SLCASKCVR SolaHD - SolaHD™ SL Series Single and Multi Output Power Supplies - PN SLCASKCVR
Quick Quote
SLD12101012T SolaHD - SolaHD™ SL Series Single and Multi Output Power Supplies - PN SLD12101012T
Quick Quote
PULS CP5.241-S1 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing and dimensions of W32mm x H124mm x D102mm. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 32 mm. The unit offers a current consumption of 7A peak max. inrush at both 230Vac and 120Vac input, with efficiencies of 0.943, 0.935, and 0.927 at 230Vac, 120Vac, and 100Vac inputs respectively. It includes a time delay of 380-420ms for start-up and rise times of 80ms and 100ms under specified conditions. The CP5.241-S1 provides protection functions such as output overvoltage and overload/short-circuit current protection, with the capability for series or parallel operation for increased output voltages or power. It is resistant to back-feeding loads up to 35V. Power dissipation/losses are 7.3 W and 8.2 W for 230Vac and 120Vac inputs at full output load, respectively. The unit's output stage capacitance is 1800 µF, and it demonstrates electrical durability across various conditions, with the longest lifespan reaching up to 775000 hours. The ripple is specified at 50mVpp (20Hz...20MHz; 50Ω). This AC/DC power supply unit, part of the CP-series, is designed with a 20% power reserve and includes a DC-OK relay contact output. It features spring-clamp connections and supports a supply voltage range of 85Vac-264Vac for AC and 110Vdc-180Vdc for DC, with a rated current of 5A at 24Vdc. The output voltage is adjustable between 24Vdc and 28Vdc, and the unit offers a hold time of 35ms. It is suitable for single-phase (1AC) or DC networks and provides a rated power of 120W.
Quick Quote
PULS PISA11.401 is a protection unit designed as a 4-channel protection module with 1 input and 4 outputs, suitable for DIN rail mounting. It operates within an ambient air temperature range of -25 to +70°C and adheres to NEC Class 2 design specifications. The rated current is 20A, distributed as 6A + 6A + 12A + 12A with a derating of 0.025A/+60°C to +70°C for each channel. It features screw-clamp connections for secure installation. As part of the PISA11-series, this unit has dimensions of W45mm x H75mm x D91mm and requires a supply voltage of 18Vdc to 30Vdc, with 24Vdc being typical and 21.4Vdc needed to turn on the outputs. The output voltage is adjustable between 24Vdc and 28Vdc. Protection functions include short-circuit protection with an 8ms shutdown time and current limitation with a 20.5A to 30A adjustable threshold. Power dissipation at full output load with a 24V input is 4.2W. The processing time for turn-on delay of output is 270ms, and the voltage drop across channels 1+2 and 3+4 is 178mV and 182mV, respectively. Electrical durability is rated at 171,000 hours at 40°C and 485,000 hours at 25°C for outputs of 2x3A and 2x5A.
Quick Quote
PULS PISA11.410 is a protection unit designed as a 4-channel protection module with 1 input and 4 outputs, suitable for DIN rail mounting. It operates within an ambient air temperature range of -25 to +70°C and is designed according to NEC Class 2 standards. The rated current is 14.8A at 24Vdc, with screw-clamp connections for secure installation. As part of the PISA11-series, it measures 45mm in width, 75mm in height, and 91mm in depth. The supply voltage requirement ranges from 18Vdc to 30Vdc, with a specific input voltage of 21.4Vdc needed to activate the outputs. The output voltage is adjustable between 24Vdc and 28Vdc. Protection functions include short-circuit protection with a 10ms shutdown time and current limitation with an adjustable threshold between 16.6A and 23.6A. Power dissipation at full output load with a 24V input is 1.6W. The processing time for turn-on delay of output is 270ms, and the voltage drop is 92mV at 24V and 81mV at 28V. Electrical durability is rated at 220,000 hours at 40°C with 4x1.9A output and 622,000 hours at 25°C with 4x1.9A output.
