Inductive Sensor, Rated switching distance 1.5 mm, Flush, M8 × 1 threaded barrel, Stainless steel, 1.4305 (AISI 303), DC 3-wire, 10…30 VDC, NO contact, NPN output, M8 x 1 male connector
Quick Quote
Inductive Sensor, Rated switching distance 8 mm, Cable length (L) 1 m, Non-flush, M12 × 1 threaded barrel, Chrome-plated brass, Factor 1 for all metals, Protection class IP68, Resistant to magnetic fields, Extended temperature range, High switching frequency, DC 3-wire, 10…30 VDC, NO contact, PNP output, Pigtail with male end M12 x 1
Quick Quote
Inductive Sensor, Rated switching distance 1.5 mm, Cable length (L) 2 m, Flush, M8 × 1 threaded tube, Stainless steel, 1.4305 (AISI 303), DC 3-wire, 10…30 VDC, NC contact, PNP output, Cable connection
Quick Quote
Inductive Sensor, Monitoring Kit for Power Clamps, Rated switching distance 2 mm, Cable length (L) 0.1 m, Non-flush, Rectangular, height 23.5 mm, Plastic, PP GR-20, Resistant to magnetic fields (weld-resistant), for DC and AC fields up to 100 mT, AC 4-wire, 20…250 VDC, DC 4-wire, 10…300 VDC, 2 x NO contact, 1/2 male connector, "
Quick Quote
Inductive Sensor, Rated switching distance 8 mm, Non-flush, Threaded barrel, M12 × 1, Brass, PTFE-coated, Factor 1 for all metals, Protection class IP68, Resistant to magnetic fields, Extended temperature range, High switching frequency, AC 2-wire, 20…250 VAC, DC 2-wire, 10…300 VDC, NO contact, 1/2 male connector, "
Quick Quote
Inductive Sensor, Rated switching distance 5 mm, Flush, Threaded barrel, M18 x 1, Plastic, PA12‐GF30-V0, AC 2-wire, 20…250 VAC, DC 2-wire, 10…300 VDC, NO contact, 7/8 connector, "
Quick Quote
Inductive Sensor, Rated switching distance 1 mm, Cable length (L) 0.2 m, Flush, Threaded barrel, M5 x 0.5, Stainless steel, 1.4427 SO, DC 3-wire, 10…30 VDC, NO contact, PNP output, Pigtail with male end M8 x 1
Quick Quote
Inductive Sensor, Rated switching distance 1 mm, Cable length (L) 0.2 m, Flush, Smooth barrel, Ø 4 mm, Stainless steel, 1.4427, DC 2-wire, nom. 8.2 VDC, Output acc. to DIN EN 60947-5-6 (NAMUR), Pigtail with male end M8 x 1, ATEX category II 2 G, Ex zone 1, ATEX category II 1 D, Ex zone 20, SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0, SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1 with redundant configuration HFT1
Quick Quote
Inductive Sensor, With Analog Output, Measuring range 1 mm, Max. measuring range 2.5 mm, Flush, M12 × 1 threaded barrel, Chrome-plated brass, 4‐wire, 15…30 VDC, Analog output, 0…10 V and 0…20 mA, M12 x 1 male connector
Quick Quote
Inductive Sensor, With Extended Switching Distance, Rated switching distance 35 mm, Non-flush, Rectangular, height 40 mm, Variable orientation of active face in 5 directions, Plastic, PBT‐GF30‐V0, Factor 1 for all metals, Increased switching distance, Protection class IP68, Large coverage, Resistant to magnetic fields, Extended temperature range, High switching frequency, AC 2-wire, 20…250 VAC, DC 2-wire, 10…300 VDC, NC contact, 1/2" male connector
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
BI1.5-EG08K-AN6X-V1131 Inductive Sensor, Rated switching distance 1.5 mm, Flush, M8 × 1 threaded barrel, Stainless steel, 1.4305 (AISI 303), DC 3-wire, 10…30 VDC, NO contact, NPN output, M8 x 1 male connector | Turck | $116.10 | Quick Quote | ||
