Schneider Electric LR3D10L6 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a 3-pole configuration and offers protection functions with a class 20 rating. The relay is designed for direct connection to a contactor upstream, with outgoing cables connected to lugs and a control circuit connected via screw-clamp terminals. It supports a rated current range of 4-6 A, with protection settings adjustable within the same range. The LR3D10L6 includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced control functionality. It is capable of handling a rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 4 A and a maximum of 6 A.
Quick Quote
Schneider Electric LT4760M7S, part of the LT47 sub-range, is a 3-pole electronic overcurrent relay designed for use with 2 measurement current transformers in a control circuit featuring screw-clamp connections. It offers protection functions including electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current range is 5-60 A, with control voltage specifications of 200-240 Vdc for DC and 200-240 Vac (50/60Hz) for AC. Protection settings include thermal overload adjustments from 5-60A, a D-time knob ranging from 0.5-30s, and an O-time knob from 0.3-10s. It also features 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The supply voltage is rated at 200-240 V for both AC and DC, with a rated voltage (AC) phase-to-phase of 690 V (50-60Hz). The minimum and maximum currents are set at 5 A and 60 A, respectively.
Quick Quote
Schneider Electric LT4706BS, part of the LT47 sub-range, features a connection type of 2 measurement current transformers with screw-clamp terminals and is designed with 3 poles. It includes protection functions such as an electronic overcurrent relay, locked rotor mechanical jamming, overload protection with Imax greater than Isetting, and sensitivity to phase failure. The rated current for this device ranges from 0.5-6 A, and it operates with a control voltage of 24 Vdc. Protection settings include thermal overload adjustments from 0.5-6A, with a D-time knob ranging from 0.5-30s and an O-time knob from 0.3-10s. It also supports a control voltage (AC) of 24 Vac at 50/60Hz, includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, and requires a supply voltage of 24 V AC/DC. The rated voltage (AC) phase-to-phase is up to 690 V at 50-60Hz, with a minimum current of 0.5 A and a maximum current of 6 A.
Quick Quote
Schneider Electric LR97D015B is a 3-pole electronic overcurrent relay designed for direct connection to a contactor with outgoing cables and control circuits connected via screw-clamp. It features protection functions including electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current range is 0.3-1.5 A, with protection settings for thermal overload adjustable between 0.3-1.5A, a D-time knob setting range of 0.5-30s, and an O-time knob setting range of 0.3-10s. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The supply voltage is 24 V AC/DC, with a rated voltage for phase-to-phase connections at 690 V AC (50-60Hz). The minimum current capability is 0.3 A, and the maximum current capability is 1.5 A.
Quick Quote
Schneider Electric LT4706M7S, part of the LT47 sub-range, is designed with a connection type of 2 measurement current transformers using a screw-clamp and features 3 poles. It includes protection functions such as an electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current for this part ranges from 0.5-6 A, with control voltage specifications of 200-240 Vdc for DC and 200-240 Vac for AC at 50/60Hz. Protection settings are detailed with thermal overload adjustments from 0.5-6A, a D-time knob ranging from 0.5-30s, and an O-time knob from 0.3-10s. It also includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The supply voltage is rated at 200-240 V for both AC and DC, with a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz. The minimum and maximum currents are specified as 0.5 A and 6 A, respectively.
Quick Quote
Schneider Electric LR9F79 is an electronic thermal overload relay designed for protection and control. It belongs to the LR9F sub-range and features a 3-pole configuration. This part is equipped with upstream and outgoing cables lugs, as well as a screw-clamp connection for the control circuit. It offers protection functions classified as Class 10, with a rated current range of 300-500 A. The protection settings for thermal overload are adjustable within the same range. Additionally, it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The LR9F79 operates with a supply voltage of 24 V DC and can handle a rated voltage (AC) of up to 1000 V at 50/60Hz, with a minimum current threshold of 300 A and a maximum of 500 A.
Quick Quote
Schneider Electric LR9F81 is an electronic thermal overload relay designed for advanced protection with a rated current range of 380-630 A. It features a 3-pole configuration and offers connection types including upstream and outgoing cables via lugs and a control circuit through a screw-clamp. This part of the LR9F sub-range provides protection functions classified as Class 10, ensuring precise response to overload conditions. It is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced control flexibility. The LR9F81 operates with a supply voltage of 24 V DC and can handle a rated voltage (AC) of up to 1000 V at 50/60Hz, accommodating a minimum current of 380 A and a maximum current of 630 A.
Quick Quote
Schneider Electric LR97D25B is a 3-pole electronic overcurrent relay designed for direct connection to a contactor with outgoing cables connected via screw-clamp and control circuit connections also utilizing screw-clamp technology. It features protection functions including electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current range is 5-25 A, with protection settings for thermal overload adjustable from 5-25A, a D-time knob ranging from 0.5-30s, and an O-time knob from 0.3-10s. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The supply voltage is 24 V AC/DC, with a rated voltage for phase-to-phase connections at 690 V (50-60Hz). The minimum current capacity is 5 A, and the maximum current capacity is 25 A.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LR3D10L6 Schneider Electric LR3D10L6 is a non-differential thermal overload relay designed for unbalanced networks, belonging to the LR3D sub-range. It features a 3-pole configuration and offers protection functions with a class 20 rating. The relay is designed for direct connection to a contactor upstream, with outgoing cables connected to lugs and a control circuit connected via screw-clamp terminals. It supports a rated current range of 4-6 A, with protection settings adjustable within the same range. The LR3D10L6 includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced control functionality. It is capable of handling a rated voltage (AC) of up to 690 V at frequencies ranging from 0 to 400Hz, with a minimum operating current of 4 A and a maximum of 6 A. | Schneider Electric | Quick Quote | |||
LT4760M7S Schneider Electric LT4760M7S, part of the LT47 sub-range, is a 3-pole electronic overcurrent relay designed for use with 2 measurement current transformers in a control circuit featuring screw-clamp connections. It offers protection functions including electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current range is 5-60 A, with control voltage specifications of 200-240 Vdc for DC and 200-240 Vac (50/60Hz) for AC. Protection settings include thermal overload adjustments from 5-60A, a D-time knob ranging from 0.5-30s, and an O-time knob from 0.3-10s. It also features 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The supply voltage is rated at 200-240 V for both AC and DC, with a rated voltage (AC) phase-to-phase of 690 V (50-60Hz). The minimum and maximum currents are set at 5 A and 60 A, respectively. | Schneider Electric | Quick Quote | |||
LT4706BS Schneider Electric LT4706BS, part of the LT47 sub-range, features a connection type of 2 measurement current transformers with screw-clamp terminals and is designed with 3 poles. It includes protection functions such as an electronic overcurrent relay, locked rotor mechanical jamming, overload protection with Imax greater than Isetting, and sensitivity to phase failure. The rated current for this device ranges from 0.5-6 A, and it operates with a control voltage of 24 Vdc. Protection settings include thermal overload adjustments from 0.5-6A, with a D-time knob ranging from 0.5-30s and an O-time knob from 0.3-10s. It also supports a control voltage (AC) of 24 Vac at 50/60Hz, includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, and requires a supply voltage of 24 V AC/DC. The rated voltage (AC) phase-to-phase is up to 690 V at 50-60Hz, with a minimum current of 0.5 A and a maximum current of 6 A. | Schneider Electric | Quick Quote | |||
LR97D015B Schneider Electric LR97D015B is a 3-pole electronic overcurrent relay designed for direct connection to a contactor with outgoing cables and control circuits connected via screw-clamp. It features protection functions including electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current range is 0.3-1.5 A, with protection settings for thermal overload adjustable between 0.3-1.5A, a D-time knob setting range of 0.5-30s, and an O-time knob setting range of 0.3-10s. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts. The supply voltage is 24 V AC/DC, with a rated voltage for phase-to-phase connections at 690 V AC (50-60Hz). The minimum current capability is 0.3 A, and the maximum current capability is 1.5 A. | Schneider Electric | Quick Quote | |||
BF112 WEG BF112 - MOUNTING BASE BF112, Overload Relays (Excluding RW17) | WEG | Quick Quote | |||
BF27-2D WEG BF27-2D - MOUNTING BASE BF27-2D, Overload Relays (Excluding RW17) | WEG | Quick Quote | |||
LT4706M7S Schneider Electric LT4706M7S, part of the LT47 sub-range, is designed with a connection type of 2 measurement current transformers using a screw-clamp and features 3 poles. It includes protection functions such as an electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current for this part ranges from 0.5-6 A, with control voltage specifications of 200-240 Vdc for DC and 200-240 Vac for AC at 50/60Hz. Protection settings are detailed with thermal overload adjustments from 0.5-6A, a D-time knob ranging from 0.5-30s, and an O-time knob from 0.3-10s. It also includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The supply voltage is rated at 200-240 V for both AC and DC, with a rated voltage (AC) phase-to-phase of 690 V at 50-60Hz. The minimum and maximum currents are specified as 0.5 A and 6 A, respectively. | Schneider Electric | Quick Quote | |||
LR9F79 Schneider Electric LR9F79 is an electronic thermal overload relay designed for protection and control. It belongs to the LR9F sub-range and features a 3-pole configuration. This part is equipped with upstream and outgoing cables lugs, as well as a screw-clamp connection for the control circuit. It offers protection functions classified as Class 10, with a rated current range of 300-500 A. The protection settings for thermal overload are adjustable within the same range. Additionally, it includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The LR9F79 operates with a supply voltage of 24 V DC and can handle a rated voltage (AC) of up to 1000 V at 50/60Hz, with a minimum current threshold of 300 A and a maximum of 500 A. | Schneider Electric | Quick Quote | |||
LR9F81 Schneider Electric LR9F81 is an electronic thermal overload relay designed for advanced protection with a rated current range of 380-630 A. It features a 3-pole configuration and offers connection types including upstream and outgoing cables via lugs and a control circuit through a screw-clamp. This part of the LR9F sub-range provides protection functions classified as Class 10, ensuring precise response to overload conditions. It is equipped with 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts for enhanced control flexibility. The LR9F81 operates with a supply voltage of 24 V DC and can handle a rated voltage (AC) of up to 1000 V at 50/60Hz, accommodating a minimum current of 380 A and a maximum current of 630 A. | Schneider Electric | Quick Quote | |||
LR97D25B Schneider Electric LR97D25B is a 3-pole electronic overcurrent relay designed for direct connection to a contactor with outgoing cables connected via screw-clamp and control circuit connections also utilizing screw-clamp technology. It features protection functions including electronic overcurrent relay, locked rotor mechanical jamming, overload with Imax greater than Isetting, and sensitivity to phase failure. The rated current range is 5-25 A, with protection settings for thermal overload adjustable from 5-25A, a D-time knob ranging from 0.5-30s, and an O-time knob from 0.3-10s. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact. The supply voltage is 24 V AC/DC, with a rated voltage for phase-to-phase connections at 690 V (50-60Hz). The minimum current capacity is 5 A, and the maximum current capacity is 25 A. | Schneider Electric | Quick Quote |