FCI-D09A4-NA-H1141/M16 Turck Flow Sensors

Turck FCI-D09A4-NA-H1141/M16 FCI-D09A4-NA-H1141/M16 Flow Monitoring, Inline Sensor without Integrated Processor
Turck

Part#:FCI-D09A4-NA-H1141/M16

Manufacturer:Turck

Alt. Part#:6870631

Product Lifecycle:Active

Get a quick Quote!

FCI-D09A4-NA-H1141/M16 Flow Monitoring, Inline Sensor without Integrated Processor

About the manufacturer: Turck is one of the manufacturers that offers Flow Sensors that you can order at Powermatic Associates site. Turck is a leading provider of sensor, fieldbus, and connectivity technologies, along with interface technology, human-machine interfaces (HMI), and RFID systems. We offer innovative solutions for factory and process automation requirements, guaranteeing top-notch performance.

Check out the FCI-D09A4-NA-H1141/M16 Turck price in the box on the right side or send a quick quote.

Product Details

  • Weight
    385 g
  • Protection class
    IP67
  • Ambient temperature
    -20…+70 °C
  • Sensor material
    Stainless steel
  • Housing material
    Stainless steel, 1.4571 (AISI 316Ti)
  • Medium temperature
    -20…+80 °C
  • Design
    Inline
  • Medium
    liquids
  • Electrical connection
    Connector, M12 × 1
  • Process connection
    M16 × 1.5
  • Function
    Flow monitoring
  • Operating principle
    Calorimetric

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


FCI-D09A4-NA-H1141/M16 Description

Turck FCI-D09A4-NA-H1141/M16 is a sensor designed for flow monitoring, featuring a 1.4571 (316Ti) stainless steel housing and wetted parts, with a stainless steel 1.4305 / 303 connector. It operates within an ambient air temperature range of -20°C to +70°C and offers a degree of protection of IP67. The sensor has a response time of 2-15 seconds during startup and 1-13 seconds during normal operation. It is designed with a rectangular body and is capable of monitoring flow rates of 30 to 900mL/min for water and 90mL/min to 1.8L/min for oil. This part of the FCI series functions as an instrumentation inline flow monitor sensor that requires a remote amplifier. It comes pre-equipped with a 4-pin M12 Eurofast QD male connector and an M16 threaded male process port. The sensor can withstand pressure up to 10bar (145psi) and requires a supply voltage of 21.6-26.4Vdc (24Vdc nominal). It is suitable for medium temperatures ranging from 0°C to +80°C.



Related documents FCI-D09A4-NA-H1141/M16 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1