Quick Quote
PULS QS40.484 is a power supply unit designed for DIN rail mounting, featuring AC/DC conversion with a 50% power reserve. It operates within an ambient air temperature range of -25 to +70°C and offers a design that includes a DC-OK relay contact output. The unit provides a rated current of 20A at 48Vdc and 17.8A at 54Vdc, with a power derating applicable from 24W at +60°C to +70°C. Connection is facilitated through screw-clamp connections, and it supports a supply voltage range of 180Vac to 264Vac, accommodating various nominal voltages within this range at a frequency of 47-63Hz. The QS40.484, part of the Q-series, measures 125mm in width, 124mm in height, and 127mm in depth, housed in an aluminium casing. It is designed for single-phase network operation and delivers a rated power of 960W, with a short-term capacity of 1440W for up to 4 seconds. The output voltage is adjustable between 48Vdc and 54Vdc. Protection features include output overvoltage protection and overload/short-circuit protection, with capabilities for series or parallel operation to increase output power. Efficiency is rated at 0.95 with a 230Vac input, and the unit exhibits a peak current consumption of 18A. Start-up and rise times are specified as 750ms and 18-35ms respectively, with a hold time of 30ms at 230Vac input. Power dissipation losses are detailed for both 230Vac and 120Vac inputs, and the electrical durability spans from 65,000 to 345,000 hours under various conditions. Ripple is maintained at 150mVpp across a 20Hz to 20MHz range, with an output stage capacitance of 3700µF.
Quick Quote
PULS SLD2.100 is a power supply unit featuring galvanic isolation and a DC-OK relay contact output. It serves as both an AC/DC power supply unit (PSU) and a DC/DC converter, equipped with screw-clamp connections for secure installation. The dimensions of this unit are W49mm x H124mm x D102mm, designed for DIN rail mounting, making it suitable for compact spaces. It operates with a supply voltage range of 18Vdc-36Vdc (24Vdc nominal) and delivers a rated current of 8A at 4.5Vdc with a power derating from +60°C to +70°C. The ambient air temperature for operation spans from 0 to +70 °C. The SLD2.100 consumes 2.9A at full 18Vdc output and 1.5A at full 36Vdc output, supporting both series and parallel operation. The output voltage is adjustable between 4.5-5.5Vdc, with an efficiency of 0.82 at 24Vdc input. This unit offers a rated power of 40W, a hold time of 10ms at 24Vdc input, and experiences power dissipation/losses of 8.5W at 24Vdc input with a full output load. Additionally, it features a 300ms start-up delay and maintains a ripple of 50mVpp across a frequency range of 20Hz to 20MHz at 50Ω.
Quick Quote
PULS CPS20.241-C1 is a DIN rail mounting power supply unit with an aluminium housing designed for a wide range of industrial applications. It operates within an ambient air temperature range of -25 to +70°C and offers a net width of 65mm. This unit consumes current at rates of 2.33A with a 230Vac input, 4.36A with a 120Vac input, and 5.25A with a 100Vac input for full 24Vdc output, and features a peak max. inrush current of 13A at both 230Vac and 120Vac inputs. It boasts an efficiency of 0.94 at 230Vac input, 0.927 at 120Vac input, and 0.92 at 100Vac input. The CPS20.241-C1 is IP20 rated, indicating protection against solid objects larger than 12mm but not against water. It is chemically resistant with a conformal coated PCB, suitable for harsh environments. The dimensions are W65mm x H124mm x D127mm. It has a start-up delay of 850ms and rise times of 85ms and 150ms under specified conditions. The unit provides output overvoltage protection, overload/short-circuit protection, and supports series/parallel operation for increased output power. It can handle back-feeding loads up to 35V without malfunctioning. Power dissipation/losses are 30.6W, and the output stage capacitance is 7000µF. Electrical durability varies with conditions, reaching up to 475000 hours. Ripple is maintained at 50mVpp. This AC/DC converter features a 20% power reserve, is part of the C-series, and includes ATEX approval conformal coating, DC-OK relay contact output, and screw-clamp connections. It accepts a supply voltage range of 85Vac-264Vac, with specific shutdown voltages under varying loads, and provides a rated current of 20A at 24Vdc. Designed for single-phase networks, it offers a rated power of 576W under PowerBoost at ambient temperatures less than 45°C and 480W at less than 60°C. The output voltage is adjustable between 24Vdc and 28Vdc, with a 200mV turn-ON overshoot and a hold time of 26ms.
Quick Quote
PULS UF40.241 is an Uninterruptible Power Supply (UPS) control module within the UF-series, designed as a bfr. module with capacitor storage and a green status LED. It features a DC/DC UPS control mechanism with a 34-second charging time, encased in an aluminium housing. The unit offers screw-clamp connections for secure installation and measures W64mm x H124mm x D142mm. It operates on a supply voltage range of 19.2Vdc to 30Vdc, with a nominal 24Vdc, and supports a rated current of 40A (bfr.). Designed for DIN rail mounting, the UF40.241 can function within an ambient air temperature range of -25 to +70°C and is suitable for DC networks. It includes a visual position indicator for Ready, Buffering, and Inhibit statuses. The module provides protection against output overvoltage, with typical protection at 32Vdc and a maximum of 35Vdc. It allows for parallel connection of buffer modules to enhance output ampacity or hold-up time. The output voltage is fixed at 24Vdc, with an efficiency of 0.99 at a 24Vdc input. The hold time is specified as 25ms/0.25s at 40A load and 50ms/0.5s at 20A load. Power dissipation/losses are noted as 1.9 W at a 24Vdc input with 0A output current, and the ripple is 200mVpp across a frequency range of 20Hz to 20MHz at 50Ω. Electrical durability is rated at 189,000 hours at 40°C and 536,000 hours at 25°C in standby mode.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
SLCASKCVR SLCASKCVR SolaHD - SolaHD™ SL Series Single and Multi Output Power Supplies - PN SLCASKCVR | SolaHD | Quick Quote | |||
SVL124100 SVL124100 SolaHD - SolaHD™ SVL Series Power Supplies - PN SVL124100 | SolaHD | Quick Quote | |||
SLD12101012T SLD12101012T SolaHD - SolaHD™ SL Series Single and Multi Output Power Supplies - PN SLD12101012T | SolaHD | Quick Quote | |||
CP5.241-S1 PULS CP5.241-S1 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing and dimensions of W32mm x H124mm x D102mm. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 32 mm. The unit offers a current consumption of 7A peak max. inrush at both 230Vac and 120Vac input, with efficiencies of 0.943, 0.935, and 0.927 at 230Vac, 120Vac, and 100Vac inputs respectively. It includes a time delay of 380-420ms for start-up and rise times of 80ms and 100ms under specified conditions. The CP5.241-S1 provides protection functions such as output overvoltage and overload/short-circuit current protection, with the capability for series or parallel operation for increased output voltages or power. It is resistant to back-feeding loads up to 35V. Power dissipation/losses are 7.3 W and 8.2 W for 230Vac and 120Vac inputs at full output load, respectively. The unit's output stage capacitance is 1800 µF, and it demonstrates electrical durability across various conditions, with the longest lifespan reaching up to 775000 hours. The ripple is specified at 50mVpp (20Hz...20MHz; 50Ω). This AC/DC power supply unit, part of the CP-series, is designed with a 20% power reserve and includes a DC-OK relay contact output. It features spring-clamp connections and supports a supply voltage range of 85Vac-264Vac for AC and 110Vdc-180Vdc for DC, with a rated current of 5A at 24Vdc. The output voltage is adjustable between 24Vdc and 28Vdc, and the unit offers a hold time of 35ms. It is suitable for single-phase (1AC) or DC networks and provides a rated power of 120W. | Puls | Quick Quote | |||
PISA11.401 PULS PISA11.401 is a protection unit designed as a 4-channel protection module with 1 input and 4 outputs, suitable for DIN rail mounting. It operates within an ambient air temperature range of -25 to +70°C and adheres to NEC Class 2 design specifications. The rated current is 20A, distributed as 6A + 6A + 12A + 12A with a derating of 0.025A/+60°C to +70°C for each channel. It features screw-clamp connections for secure installation. As part of the PISA11-series, this unit has dimensions of W45mm x H75mm x D91mm and requires a supply voltage of 18Vdc to 30Vdc, with 24Vdc being typical and 21.4Vdc needed to turn on the outputs. The output voltage is adjustable between 24Vdc and 28Vdc. Protection functions include short-circuit protection with an 8ms shutdown time and current limitation with a 20.5A to 30A adjustable threshold. Power dissipation at full output load with a 24V input is 4.2W. The processing time for turn-on delay of output is 270ms, and the voltage drop across channels 1+2 and 3+4 is 178mV and 182mV, respectively. Electrical durability is rated at 171,000 hours at 40°C and 485,000 hours at 25°C for outputs of 2x3A and 2x5A. | Puls | Quick Quote | |||
PISA11.410 PULS PISA11.410 is a protection unit designed as a 4-channel protection module with 1 input and 4 outputs, suitable for DIN rail mounting. It operates within an ambient air temperature range of -25 to +70°C and is designed according to NEC Class 2 standards. The rated current is 14.8A at 24Vdc, with screw-clamp connections for secure installation. As part of the PISA11-series, it measures 45mm in width, 75mm in height, and 91mm in depth. The supply voltage requirement ranges from 18Vdc to 30Vdc, with a specific input voltage of 21.4Vdc needed to activate the outputs. The output voltage is adjustable between 24Vdc and 28Vdc. Protection functions include short-circuit protection with a 10ms shutdown time and current limitation with an adjustable threshold between 16.6A and 23.6A. Power dissipation at full output load with a 24V input is 1.6W. The processing time for turn-on delay of output is 270ms, and the voltage drop is 92mV at 24V and 81mV at 28V. Electrical durability is rated at 220,000 hours at 40°C with 4x1.9A output and 622,000 hours at 25°C with 4x1.9A output. | Puls | Quick Quote | |||
QS40.484 PULS QS40.484 is a power supply unit designed for DIN rail mounting, featuring AC/DC conversion with a 50% power reserve. It operates within an ambient air temperature range of -25 to +70°C and offers a design that includes a DC-OK relay contact output. The unit provides a rated current of 20A at 48Vdc and 17.8A at 54Vdc, with a power derating applicable from 24W at +60°C to +70°C. Connection is facilitated through screw-clamp connections, and it supports a supply voltage range of 180Vac to 264Vac, accommodating various nominal voltages within this range at a frequency of 47-63Hz. The QS40.484, part of the Q-series, measures 125mm in width, 124mm in height, and 127mm in depth, housed in an aluminium casing. It is designed for single-phase network operation and delivers a rated power of 960W, with a short-term capacity of 1440W for up to 4 seconds. The output voltage is adjustable between 48Vdc and 54Vdc. Protection features include output overvoltage protection and overload/short-circuit protection, with capabilities for series or parallel operation to increase output power. Efficiency is rated at 0.95 with a 230Vac input, and the unit exhibits a peak current consumption of 18A. Start-up and rise times are specified as 750ms and 18-35ms respectively, with a hold time of 30ms at 230Vac input. Power dissipation losses are detailed for both 230Vac and 120Vac inputs, and the electrical durability spans from 65,000 to 345,000 hours under various conditions. Ripple is maintained at 150mVpp across a 20Hz to 20MHz range, with an output stage capacitance of 3700µF. | Puls | Quick Quote | |||
