ASC-NCU-5-SP-132 NK Technologies Current Sensing Switches

ASC-NCU-5-SP-132 on Powermatic Associates
NK Technologies

Part#:ASC-NCU-5-SP-132

Manufacturer:NK Technologies

Product Lifecycle:Active

Get a quick Quote!

AC Current Switch, split core, 132 A factory calibrated setpoint, N.C. output, 0.3A, 135 VAC/VDC, 50 Hz

About the manufacturer: NK Technologies is one of the manufacturers that offers Current Sensing Switches that you can order at Powermatic Associates site. Maynard Kuljian founded Neilsen-Kuljian, Inc. in 1982 to address the demand for a more affordable way to measure current draw. The company was a trailblazer in creating cost-effective solid-state current sensing technology, which has since become a standard in the industry.

Check out the ASC-NCU-5-SP-132 NK Technologies price in the box on the right side or send a quick quote.

Product Details

  • Current Input
    132 A
  • Response Time
    120 ms
  • Supply Voltage
    self powered
  • Output Type
    1x N.C.
  • Case Style
    split core
  • Time Delay
    none

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents ASC-NCU-5-SP-132 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1