SCE-N3RFA1010-230 Saginaw Control Enclosure Fans

SCE-N3RFA1010-230 on Powermatic Associates
Saginaw Control

Part#:SCE-N3RFA1010-230

Manufacturer:Saginaw Control

Product Lifecycle:Active

Get a quick Quote!

Fan Assembly (230v) Type 3R, Height:12.80", Width:12.80", Depth:6.30",

About the manufacturer: Saginaw Control is one of the manufacturers that offers Enclosure Fans that you can order at Powermatic Associates site. For over five decades, Saginaw Control & Engineering has been a trusted name in the electrical sector, offering a wide range of standard and customized electrical enclosures. Situated in Saginaw, Michigan, our expansive 310,000 square feet manufacturing plant is where our products are expertly crafted.

Check out the SCE-N3RFA1010-230 Saginaw Control price in the box on the right side or send a quick quote.

Product Details

  • Width
    12.80"
  • Depth
    6.30"
  • Height
    12.80"
  • Industry Standards
    UL Component Recognized

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents SCE-N3RFA1010-230 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1