FTCS-N1/2A4P-2AP8X-H1140 Turck Flow Sensors

Turck FTCS-N1/2A4P-2AP8X-H1140 FTCS-N1/2A4P-2AP8X-H1140 Flow Monitoring, Immersion Sensor with Integrated Processor
Turck

Part#:FTCS-N1/2A4P-2AP8X-H1140

Manufacturer:Turck

Alt. Part#:6870036

Product Lifecycle:Active

Get a quick Quote!

FTCS-N1/2A4P-2AP8X-H1140 Flow Monitoring, Immersion Sensor with Integrated Processor

About the manufacturer: Turck is one of the manufacturers that offers Flow Sensors that you can order at Powermatic Associates site. Turck is a leading provider of sensor, fieldbus, and connectivity technologies, along with interface technology, human-machine interfaces (HMI), and RFID systems. We offer innovative solutions for factory and process automation requirements, guaranteeing top-notch performance.

Check out the FTCS-N1/2A4P-2AP8X-H1140 Turck price in the box on the right side or send a quick quote.

Product Details

  • Weight
    427 g
  • Country Of Origin
    DEU
  • HTS Code
    9026102040
  • Protection class
    IP67
  • Medium temperature
    -20…+80 °C
  • Housing material
    Plastic, PBT
  • Function
    Flow monitoring
  • Sensor material
    Stainless steel
  • Design
    Immersion
  • Output function
    2 normally open contact, PNP
  • Electrical connection
    Connector, M12 × 1
  • Operating voltage
    19.2…28.8 VDC
  • Operating principle
    Calorimetric
  • Medium
    liquids
  • Process connection
    1/2” NPT

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


FTCS-N1/2A4P-2AP8X-H1140 Description

Turck FTCS-N1/2A4P-2AP8X-H1140 is a sensor from the FCS series designed for flow monitoring with a dual setpoint temperature setpoint feature. It is an instrumentation insertion probe flow monitor sensor/switch with two potentiometers. The sensor has a rectangular body made from PBT (Polybutylene Terephthalate) housing and 1.4571 (316Ti) stainless steel wetted parts, along with a Stainless steel 1.4305 / 303 connector. It comes pre-equipped with a 4-pin M12 Eurofast QD male connector and a 1/2" NPT threaded male process port for connections. The sensor offers protection functions against short-circuit (pulsed) and reverse polarity. It is capable of detecting flow rates of 1cm/s to 1.5m/s in water and 3cm/s to 3m/s in oil, withstanding pressures up to 100bar (1450psi). The supply voltage required is 21.6-26.4Vdc (24Vdc nom.), and it operates in medium temperatures of 0°C to +80°C and ambient air temperatures of -20°C to +70°C. The sensor is IP67 rated, consumes 60mA / 0.06A of current, and features 2 x digital outputs (20-30Vdc; PNP). Its response time ranges from 2-15 seconds at startup to 1-15 seconds during normal operation, with a control circuit rated current of 400mA / 0.4 A.



Related documents FTCS-N1/2A4P-2AP8X-H1140 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls