LC1F4004F7 Schneider Electric Electronic Components

Schneider Electric LC1F4004F7 Schneider Electric LC1F4004F7 is a high-power magnetic contactor designed for surface mounting. It belongs to the F sub-range and features 4 poles (4NO) with ring-lugs/bar connections for installation. This contactor is rated for a current of 500A under AC-1 conditions and can operate at a control voltage ranging from 94-121Vac (110Vac nominal; 40-400Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 1000 V, and it has a rated impulse voltage (Uimp) of 8 kV. It is equipped with 0 Normally Open (NO) and 0 Normally Closed (NC) auxiliary contacts. The mechanical durability of the LC1F4004F7, at no load, is rated at 10,000,000 operations, and it supports a phase-to-phase rated voltage (AC) of 1000 V.
Schneider Electric

Part#:LC1F4004F7

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric LC1F4004F7 is a high-power magnetic contactor designed for surface mounting. It belongs to the F sub-range and features 4 poles (4NO) with ring-lugs/bar connections for installation. This contactor is rated for a current of 500A under AC-1 conditions and can operate at a control voltage ranging from 94-121Vac (110Vac nominal; 40-400Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 1000 V, and it has a rated impulse voltage (Uimp) of 8 kV. It is equipped with 0 Normally Open (NO) and 0 Normally Closed (NC) auxiliary contacts. The mechanical durability of the LC1F4004F7, at no load, is rated at 10,000,000 operations, and it supports a phase-to-phase rated voltage (AC) of 1000 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Electronic Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1F4004F7 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Standards
    JIS C8201-4-1 EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1
  • Product Certifications
    RINA RMRoS CB CCC DNV ABS LROS (Lloyds register of shipping) BV UL UKCA
  • [Icw] Rated Short-Time Withstand Current
    3600 A 104 °F (40 °C) - 10 s 2400 A 104 °F (40 °C) - 30 s 1700 A 104 °F (40 °C) - 1 min 1200 A 104 °F (40 °C) - 3 min 1000 A 104 °F (40 °C) - 10 min
  • Connections - Terminals
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
  • Tightening Torque
    Control circuit 10.62 lbf.in (1.2 N.m) Power circuit 309.78 lbf.in (35 N.m)
  • Operating Time
    40...65 ms closing 100...170 ms opening
  • Control Circuit Voltage Limits
    Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))
  • Associated Fuse Rating
    400 A aM <= 440 V 500 A gG <= 440 V
  • [Ue] Rated Operational Voltage
    <= 1000 V AC 50/60 Hz <= 460 V DC
  • [Ui] Rated Insulation Voltage
    1000 V IEC 60947-4-1 1500 V VDE 0110 group C
  • Maximum Operating Rate
    2400 cyc/h 131 °F (55 °C)
  • Compatibility Code
    LC1F
  • Heat Dissipation
    14 W
  • Mechanical Durability
    10 Mcycles
  • Hold-In Power Consumption In VA
    15 VA 40...400 Hz 0.9 68 °F (20 °C))
  • Inrush Power In VA
    1075 VA 40...400 Hz 0.9 68 °F (20 °C))
  • Mounting Support
    Plate
  • Power Dissipation Per Pole
    65 W AC-1
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV
  • Rated Breaking Capacity
    3200 A IEC 60947-4-1
  • Average Impedance
    0.26 mOhm - Ith 500 A 50 Hz
  • [Ith] Conventional Free Air Thermal Current
    500 A 104 °F (40 °C)
  • Overvoltage Category
    III
  • [Ie] Rated Operational Current
    500 A 104 °F (40 °C)) <= 440 V AC AC-1
  • [Uc] Control Circuit Voltage
    110 V AC 40...400 Hz
  • Contactor Application
    Resistive load
  • Product Or Component Type
    Contactor
  • Poles Description
    4P
  • Device Short Name
    LC1F
  • Power Pole Contact Composition
    4 NO
  • Utilisation Category
    AC-1
  • Range
    TeSys
  • Product Name
    TeSys F

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Manufacturer warranty

$2,133.00

Request a quote, and we will send availability within minutes.

Select Qty:

$2,133.00

$2,133.00 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls