Schneider Electric LR7K0322 is a non-differential thermal overload relay designed for unbalanced networks, classified under the LR7K sub-range. It features a 3-pole configuration and offers protection functions with Class 10A specifications. The relay supports a rated current range of 12-16 A and has protection settings for thermal overload within the same range. Connection types include direct to contactor for upstream connections and screw-clamp for both outgoing cables and the control circuit. It is equipped with 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The rated voltage for phase-to-phase connections is up to 690 V, with a minimum operating current of 12 A and a maximum of 16 A.
Quick Quote
Schneider Electric LR7K0306 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR7K sub-range. It features a 3-pole configuration and offers protection functions classified under Class 10A. The relay is designed for direct connection to a contactor upstream, with outgoing cables connected via screw-clamp and the control circuit also utilizing a screw-clamp connection type. It provides thermal overload protection settings adjustable between 0.8-1.2A. Additionally, it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The LR7K0306 is rated for a phase-to-phase voltage of up to 690 V AC, with a minimum operating current of 0.8 A and a maximum of 1.2 A.
Quick Quote
Schneider Electric LR3D3656 is a non-differential thermal overload relay designed for unbalanced networks, falling within the LR3D sub-range. It features a direct connection type to the contactor for upstream connections, with outgoing cables connected via lugs and a control circuit utilizing screw-clamp connections. This 3-pole relay is engineered for protection functions classified under Class 10A, with a rated current range of 48-65 A. The protection settings for thermal overload are adjustable between 48-65A. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The rated voltage for phase-to-phase connections is up to 690 V for frequencies ranging from 0 to 400Hz. The minimum current specification is 48 A, and it can handle a maximum current of 65 A.
Quick Quote
WEG ERC375RW - EXTERNAL RESET CABLE ERC375RW, Overload Relays (Excluding RW17)
Quick Quote
Schneider Electric LR3D3506 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a direct connection type to the contactor for upstream connections, with outgoing cables connected via lugs and a control circuit connected through screw-clamp terminals. This 3-pole relay is engineered for a rated current of 37-50 A, with protection settings adjustable within the same range. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced control flexibility. The LR3D3506 is capable of handling a rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 37 A and a maximum of 50 A.
Quick Quote
Schneider Electric LR3D3406 is a non-differential thermal overload relay designed for unbalanced networks, falling within the LR3D sub-range. It features a direct connection type to the contactor for upstream connections, with outgoing cables connected via lugs and a control circuit connected through screw-clamp terminals. This 3-pole relay is engineered for protection functions classified under Class 10A, with a rated current range of 30-40 A. The protection settings for thermal overload are adjustable between 30-40A. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The rated voltage for phase-to-phase connections is up to 690 V for frequencies ranging from 0 to 400Hz. The minimum operating current is set at 30 A, with a maximum threshold of 40 A.
Quick Quote
Schneider Electric LR3D32L6 is a non-differential thermal overload relay designed for unbalanced networks, falling within the LR3D sub-range. It features a direct connection to the contactor for upstream connections, with outgoing cables connected via lugs and a control circuit utilizing screw-clamp connections. This 3-pole relay is engineered for a rated current of 23-32 A, with protection settings adjustable within the same range. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced functionality. The LR3D32L6 is capable of handling a phase-to-phase rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 23 A and a maximum of 32 A.
Quick Quote
Schneider Electric LR3D318 is a non-differential thermal overload relay designed for unbalanced networks, classified under the LR3D range. It features a direct connection to the contactor for upstream connections and screw-clamp terminals for outgoing cables and the control circuit. This three-pole device offers protection functions with settings adjustable from 12 to 18A, suitable for Class 10A applications. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The LR3D318 is rated for a phase-to-phase voltage of up to 690V (0-400Hz) and supports a minimum current of 12A and a maximum current of 18A.
Quick Quote
Schneider Electric LR3D10L6 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a 3-pole configuration and offers protection functions with a class 20 rating. The relay is designed for direct connection to a contactor upstream, with outgoing cables connected to lugs and a control circuit connected via screw-clamp terminals. It supports a rated current range of 4-6 A, with protection settings adjustable within the same range. The LR3D10L6 includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced control functionality. It is capable of handling a rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 4 A and a maximum of 6 A.
