical durability of 6,000,000 operations at no load, a rated impulse voltage (Uimp) of 6 kV, and a rated voltage (AC) for phase-to-phase of 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC1DT80A6T7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 4-pole (4P; 4NO) contactor is designed for a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage for AC ranges from 384-528Vac (480Vac nominal; 50Hz; 0.8...1.1 x Uc) to 408-528Vac (480Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous auxiliaries. The rated impulse voltage (Uimp) is 6 kV, and it has a mechanical durability of 6,000,000 operations at no load. The rated voltage (AC) phase-to-phase is 690 V.

Quick Quote

Schneider Electric

Schneider Electric LC1DT80A6S7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 4-pole (4NO) contactor is designed for a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage for AC ranges between 400-550Vac (500Vac nominal; 50Hz; 0.8...1.1 x Uc) and 425-550Vac (500Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous aux. The LC1DT80A6S7 is rated for an impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. Its rated voltage for AC phase-to-phase is 690 V.

Quick Quote

ItemManufacturerPriceStockDelivery

LC1F1854ED

Schneider Electric LC1F1854ED is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 4-pole (4P; 4NO) configuration and supports a rated current of 275A under AC-1 conditions. This contactor is equipped with ring-lugs/bar connections for installation and operates with a control voltage range of 40.8-52.8Vdc, with a nominal value of 48Vdc (0.85...1.1 x Uc). The rated operating voltage (Ue) and the rated voltage (AC) for phase-to-phase applications are both 1000 V. It has a rated impulse voltage (Uimp) of 8 kV. The LC1F1854ED does not include normally open (NO) or normally closed (NC) auxiliary contacts. Its mechanical durability is rated at 10,000,000 operations at no load, ensuring a long service life for high-demand applications.

Schneider Electric

Quick Quote

LC1F115FD

Schneider Electric LC1F115FD is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration with ring-lugs/bar connections for electrical interfacing. The contactor is rated for currents up to 200A in AC-1 applications and 115A at 440Vac in AC-3 scenarios. Control voltage for the device is specified at 93.5-121Vdc, with a nominal value of 110Vdc, corresponding to 0.85...1.1 times the control voltage (Uc). The rated operating voltage (Ue) reaches up to 1000 V, and it has no normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV. It supports rated active power (kW) across various voltages, including 30kW at 220-230Vac, 55kW at 380-400Vac, 59kW at both 415Vac and 440Vac, 75kW at 500Vac, 80kW at 660-690Vac, and 65kW at 1000Vac in AC-3 applications. The mechanical durability of the LC1F115FD, at no load, is rated for 10,000,000 operations, and the phase-to-phase rated voltage (AC) is 1000 V.

Schneider Electric

Quick Quote

LC1F1154FD

Schneider Electric LC1F1154FD is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 4-pole (4P; 4NO) configuration and supports a rated current of 200A under AC-1 conditions. This contactor offers ring-lugs/bar connections for ease of installation and is compatible with a control voltage (DC) range of 93.5-121Vdc, with a nominal value of 110Vdc (0.85...1.1 x Uc). The LC1F1154FD operates at a rated operating voltage (Ue) of 1000 V and a phase-to-phase rated voltage (AC) of 1000 V, ensuring compatibility with high-voltage applications. It has a rated impulse voltage (Uimp) of 8 kV and is equipped with 0 Normally Open (NO) and 0 Normally Closed (NC) auxiliary contacts. The mechanical durability of this contactor is rated at 10 million operations at no load, highlighting its capability for extensive use.

Schneider Electric

Quick Quote

LC1DWK12E7

Schneider Electric LC1DWK12E7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 48Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+2NC instantaneous auxiliaries. The LC1DWK12E7 has a rated impulse voltage (Uimp) of 6 kV and demonstrates electrical durability with a load of 300,000 operations at 400Vac and 200,000 operations at 690Vac. The rated voltage (AC) for phase-to-phase is 690 V.

Schneider Electric

Quick Quote

LC1DTKG7

Schneider Electric LC1DTKG7 is a magnetic contactor from the Deca sub-range designed for capacitor switching duty. It features screw connections and is equipped with three poles (3P; 3NO) for mounting on a DIN rail. This contactor offers a degree of protection rated at IP20 and operates with a control voltage (AC) of 120Vac (50Hz/60Hz). The rated operating voltage (Ue) is 690 V, and it includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+2NC instantaneous auxiliaries. The LC1DTKG7 has an electrical durability of 300,000 operations at 400Vac and 200,000 operations at 690Vac, with a rated impulse voltage (Uimp) of 6 kV and a phase-to-phase rated voltage (AC) of 690 V.

Schneider Electric

Quick Quote

LC1DT80AUD

Schneider Electric LC1DT80AUD is a magnetic contactor within the Deca sub-range, featuring EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage (DC) ranges from 187.5-312.5Vdc (250Vdc nominal; 0.75...1.25 x Uc), with a rated operating voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both types being instantaneous (1NO+1NC). The LC1DT80AUD is capable of withstanding rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. The rated voltage (AC) for phase-to-phase connections is 690 V.

Schneider Electric

Quick Quote

LC1DT80AV7

Schneider Electric LC1DT80AV7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for screw connections. This 4-pole (4P; 4NO) contactor is rated for 80A (AC-1) and is designed for DIN rail mounting. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 320-440Vac (400Vac nominal; 50Hz; 0.8...1.1 x Uc) to 340-440Vac (400Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+1NC instantaneous auxiliaries. The mechanical durability of this contactor is rated at 6,000,000 operations at no load, and it has a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase connections is 690 V.

Schneider Electric

Quick Quote

LC1DT80AS7

Schneider Electric LC1DT80AS7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design for screw connections. This 4-pole (4P; 4NO) contactor is rated for 80A (AC-1) and is designed for DIN rail mounting. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges between 400-550Vac (500Vac nominal; 50Hz; 0.8...1.1 x Uc) and 425-550Vac (500Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The LC1DT80AS7 has a mechanical durability of 6,000,000 operations at no load, a rated impulse voltage (Uimp) of 6 kV, and a rated voltage (AC) for phase-to-phase of 690 V.

Schneider Electric

Quick Quote

LC1DT80A6T7

Schneider Electric LC1DT80A6T7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 4-pole (4P; 4NO) contactor is designed for a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage for AC ranges from 384-528Vac (480Vac nominal; 50Hz; 0.8...1.1 x Uc) to 408-528Vac (480Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous auxiliaries. The rated impulse voltage (Uimp) is 6 kV, and it has a mechanical durability of 6,000,000 operations at no load. The rated voltage (AC) phase-to-phase is 690 V.

Schneider Electric

Quick Quote

LC1DT80A6S7

Schneider Electric LC1DT80A6S7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 4-pole (4NO) contactor is designed for a rated current of 80A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage for AC ranges between 400-550Vac (500Vac nominal; 50Hz; 0.8...1.1 x Uc) and 425-550Vac (500Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous aux. The LC1DT80A6S7 is rated for an impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. Its rated voltage for AC phase-to-phase is 690 V.

Schneider Electric

Quick Quote