Schneider Electric LRD332L6, part of the LRD sub-range, is a differential thermal overload relay designed for direct connection to a contactor and features screw-clamp terminals for the control circuit. This 3-pole device offers protection functions classified as Class 20, with a rated current range of 23-32 A. It includes protection settings for thermal overload within the same range. The LRD332L6 is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. It supports a rated voltage (AC) for phase-to-phase connections up to 690 V at frequencies from 0 to 400Hz, with a minimum operating current of 23 A and a maximum of 32 A.
Quick Quote
Schneider Electric LRD3326 is a differential thermal overload relay designed for direct connection to a contactor with outgoing cables connected via lugs and control circuits connected through screw-clamp terminals. This 3-pole device offers protection functions classified under Class 10A, with a rated current range of 23-32 A. It features protection settings for thermal overload within the same range. The LRD3326 includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. It is rated for a phase-to-phase voltage of up to 690 V at frequencies ranging from 0 to 400Hz. The minimum operating current is 23 A, and the maximum current capacity is 32 A.
Quick Quote
Schneider Electric LRD318L3 is a differential thermal overload relay within the LRD sub-range, designed for direct connection to a contactor and features spring-type fast connections for both upstream and outgoing cables, as well as the control circuit. This 3-pole device offers protection functions classified as Class 20, with a rated current range of 12-18 A. It includes protection settings for thermal overload within the same range and is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The rated voltage for phase-to-phase operation is up to 690 V at frequencies from 0 to 400Hz, with a minimum operating current of 12 A and a maximum of 18 A.
Quick Quote
Schneider Electric LRD04L, part of the LRD sub-range, is a differential thermal overload relay designed for direct connection to a contactor with outgoing cables connected via screw-clamp and control circuit connections also utilizing screw-clamp technology. This 3-pole device offers protection functions classified as Class 20, with a rated current range of 0.4-0.63 A. It features protection settings for thermal overload from 0.4 to 0.63A, and includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The rated voltage for phase-to-phase operation spans up to 690 V (0-400Hz), with a minimum operating current of 0.4 A and a maximum of 0.63 A.
Quick Quote
Schneider Electric LR3D3253 is a non-differential thermal overload relay designed for unbalanced networks, classified under the LR3D sub-range. It features a 3-pole configuration and offers protection functions with a Class 10A rating. The relay supports a rated current range of 15-25 A, with thermal overload protection settings adjustable within the same range. It is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced connectivity. The connection type for this part includes direct to contactor for upstream connections and spring-type fast connections for both outgoing cables and the control circuit. The LR3D3253 is capable of handling a rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 15 A and a maximum of 25 A.
Quick Quote
Schneider Electric LR3D08L6 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a 3-pole configuration and offers protection functions with a class 20 response. This part is designed for direct connection to a contactor upstream, with outgoing cables connected via lugs and a control circuit connected through screw-clamp terminals. It provides thermal overload protection settings adjustable between 2.5-4A. Additionally, it includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The LR3D08L6 is rated for a phase-to-phase voltage of up to 690 V (0-400Hz) and supports a minimum current of 2.5 A and a maximum current of 4 A.
Quick Quote
Schneider Electric LR3D07L6 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a 3-pole configuration and offers protection with settings adjustable from 1.6 to 2.5A. The connection type includes direct to contactor for upstream connections and lugs for outgoing cables, alongside screw-clamp terminals for the control circuit. This part is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. It is rated for a phase-to-phase voltage of up to 690 V at frequencies ranging from 0 to 400Hz. The rated current spans from a minimum of 1.6 A to a maximum of 2.5 A, classified under protection class 20.
Quick Quote
Schneider Electric LR3D06L is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a direct to contactor connection type for upstream connections and screw-clamp terminals for outgoing cables and the control circuit. This 3-pole relay is equipped with protection functions classified as Class 20. It operates within a rated current range of 1-1.6 A, with protection settings adjustable within the same range. The LR3D06L includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. It is rated for a voltage of up to 690 V AC (0-400Hz) phase-to-phase, with a minimum operating current of 1 A and a maximum of 1.6 A.
Quick Quote
Schneider Electric LR3D05L is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a direct to contactor connection type for upstream connections and screw-clamp terminals for outgoing cables and the control circuit. This 3-pole relay is engineered for protection functions with a Class 20 rating. It operates within a rated current range of 0.63-1 A and offers protection settings for thermal overload from 0.63 to 1A. The LR3D05L includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. It is capable of handling a rated voltage (AC) phase-to-phase of up to 690 V at frequencies from 0 to 400Hz, with a minimum current threshold of 0.63 A and a maximum current capacity of 1 A.
