EZM1400CBU300 Schneider Electric Electrical Load Centers

Schneider Electric

Part#:EZM1400CBU300

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Square D by Schneider Electric EZM1400CBU300 is a meter center main unit designed for surface mounting. It features a steel enclosure and aluminium busbar, ensuring durability and conductivity. With a degree of protection rated at NEMA 3R, it is suitable for both indoor and rainproof applications. The dimensions of this unit are H1753mm x W520mm x D292mm (H69.03" x W20.46" x D11.5"), and it operates at a rated voltage of 120Vac/240Vac. This single-phase (1PH-3W) metering center main unit is pre-equipped with a special LH incoming breaker. It supports a main rated current of 300A and a busbar rated current of 400A. The unit accommodates various cross-sections for aluminium/copper lugs, including 1 x 6AWG...300kcmil for ground, 1 x 1AWG...600kcmil and 2 x 1AWG...250kcmil for line, as well as 1 x 1AWG...600kcmil and 2 x 1AWG...250kcmil for neutral connections.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Electrical Load Centers that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the EZM1400CBU300 Schneider Electric price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


EZM1400CBU300 Description

Square D by Schneider Electric EZM1400CBU300 is a meter center main unit designed for surface mounting. It features a steel enclosure and aluminium busbar, ensuring durability and conductivity. With a degree of protection rated at NEMA 3R, it is suitable for both indoor and rainproof applications. The dimensions of this unit are H1753mm x W520mm x D292mm (H69.03" x W20.46" x D11.5"), and it operates at a rated voltage of 120Vac/240Vac. This single-phase (1PH-3W) metering center main unit is pre-equipped with a special LH incoming breaker. It supports a main rated current of 300A and a busbar rated current of 400A. The unit accommodates various cross-sections for aluminium/copper lugs, including 1 x 6AWG...300kcmil for ground, 1 x 1AWG...600kcmil and 2 x 1AWG...250kcmil for line, as well as 1 x 1AWG...600kcmil and 2 x 1AWG...250kcmil for neutral connections.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls