SP2201-HF Nidec Variable Frequency Drives (VFD)

SP2201-HF on Powermatic Associates
Nidec

Part#:SP2201-HF

Manufacturer:Nidec

Product Lifecycle:Active

Get a quick Quote!

NIDEC SP2201-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max in an open-loop configuration with a single Safe Torque Off (STO) and air cooling. It features a frame size 2 with dimensions of H15.32" x W6.1" x D8.62" (H389mm x W155mm x D219mm), and operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac). The rated current is 15.5A under normal duty and 12.6A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol, with a network frequency of 48-65 Hz on supply input and an output frequency range of 0-3000 Hz. The SP2201-HF includes 3 digital outputs (0-24Vdc; source), 1 digital output (2A / 240Vac; source; relay contact type), 3-phase input, 3 digital inputs (0-24Vdc), and analog inputs and outputs with varying specifications. The rated active power is 4kW for normal duty and 3kW for heavy-duty, corresponding to 5HP and 3HP respectively.

About the manufacturer: Nidec is one of the manufacturers that offers Variable Frequency Drives (VFD) that you can order at Powermatic Associates site. Control Techniques, a brand within Nidec, has been a pioneer in customer-focused drive technology for over four decades. Our dedication to advancing automation is demonstrated through our product innovation at our main office and across our 45 Automation Centers worldwide.

Check out the SP2201-HF Nidec price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


SP2201-HF Description

NIDEC SP2201-HF is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for high frequency applications up to 3000Hz max in an open-loop configuration with a single Safe Torque Off (STO) and air cooling. It features a frame size 2 with dimensions of H15.32" x W6.1" x D8.62" (H389mm x W155mm x D219mm), and operates on a supply voltage of 200Vac-240Vac (220Vac / 230Vac). The rated current is 15.5A under normal duty and 12.6A under heavy-duty conditions. This wall-mounted unit is designed to operate within an ambient air temperature range of 0°C to +40°C and has a degree of protection rated at IP20 NEMA 1. It supports Modbus RTU RS-485 communication protocol, with a network frequency of 48-65 Hz on supply input and an output frequency range of 0-3000 Hz. The SP2201-HF includes 3 digital outputs (0-24Vdc; source), 1 digital output (2A / 240Vac; source; relay contact type), 3-phase input, 3 digital inputs (0-24Vdc), and analog inputs and outputs with varying specifications. The rated active power is 4kW for normal duty and 3kW for heavy-duty, corresponding to 5HP and 3HP respectively.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1