All categories
Automation components
All categories
Automation components
Schneider Electric LC1D326BL is a magnetic contactor from the Deca sub-range, featuring a low-consumption coil that consumes less than 2.4W. It is designed with ring-lugs connections and has three poles (3P; 3NO) with a rated current of 50A for AC-1 and 32A for 440Vac in AC-3. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 19.2-30Vdc, with a nominal 24Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV, and it can handle rated active power ranging from 7.5kW at 220-230Vac to 18.5kW at 660-690Vac in AC-3. It also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower varies from 2HP at 115Vac in single-phase to 25HP at 575-600Vac in three-phase, according to UL/CSA standards. Its mechanical durability is rated at 15 million operations at no load, and its electrical durability is rated at 1.6 million operations with load. The rated voltage (AC) phase-to-phase is 690 V, and its power consumption is specified at 2.4 W.
4 in stock
24 hours
Schneider Electric MG17444 is a Miniature Circuit Breaker (MCB) designed as a supplementary protector within the C60 UL1077 sub-range. This 2-pole MCB is rated for a current of 5A and has an operating voltage (Ue) of 480V. It features a short circuit breaking rating of 10kA AIR at 240Vac, 5kA AIR at 480Y/277Vac, and 10kA AIR at 125Vdc. Both poles are protected, and it utilizes a C tripping curve.
2 in stock
24 hours
Schneider Electric LC1D95G7 is a magnetic contactor from the Deca sub-range, featuring screw connections and three poles (3P; 3NO). It has a rated current of 125A (AC-1) and 95A (440Vac; AC-3), with a mounting mode designed for DIN rail installation. The net width of the contactor is 85 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 96-132Vac (120Vac nominal; 50Hz; 0.8...1.1 x Uc) to 102-132Vac (120Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 8 kV. Its rated active power (kW) spans from 25kW at 220-230Vac to 45kW at up to 440Vac, reaching 55kW at 500Vac, and maintaining 45kW at 660-690Vac and 1000Vac, all in AC-3 category. The rated power (HP) varies from 7.5HP at 115Vac in single-phase to 60HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D95G7 is rated at 4,000,000 operations, with an electrical durability (with load) of 1,200,000 operations. The rated voltage (AC) for phase-to-phase connections is 1000 V.
11 in stock
24 hours
Schneider Electric RXZE2M114M is a plug-in socket within the RXZ sub-range designed for a rated current of 10 A and an operational ambient air temperature range of -40 to +55 °C. It features a degree of protection classified as IP20 and is equipped with connector type terminals. The socket is specified for a rated voltage (AC) of 250 V, phase-to-neutral.
8 in stock
24 hours
Schneider Electric M9F42235 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designed to comply with UL489 standards. This 2-pole MCB has a rated current of 35A and features a rated insulation voltage (Ui) of 500V. It is suitable for use with a rated voltage (DC) of 60Vdc and a rated impulse voltage (Uimp) of 6kV. The M9F42235 offers a short circuit breaking rating of 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 480Y/277Vac and 60Vdc. It supports a rated voltage (AC) of 240V phase-to-neutral and 415V phase-to-phase, with both poles protected. The tripping curve for this MCB is type C.
1 in stock
24 hours
Schneider Electric PKGTAB, Load center accessory, QO/Homeline, insulator kit, for ground bars
3 in stock
24 hours
Schneider Electric M9F23204 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed to provide circuit protection. This MCB features a 2-pole configuration with both poles protected, and it is rated for a current of 4A. It offers a short circuit breaking rating of 14kA AIR at 240Vac, and 10kA AIR at both 480Y/277Vac and 125Vdc. The M9F23204 is equipped with a D tripping curve, ensuring precise protection against overload and short-circuit conditions. This product is compliant with UL1077 standards for safety and performance.