Quick Quote
Schneider Electric LA7D03E, part of the LRD sub-range, is a mounting adapter designed for use with overload relays. This component facilitates the direct mounting of relays onto contactors, ensuring a secure and precise fit for optimal performance in automation systems.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LRD332L6 Schneider Electric LRD332L6, part of the LRD sub-range, is a differential thermal overload relay designed for direct connection to a contactor and features screw-clamp terminals for the control circuit. This 3-pole device offers protection functions classified as Class 20, with a rated current range of 23-32 A. It includes protection settings for thermal overload within the same range. The LRD332L6 is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. It supports a rated voltage (AC) for phase-to-phase connections up to 690 V at frequencies from 0 to 400Hz, with a minimum operating current of 23 A and a maximum of 32 A. | Schneider Electric | Quick Quote | |||
LRD3326 Schneider Electric LRD3326 is a differential thermal overload relay designed for direct connection to a contactor with outgoing cables connected via lugs and control circuits connected through screw-clamp terminals. This 3-pole device offers protection functions classified under Class 10A, with a rated current range of 23-32 A. It features protection settings for thermal overload within the same range. The LRD3326 includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. It is rated for a phase-to-phase voltage of up to 690 V at frequencies ranging from 0 to 400Hz. The minimum operating current is 23 A, and the maximum current capacity is 32 A. | Schneider Electric | Quick Quote | |||
LRD318L3 Schneider Electric LRD318L3 is a differential thermal overload relay within the LRD sub-range, designed for direct connection to a contactor and features spring-type fast connections for both upstream and outgoing cables, as well as the control circuit. This 3-pole device offers protection functions classified as Class 20, with a rated current range of 12-18 A. It includes protection settings for thermal overload within the same range and is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The rated voltage for phase-to-phase operation is up to 690 V at frequencies from 0 to 400Hz, with a minimum operating current of 12 A and a maximum of 18 A. | Schneider Electric | Quick Quote | |||
LRD04L Schneider Electric LRD04L, part of the LRD sub-range, is a differential thermal overload relay designed for direct connection to a contactor with outgoing cables connected via screw-clamp and control circuit connections also utilizing screw-clamp technology. This 3-pole device offers protection functions classified as Class 20, with a rated current range of 0.4-0.63 A. It features protection settings for thermal overload from 0.4 to 0.63A, and includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The rated voltage for phase-to-phase operation spans up to 690 V (0-400Hz), with a minimum operating current of 0.4 A and a maximum of 0.63 A. | Schneider Electric | Quick Quote | |||
LR3D3253 Schneider Electric LR3D3253 is a non-differential thermal overload relay designed for unbalanced networks, classified under the LR3D sub-range. It features a 3-pole configuration and offers protection functions with a Class 10A rating. The relay supports a rated current range of 15-25 A, with thermal overload protection settings adjustable within the same range. It is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced connectivity. The connection type for this part includes direct to contactor for upstream connections and spring-type fast connections for both outgoing cables and the control circuit. The LR3D3253 is capable of handling a rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 15 A and a maximum of 25 A. | Schneider Electric | Quick Quote | |||
LR3D08L6 Schneider Electric LR3D08L6 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a 3-pole configuration and offers protection functions with a class 20 response. This part is designed for direct connection to a contactor upstream, with outgoing cables connected via lugs and a control circuit connected through screw-clamp terminals. It provides thermal overload protection settings adjustable between 2.5-4A. Additionally, it includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The LR3D08L6 is rated for a phase-to-phase voltage of up to 690 V (0-400Hz) and supports a minimum current of 2.5 A and a maximum current of 4 A. | Schneider Electric | Quick Quote | |||
LR3D07L6 Schneider Electric LR3D07L6 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a 3-pole configuration and offers protection with settings adjustable from 1.6 to 2.5A. The connection type includes direct to contactor for upstream connections and lugs for outgoing cables, alongside screw-clamp terminals for the control circuit. This part is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. It is rated for a phase-to-phase voltage of up to 690 V at frequencies ranging from 0 to 400Hz. The rated current spans from a minimum of 1.6 A to a maximum of 2.5 A, classified under protection class 20. | Schneider Electric | Quick Quote | |||
LR3D06L Schneider Electric LR3D06L is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a direct to contactor connection type for upstream connections and screw-clamp terminals for outgoing cables and the control circuit. This 3-pole relay is equipped with protection functions classified as Class 20. It operates within a rated current range of 1-1.6 A, with protection settings adjustable within the same range. The LR3D06L includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. It is rated for a voltage of up to 690 V AC (0-400Hz) phase-to-phase, with a minimum operating current of 1 A and a maximum of 1.6 A. | Schneider Electric | Quick Quote | |||
LR3D05L Schneider Electric LR3D05L is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a direct to contactor connection type for upstream connections and screw-clamp terminals for outgoing cables and the control circuit. This 3-pole relay is engineered for protection functions with a Class 20 rating. It operates within a rated current range of 0.63-1 A and offers protection settings for thermal overload from 0.63 to 1A. The LR3D05L includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. It is capable of handling a rated voltage (AC) phase-to-phase of up to 690 V at frequencies from 0 to 400Hz, with a minimum current threshold of 0.63 A and a maximum current capacity of 1 A. | Schneider Electric | Quick Quote | |||
LA7D03E Schneider Electric LA7D03E, part of the LRD sub-range, is a mounting adapter designed for use with overload relays. This component facilitates the direct mounting of relays onto contactors, ensuring a secure and precise fit for optimal performance in automation systems. | Schneider Electric | Quick Quote |