| SCP30S15BDN SCP30S15BDN SolaHD - SolaHD™ SCP Series 30 Watt Switched Power Supplies - PN SCP30S15BDN | SolaHD | | |
| SVL1024480 SVL1024480 SolaHD - SolaHD™ SVL Series Power Supplies - PN SVL1024480 | SolaHD | | |
| SVL424100 SVL424100 SolaHD - SolaHD™ SVL Series Power Supplies - PN SVL424100 | SolaHD | | |
| SLS050301T SLS050301T SolaHD - SolaHD™ SL Series Single and Multi Output Power Supplies - PN SLS050301T | SolaHD | | |
| SVL5-24-100 SVL5-24-100 SolaHD single phase power supply, 100-240 VAC input, 24 VDC output, 5 A, 120W | SolaHD | | |
| 787-822 787-822 WAGO - EPSITRON® PRO Power supply; single-phase; output voltage 24 VDC; 5 A; PowerBoost | WAGO | | |
| ML50.111 PULS ML50.111 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and features a plug connector NEC Class 2 optimized for parallel use, including a DC-OK relay contact output. The unit has a rated current of 2.1A at 24Vdc and utilizes screw-clamp connections for secure installation. It supports a wide supply voltage range from 85Vac to 264Vac (with specific nominal values across 100Vac to 240Vac; 47-63Hz), including a 65Vac turn-ON voltage and a 55Vac shutdown voltage, as well as a DC supply voltage range from 88Vdc to 375Vdc. The ML50.111 is housed in a PC / ABS blend, measuring 45mm in width, 75mm in height, and 91mm in depth. It is compatible with single-phase (1AC) or DC networks, has a rated power of 50W, and provides an adjustable output voltage from 24Vdc to 28Vdc with a 400mV turn-ON overshoot. Protection is ensured by an NTC (input inrush current limiter), and the unit boasts an efficiency of 0.885 at 230Vac input. Maximum current consumption is 17A at 120Vac input and 35A peak at 230Vac input, with power dissipation/losses at 6.8W and a ripple of 50mVpp across 20Hz to 20MHz at 50Ω. The output stage capacitance is 1600µF. | Puls | | |
| QS10.481-D1 PULS QS10.481-D1 is a power supply unit designed for DIN rail mounting, featuring AC/DC conversion with a 50% power reserve. It operates within an ambient air temperature range of -25 to +70°C and includes an extended DC input for enhanced versatility. The unit provides a rated current of 5A at 48Vdc and 4.3A at 56Vdc, with a derating of 6W from +60°C to +70°C. Connection is facilitated through spring-clamp connections. It supports a supply voltage range of 85Vac-264Vac for AC and 88Vdc-188Vdc for DC, with specific nominal values across a broad spectrum. The QS10.481-D1, part of the Q-series, measures 60mm in width, 124mm in height, and 117mm in depth, and is housed in aluminium for durability. It is compatible with single-phase AC or DC networks and offers a rated power of 240W, with a short-term capacity of 360W for up to 4 seconds. The output voltage is adjustable between 48Vdc and 56Vdc. Protection features include output overvoltage protection and overload/short-circuit protection, with capabilities for series or parallel operation for increased output power. Efficiency rates vary by input voltage, achieving up to 0.92 at 230Vac. The unit exhibits a peak inrush current consumption of 10A, with a start-up delay between 340-800ms and a hold time of 28ms at 230Vac input. Power dissipation is noted at 20.9W for 230Vac input under full load. Electrical durability spans up to 228000 hours under specific conditions, with a ripple of 100mVpp and an output stage capacitance of 3000µF. | Puls | | |
| QT40.361 PULS QT40.361 is a power supply unit designed for AC/DC conversion with a 50% power reserve. It features DIN rail mounting and operates within an ambient air temperature range of -25 to +70°C. The unit is equipped with a DC-OK relay contact output and offers a rated current of 26.7A at 36Vdc and 22.9A at 42Vdc, with a power derating of 24W at temperatures from +60°C to +70°C. Connection is facilitated through screw-clamp connections. The supply voltage accommodates a wide range of 323Vac to 576Vac (with nominal values including 380Vac, 400Vac, 415Vac, 440Vac, 480Vac, 500Vac, and 525Vac; 47-63Hz), featuring a 3-phase input, a turn-ON voltage of 3 x 305Vac, and a shutdown voltage of 3 x 275Vac in steady-state conditions. This part of the Q-series measures W110mm x H124mm x D127mm and is housed in aluminium. It is designed for a 3-phase network, with a net width of 110 mm. The rated power is 960W at both 36Vdc and 42Vdc, with a short-term capacity of 1440W for up to 4 seconds. The output voltage is adjustable between 36Vdc and 42Vdc, with a turn-ON overshoot of 750mV. Protection functions include output overvoltage protection, active input inrush current limiter, and overload/short-circuit protection. It supports series or parallel operation for increased output power and is resistant to back-feeding loads up to 50V. The efficiency rates are 0.952 at 3x480Vac input and 0.953 at 3x400Vac input. Peak inrush current consumption is 6A at both 3x400Vac and 3x480Vac inputs. The unit has a start-up delay of 500-600s, with rise times of 40ms and 45ms under specified conditions, and a hold time of 25ms. Power dissipation losses are 48.4W and 47.3W for 3x480Vac and 3x400Vac inputs, respectively, under full output load. Electrical durability spans from 363000 hours to 72000 hours across various conditions, with a ripple of 130mVpp at 20Hz to 20MHz and an output stage capacitance of 4700µF. | Puls | | |
| SLA4.100 PULS SLA4.100 is a power supply unit designed with a PFC compliant to EN 61000-3-2 standards, featuring a DC-OK relay contact output. It serves as an AS-Interface power supply unit (PSU) encased in a robust metal housing. This unit offers screw-clamp connections for secure installation and measures W73mm x H124mm x D102mm. It supports a wide range of supply voltages, including AC inputs from 85Vac-132Vac / 187Vac-264Vac across various nominal values and a DC input range of 240Vdc-300Vdc, with a rated current of 4A at 30.5Vdc. Designed for DIN rail mounting, it operates efficiently within an ambient air temperature range of -10...+70 °C. The SLA4.100 experiences a peak inrush current consumption of 49.7A at 230Vac input and 44.7A at 120Vac input, suitable for single-phase (1AC) or DC networks. It incorporates multiple protection functions, including output overvoltage protection up to 55Vdc max., NTC for input inrush current limiting, and overload/short-circuit protection with a current range of min. 4.2A to max. 6.5A, though it does not support series or parallel operation or ground-fault monitoring. The output voltage is fixed at 30.5Vdc, with an efficiency of 0.9 at 230Vac input, a hold time of 30ms at 100Vac input, power dissipation/losses at 13.5 W under full output load at 230Vac input, and a ripple of 50mVpp across 20Hz to 20MHz at 50Ω. | Puls | | |