3 in stock
24 hours
Square D by Schneider Electric HDF36070 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HDF sub-range, designed as a PowerPact H-Frame 150 TMD 3P 70A 600Vac/250Vdc with a 14kA busbar rated at 80%. It features a Term. nut kit for fixed busbar connection on both line and load sides, with three poles (3P). This MCCB offers thermal protection for overload and magnetic protection for short-circuit scenarios. It has a rated current of 70A, a rated insulation voltage (Ui) of 750 V, and operates at rated voltages of 600Vac 600Y/347Vac and 250Vdc. The unit is designed for individual mount on plate, with dimensions of 163 mm in height, 104 mm in width, and 86 mm in depth. It provides an IP40 degree of protection and operates via a toggle (manual) mode. Protection settings include over-current fixed at 70A, short-circuit hold current fixed at 800A, and short-circuit trip current fixed at 1450A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 70 AT, with a frame current rating of 150 AF. Its short circuit breaking rating varies with voltage, including 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display, and it falls under utilisation category A.
1 in stock
24 hours
Schneider Electric XB5AW34B5 is an illuminated flush push-button designed for automation control systems. This component, part of the XB5 sub-range, features a plastic body and bezel with a round shape and a plain lens type. It offers a degree of protection rated at IP66, making it suitable for use in environments where dust and water resistance are necessary. The push-button operates with a spring-return mechanism, providing momentary (impulse) activation. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for integration into various circuit designs. The XB5AW34B5 is equipped with an integral LED for illumination, with the light color being red. It operates on a supply voltage of 24 V, accommodating both AC and DC sources, and is compatible with network frequencies of 50/60 Hz. The diameter of the push-button is 22 mm, and it utilizes screw-clamp terminals for secure wire connections.
2 in stock
24 hours
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LC1D326BL Schneider Electric LC1D326BL is a magnetic contactor from the Deca sub-range, featuring a low-consumption coil that consumes less than 2.4W. It is designed with ring-lugs connections and has three poles (3P; 3NO) with a rated current of 50A for AC-1 and 32A for 440Vac in AC-3. This contactor is suitable for DIN rail mounting and has a net width of 45 mm. It offers a degree of protection of IP20 and operates with a control voltage (DC) range of 19.2-30Vdc, with a nominal 24Vdc. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV, and it can handle rated active power ranging from 7.5kW at 220-230Vac to 18.5kW at 660-690Vac in AC-3. It also features 1 normally closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower varies from 2HP at 115Vac in single-phase to 25HP at 575-600Vac in three-phase, according to UL/CSA standards. Its mechanical durability is rated at 15 million operations at no load, and its electrical durability is rated at 1.6 million operations with load. The rated voltage (AC) phase-to-phase is 690 V, and its power consumption is specified at 2.4 W. | Schneider Electric | $278.68 | 4 in stock | 24 hours | |
MG17444 Schneider Electric MG17444 is a Miniature Circuit Breaker (MCB) designed as a supplementary protector within the C60 UL1077 sub-range. This 2-pole MCB is rated for a current of 5A and has an operating voltage (Ue) of 480V. It features a short circuit breaking rating of 10kA AIR at 240Vac, 5kA AIR at 480Y/277Vac, and 10kA AIR at 125Vdc. Both poles are protected, and it utilizes a C tripping curve. | Schneider Electric | $218.00 | 2 in stock | 24 hours | |
LC1D95G7 Schneider Electric LC1D95G7 is a magnetic contactor from the Deca sub-range, featuring screw connections and three poles (3P; 3NO). It has a rated current of 125A (AC-1) and 95A (440Vac; AC-3), with a mounting mode designed for DIN rail installation. The net width of the contactor is 85 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 96-132Vac (120Vac nominal; 50Hz; 0.8...1.1 x Uc) to 102-132Vac (120Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 8 kV. Its rated active power (kW) spans from 25kW at 220-230Vac to 45kW at up to 440Vac, reaching 55kW at 500Vac, and maintaining 45kW at 660-690Vac and 1000Vac, all in AC-3 category. The rated power (HP) varies from 7.5HP at 115Vac in single-phase to 60HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D95G7 is rated at 4,000,000 operations, with an electrical durability (with load) of 1,200,000 operations. The rated voltage (AC) for phase-to-phase connections is 1000 V. | Schneider Electric | $437.00 | 11 in stock | 24 hours | |
RXZE2M114M Schneider Electric RXZE2M114M is a plug-in socket within the RXZ sub-range designed for a rated current of 10 A and an operational ambient air temperature range of -40 to +55 °C. It features a degree of protection classified as IP20 and is equipped with connector type terminals. The socket is specified for a rated voltage (AC) of 250 V, phase-to-neutral. | Schneider Electric | $6.10 | 8 in stock | 24 hours | |
M9F42235 Schneider Electric M9F42235 is a Miniature Circuit Breaker (MCB) within the C60BP sub-range, designed to comply with UL489 standards. This 2-pole MCB has a rated current of 35A and features a rated insulation voltage (Ui) of 500V. It is suitable for use with a rated voltage (DC) of 60Vdc and a rated impulse voltage (Uimp) of 6kV. The M9F42235 offers a short circuit breaking rating of 14kA AIR at both 120Vac and 240Vac, and 10kA AIR at 480Y/277Vac and 60Vdc. It supports a rated voltage (AC) of 240V phase-to-neutral and 415V phase-to-phase, with both poles protected. The tripping curve for this MCB is type C. | Schneider Electric | $257.00 | 1 in stock | 24 hours | |
PKGTAB Schneider Electric PKGTAB, Load center accessory, QO/Homeline, insulator kit, for ground bars | Schneider Electric | $30.76 | 3 in stock | 24 hours | |
M9F23204 Schneider Electric M9F23204 is a Miniature Circuit Breaker (MCB) within the C60SP sub-range, designed to provide circuit protection. This MCB features a 2-pole configuration with both poles protected, and it is rated for a current of 4A. It offers a short circuit breaking rating of 14kA AIR at 240Vac, and 10kA AIR at both 480Y/277Vac and 125Vdc. The M9F23204 is equipped with a D tripping curve, ensuring precise protection against overload and short-circuit conditions. This product is compliant with UL1077 standards for safety and performance. | Schneider Electric | $218.00 | 3 in stock | 24 hours | |
HDF36070 Square D by Schneider Electric HDF36070 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HDF sub-range, designed as a PowerPact H-Frame 150 TMD 3P 70A 600Vac/250Vdc with a 14kA busbar rated at 80%. It features a Term. nut kit for fixed busbar connection on both line and load sides, with three poles (3P). This MCCB offers thermal protection for overload and magnetic protection for short-circuit scenarios. It has a rated current of 70A, a rated insulation voltage (Ui) of 750 V, and operates at rated voltages of 600Vac 600Y/347Vac and 250Vdc. The unit is designed for individual mount on plate, with dimensions of 163 mm in height, 104 mm in width, and 86 mm in depth. It provides an IP40 degree of protection and operates via a toggle (manual) mode. Protection settings include over-current fixed at 70A, short-circuit hold current fixed at 800A, and short-circuit trip current fixed at 1450A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 70 AT, with a frame current rating of 150 AF. Its short circuit breaking rating varies with voltage, including 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display, and it falls under utilisation category A. | Schneider Electric | $1,328.00 | 1 in stock | 24 hours | |
XB5AW34B5 Schneider Electric XB5AW34B5 is an illuminated flush push-button designed for automation control systems. This component, part of the XB5 sub-range, features a plastic body and bezel with a round shape and a plain lens type. It offers a degree of protection rated at IP66, making it suitable for use in environments where dust and water resistance are necessary. The push-button operates with a spring-return mechanism, providing momentary (impulse) activation. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for integration into various circuit designs. The XB5AW34B5 is equipped with an integral LED for illumination, with the light color being red. It operates on a supply voltage of 24 V, accommodating both AC and DC sources, and is compatible with network frequencies of 50/60 Hz. The diameter of the push-button is 22 mm, and it utilizes screw-clamp terminals for secure wire connections. | Schneider Electric | $119.00 | 2 in stock | 24 hours | |
QOUR2205283 Schneider Electric - QOUR2205283 | Schneider Electric | $134.00 | 3 in stock | 24 hours |