Quick Quote
Schneider Electric LT4760M7S, part of the LT47 sub-range, is a 3-pole electronic overcurrent relay designed for use with 2 measurement current transformers in a control circuit featuring screw-clamp connections. It offers protection functions including electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current range is 5-60 A, with control voltage specifications of 200-240 Vdc for DC and 200-240 Vac (50/60Hz) for AC. Protection settings include thermal overload adjustments from 5-60A, a D-time knob ranging from 0.5-30s, and an O-time knob from 0.3-10s. It also features 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The supply voltage is rated at 200-240 V for both AC and DC, with a rated voltage (AC) phase-to-phase of 690 V (50-60Hz). The minimum and maximum currents are set at 5 A and 60 A, respectively.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LR7K0322 Schneider Electric LR7K0322 is a non-differential thermal overload relay designed for unbalanced networks, classified under the LR7K sub-range. It features a 3-pole configuration and offers protection functions with Class 10A specifications. The relay supports a rated current range of 12-16 A and has protection settings for thermal overload within the same range. Connection types include direct to contactor for upstream connections and screw-clamp for both outgoing cables and the control circuit. It is equipped with 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The rated voltage for phase-to-phase connections is up to 690 V, with a minimum operating current of 12 A and a maximum of 16 A. | Schneider Electric | Quick Quote | |||
LR7K0306 Schneider Electric LR7K0306 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR7K sub-range. It features a 3-pole configuration and offers protection functions classified under Class 10A. The relay is designed for direct connection to a contactor upstream, with outgoing cables connected via screw-clamp and the control circuit also utilizing a screw-clamp connection type. It provides thermal overload protection settings adjustable between 0.8-1.2A. Additionally, it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The LR7K0306 is rated for a phase-to-phase voltage of up to 690 V AC, with a minimum operating current of 0.8 A and a maximum of 1.2 A. | Schneider Electric | Quick Quote | |||
LR3D3656 Schneider Electric LR3D3656 is a non-differential thermal overload relay designed for unbalanced networks, falling within the LR3D sub-range. It features a direct connection type to the contactor for upstream connections, with outgoing cables connected via lugs and a control circuit utilizing screw-clamp connections. This 3-pole relay is engineered for protection functions classified under Class 10A, with a rated current range of 48-65 A. The protection settings for thermal overload are adjustable between 48-65A. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The rated voltage for phase-to-phase connections is up to 690 V for frequencies ranging from 0 to 400Hz. The minimum current specification is 48 A, and it can handle a maximum current of 65 A. | Schneider Electric | Quick Quote | |||
ERC375RW WEG ERC375RW - EXTERNAL RESET CABLE ERC375RW, Overload Relays (Excluding RW17) | WEG | Quick Quote | |||
LR3D3506 Schneider Electric LR3D3506 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a direct connection type to the contactor for upstream connections, with outgoing cables connected via lugs and a control circuit connected through screw-clamp terminals. This 3-pole relay is engineered for a rated current of 37-50 A, with protection settings adjustable within the same range. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced control flexibility. The LR3D3506 is capable of handling a rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 37 A and a maximum of 50 A. | Schneider Electric | Quick Quote | |||
LR3D3406 Schneider Electric LR3D3406 is a non-differential thermal overload relay designed for unbalanced networks, falling within the LR3D sub-range. It features a direct connection type to the contactor for upstream connections, with outgoing cables connected via lugs and a control circuit connected through screw-clamp terminals. This 3-pole relay is engineered for protection functions classified under Class 10A, with a rated current range of 30-40 A. The protection settings for thermal overload are adjustable between 30-40A. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The rated voltage for phase-to-phase connections is up to 690 V for frequencies ranging from 0 to 400Hz. The minimum operating current is set at 30 A, with a maximum threshold of 40 A. | Schneider Electric | Quick Quote | |||
LR3D32L6 Schneider Electric LR3D32L6 is a non-differential thermal overload relay designed for unbalanced networks, falling within the LR3D sub-range. It features a direct connection to the contactor for upstream connections, with outgoing cables connected via lugs and a control circuit utilizing screw-clamp connections. This 3-pole relay is engineered for a rated current of 23-32 A, with protection settings adjustable within the same range. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced functionality. The LR3D32L6 is capable of handling a phase-to-phase rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 23 A and a maximum of 32 A. | Schneider Electric | Quick Quote | |||
LR3D318 Schneider Electric LR3D318 is a non-differential thermal overload relay designed for unbalanced networks, classified under the LR3D range. It features a direct connection to the contactor for upstream connections and screw-clamp terminals for outgoing cables and the control circuit. This three-pole device offers protection functions with settings adjustable from 12 to 18A, suitable for Class 10A applications. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The LR3D318 is rated for a phase-to-phase voltage of up to 690V (0-400Hz) and supports a minimum current of 12A and a maximum current of 18A. | Schneider Electric | Quick Quote | |||
LR3D10L6 Schneider Electric LR3D10L6 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a 3-pole configuration and offers protection functions with a class 20 rating. The relay is designed for direct connection to a contactor upstream, with outgoing cables connected to lugs and a control circuit connected via screw-clamp terminals. It supports a rated current range of 4-6 A, with protection settings adjustable within the same range. The LR3D10L6 includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced control functionality. It is capable of handling a rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 4 A and a maximum of 6 A. | Schneider Electric | Quick Quote | |||
LT4760M7S Schneider Electric LT4760M7S, part of the LT47 sub-range, is a 3-pole electronic overcurrent relay designed for use with 2 measurement current transformers in a control circuit featuring screw-clamp connections. It offers protection functions including electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current range is 5-60 A, with control voltage specifications of 200-240 Vdc for DC and 200-240 Vac (50/60Hz) for AC. Protection settings include thermal overload adjustments from 5-60A, a D-time knob ranging from 0.5-30s, and an O-time knob from 0.3-10s. It also features 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The supply voltage is rated at 200-240 V for both AC and DC, with a rated voltage (AC) phase-to-phase of 690 V (50-60Hz). The minimum and maximum currents are set at 5 A and 60 A, respectively. | Schneider Electric | Quick Quote |