NI8U-M12-AP6X-1-RS4T Inductive Sensor, Rated switching distance 8 mm, Cable length (L) 1 m, Non-flush, M12 × 1 threaded barrel, Chrome-plated brass, Factor 1 for all metals, Protection class IP68, Resistant to magnetic fields, Extended temperature range, High switching frequency, DC 3-wire, 10…30 VDC, NO contact, PNP output, Pigtail with male end M12 x 1 | Turck | $134.20 | Quick Quote | ||
BI1.5-EG08K-RP6X Inductive Sensor, Rated switching distance 1.5 mm, Cable length (L) 2 m, Flush, M8 × 1 threaded tube, Stainless steel, 1.4305 (AISI 303), DC 3-wire, 10…30 VDC, NC contact, PNP output, Cable connection | Turck | $116.10 | Quick Quote | ||
NI2-Q9.5-ADZ32-0.1-FSB5.4X4/S304 Inductive Sensor, Monitoring Kit for Power Clamps, Rated switching distance 2 mm, Cable length (L) 0.1 m, Non-flush, Rectangular, height 23.5 mm, Plastic, PP GR-20, Resistant to magnetic fields (weld-resistant), for DC and AC fields up to 100 mT, AC 4-wire, 20…250 VDC, DC 4-wire, 10…300 VDC, 2 x NO contact, 1/2 male connector, " | Turck | $267.10 | Quick Quote | ||
NI8U-GT12-ADZ32X-B3131 Inductive Sensor, Rated switching distance 8 mm, Non-flush, Threaded barrel, M12 × 1, Brass, PTFE-coated, Factor 1 for all metals, Protection class IP68, Resistant to magnetic fields, Extended temperature range, High switching frequency, AC 2-wire, 20…250 VAC, DC 2-wire, 10…300 VDC, NO contact, 1/2 male connector, " | Turck | $224.40 | Quick Quote | ||
BI5-P18-AZ3X-B2331 Inductive Sensor, Rated switching distance 5 mm, Flush, Threaded barrel, M18 x 1, Plastic, PA12‐GF30-V0, AC 2-wire, 20…250 VAC, DC 2-wire, 10…300 VDC, NO contact, 7/8 connector, " | Turck | $142.60 | Quick Quote | ||
BI1-EG05-AP6X-0.2-PSG3F Inductive Sensor, Rated switching distance 1 mm, Cable length (L) 0.2 m, Flush, Threaded barrel, M5 x 0.5, Stainless steel, 1.4427 SO, DC 3-wire, 10…30 VDC, NO contact, PNP output, Pigtail with male end M8 x 1 | Turck | $163.30 | Quick Quote | ||
BI1-EH04-Y1-0.2-PSG3M Inductive Sensor, Rated switching distance 1 mm, Cable length (L) 0.2 m, Flush, Smooth barrel, Ø 4 mm, Stainless steel, 1.4427, DC 2-wire, nom. 8.2 VDC, Output acc. to DIN EN 60947-5-6 (NAMUR), Pigtail with male end M8 x 1, ATEX category II 2 G, Ex zone 1, ATEX category II 1 D, Ex zone 20, SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0, SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1 with redundant configuration HFT1 | Turck | $105.20 | Quick Quote | ||
BI2-M12-LIU-H1141 Inductive Sensor, With Analog Output, Measuring range 1 mm, Max. measuring range 2.5 mm, Flush, M12 × 1 threaded barrel, Chrome-plated brass, 4‐wire, 15…30 VDC, Analog output, 0…10 V and 0…20 mA, M12 x 1 male connector | Turck | $309.20 | Quick Quote | ||
NI35U-CK40-RDZ30X2-B3131 Inductive Sensor, With Extended Switching Distance, Rated switching distance 35 mm, Non-flush, Rectangular, height 40 mm, Variable orientation of active face in 5 directions, Plastic, PBT‐GF30‐V0, Factor 1 for all metals, Increased switching distance, Protection class IP68, Large coverage, Resistant to magnetic fields, Extended temperature range, High switching frequency, AC 2-wire, 20…250 VAC, DC 2-wire, 10…300 VDC, NC contact, 1/2" male connector | Turck | $215.30 | Quick Quote |