LP4K0610EW3 Schneider Electric Industrial Automation Components


Part#:LP4K0610EW3
Manufacturer:Schneider Electric
Category:Industrial Automation Components
Product Lifecycle:Active
Get a quick Quote!
Schneider Electric LP4K0610EW3 is a magnetic contactor within the K sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 6A at 440Vac in AC-3 utilization category and offers a degree of protection of IP20. The control voltage (DC) ranges from 33.6 to 62.4Vdc, with a nominal value of 48Vdc (0.7...1.3 x Uc). Its rated operating voltage (Ue) reaches up to 690 V. This contactor includes 1 Normally Open (NO) auxiliary contact but does not have Normally Closed (NC) auxiliary contacts. It is capable of handling rated active power of 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all in AC-3. The mechanical durability of the LP4K0610EW3 is rated at 30 million operations at no load, with a phase-to-phase rated voltage (AC) of 690 V and a power consumption of 1.8 W.
About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the LP4K0610EW3 Schneider Electric price in the box on the right side or send a quick quote.
Product Details
- [Ui] Rated Insulation Voltage Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit
- Rated Breaking Capacity 110 A 415 V IEC 60947 110 A 440 V IEC 60947 80 A 500 V IEC 60947 110 A 220...230 V IEC 60947 110 A 380...400 V IEC 60947 70 A 660...690 V IEC 60947
- Flame Retardance V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
- Irms Rated Making Capacity 110 A AC power circuit NF C 63-110 110 A AC power circuit IEC 60947 110 A AC signalling circuit IEC 60947
- Operating Time 10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing
- Tightening Torque 11.51 lbf.in (1.3 N.m) screw clamp terminals Philips No 2 11.51 lbf.in (1.3 N.m) screw clamp terminals flat Ø 6 mm
- [Ith] Conventional Free Air Thermal Current 20 A 122 °F (50 °C) power circuit 10 A 122 °F (50 °C) signalling circuit
- Utilisation Category AC-3 AC-4
- Mounting Support Plate Rail
- Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Control Circuit Voltage Limits Operational 0.7...1.30 Uc 122 °F (50 °C)) Drop-out 0.1...0.7 Uc 122 °F (50 °C))
- Associated Fuse Rating 25 A gG <= 440 V power circuit 25 A aM power circuit 10 A gG signalling circuit IEC 60947 10 A gG signalling circuit VDE 0660
- [Ue] Rated Operational Voltage Power circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz
- Maximum Operating Rate 3600 cyc/h
- Net Weight 0.52 lb(US) (0.235 kg)
- Height 2.28 in (58 mm)
- Width 1.77 in (45 mm)
- Depth 2.24 in (57 mm)
- Insulation Resistance > 10 MOhm for signalling circuit
- Minimum Switching Voltage 17 V signalling circuit
- Minimum Switching Current 5 mA signalling circuit
- Mechanical Durability 30 Mcycles
- Hold-In Power Consumption In W 1.8 W 68 °F (20 °C)
- Inrush Power In W 1.8 W 68 °F (20 °C))
- Average Impedance 3 mOhm - Ith 20 A 50 Hz power circuit
- Overvoltage Category III
- [Uimp] Rated Impulse Withstand Voltage 8 kV
- Coil Technology Built-in bidirectional peak limiting diode suppressor
- Auxiliary Contact Composition 1 NO
- Auxiliary Contacts Type Instantaneous 1 NO
- [Ie] Rated Operational Current 6 A<= 440 V AC AC-3 power circuit
- Contactor Application Motor control
- Poles Description 3P
- Pole Contact Composition 3 NO
- Product Or Component Type Contactor
- Range Of Product TeSys K
- Range TeSys
- Device Short Name LP4K
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Related documents LP4K0610EW3 Specs
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.