SLD2.100 PULS SLD2.100 is a power supply unit featuring galvanic isolation and a DC-OK relay contact output. It serves as both an AC/DC power supply unit (PSU) and a DC/DC converter, equipped with screw-clamp connections for secure installation. The dimensions of this unit are W49mm x H124mm x D102mm, designed for DIN rail mounting, making it suitable for compact spaces. It operates with a supply voltage range of 18Vdc-36Vdc (24Vdc nominal) and delivers a rated current of 8A at 4.5Vdc with a power derating from +60°C to +70°C. The ambient air temperature for operation spans from 0 to +70 °C. The SLD2.100 consumes 2.9A at full 18Vdc output and 1.5A at full 36Vdc output, supporting both series and parallel operation. The output voltage is adjustable between 4.5-5.5Vdc, with an efficiency of 0.82 at 24Vdc input. This unit offers a rated power of 40W, a hold time of 10ms at 24Vdc input, and experiences power dissipation/losses of 8.5W at 24Vdc input with a full output load. Additionally, it features a 300ms start-up delay and maintains a ripple of 50mVpp across a frequency range of 20Hz to 20MHz at 50Ω. | Puls | Quick Quote | |||
CPS20.241-C1 PULS CPS20.241-C1 is a DIN rail mounting power supply unit with an aluminium housing designed for a wide range of industrial applications. It operates within an ambient air temperature range of -25 to +70°C and offers a net width of 65mm. This unit consumes current at rates of 2.33A with a 230Vac input, 4.36A with a 120Vac input, and 5.25A with a 100Vac input for full 24Vdc output, and features a peak max. inrush current of 13A at both 230Vac and 120Vac inputs. It boasts an efficiency of 0.94 at 230Vac input, 0.927 at 120Vac input, and 0.92 at 100Vac input. The CPS20.241-C1 is IP20 rated, indicating protection against solid objects larger than 12mm but not against water. It is chemically resistant with a conformal coated PCB, suitable for harsh environments. The dimensions are W65mm x H124mm x D127mm. It has a start-up delay of 850ms and rise times of 85ms and 150ms under specified conditions. The unit provides output overvoltage protection, overload/short-circuit protection, and supports series/parallel operation for increased output power. It can handle back-feeding loads up to 35V without malfunctioning. Power dissipation/losses are 30.6W, and the output stage capacitance is 7000µF. Electrical durability varies with conditions, reaching up to 475000 hours. Ripple is maintained at 50mVpp. This AC/DC converter features a 20% power reserve, is part of the C-series, and includes ATEX approval conformal coating, DC-OK relay contact output, and screw-clamp connections. It accepts a supply voltage range of 85Vac-264Vac, with specific shutdown voltages under varying loads, and provides a rated current of 20A at 24Vdc. Designed for single-phase networks, it offers a rated power of 576W under PowerBoost at ambient temperatures less than 45°C and 480W at less than 60°C. The output voltage is adjustable between 24Vdc and 28Vdc, with a 200mV turn-ON overshoot and a hold time of 26ms. | Puls | Quick Quote | |||
UF40.241 PULS UF40.241 is an Uninterruptible Power Supply (UPS) control module within the UF-series, designed as a bfr. module with capacitor storage and a green status LED. It features a DC/DC UPS control mechanism with a 34-second charging time, encased in an aluminium housing. The unit offers screw-clamp connections for secure installation and measures W64mm x H124mm x D142mm. It operates on a supply voltage range of 19.2Vdc to 30Vdc, with a nominal 24Vdc, and supports a rated current of 40A (bfr.). Designed for DIN rail mounting, the UF40.241 can function within an ambient air temperature range of -25 to +70°C and is suitable for DC networks. It includes a visual position indicator for Ready, Buffering, and Inhibit statuses. The module provides protection against output overvoltage, with typical protection at 32Vdc and a maximum of 35Vdc. It allows for parallel connection of buffer modules to enhance output ampacity or hold-up time. The output voltage is fixed at 24Vdc, with an efficiency of 0.99 at a 24Vdc input. The hold time is specified as 25ms/0.25s at 40A load and 50ms/0.5s at 20A load. Power dissipation/losses are noted as 1.9 W at a 24Vdc input with 0A output current, and the ripple is 200mVpp across a frequency range of 20Hz to 20MHz at 50Ω. Electrical durability is rated at 189,000 hours at 40°C and 536,000 hours at 25°C in standby mode. | Puls | Quick Quote |