F600-03400104A10101AB103 Nidec Variable Frequency Drives (VFD)

F600-03400104A10101AB103 on Powermatic Associates
Nidec

Part#:F600-03400104A10101AB103

Manufacturer:Nidec

Category:Variable Frequency Drives (VFD)

Product Lifecycle:Active

Get a quick Quote!

NIDEC F600-03400104A10101AB103 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for 3-phase input with a supply voltage range of 380Vac-480Vac, specifically 400Vac / 415Vac, and operates on a 60 Hz network frequency. It features a rated current of 10.4A and rated active power of 4kW, equivalent to 5HP under normal duty conditions. The device is equipped with 1 analog input (4-20mA / 0-10Vdc; single-ended), 1 analog output (0-10Vdc), 3 digital inputs (24Vdc and 0-24Vdc; configurable), and 2 digital outputs (240Vac; relay contact type). It supports Modbus RTU communication protocol. The F600 series inverter, with a built-in brake transistor, internal line choke, and air cooling, is designed for operation in ambient air temperatures ranging from -20°C to +40°C. It has an IP20 degree of protection and dimensions of frame size 3, measuring H15" x W3.3" x D7.9" (H382mm x W83mm x D200mm).

About the manufacturer: Nidec is one of the manufacturers that offers Variable Frequency Drives (VFD) that you can order at Powermatic Associates site. Control Techniques, a brand within Nidec, has been a pioneer in customer-focused drive technology for over four decades. Our dedication to advancing automation is demonstrated through our product innovation at our main office and across our 45 Automation Centers worldwide.

Check out the F600-03400104A10101AB103 Nidec price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


F600-03400104A10101AB103 Description

NIDEC F600-03400104A10101AB103 is a Variable Speed/Frequency Drive (VSD/VFD) / Inverter designed for 3-phase input with a supply voltage range of 380Vac-480Vac, specifically 400Vac / 415Vac, and operates on a 60 Hz network frequency. It features a rated current of 10.4A and rated active power of 4kW, equivalent to 5HP under normal duty conditions. The device is equipped with 1 analog input (4-20mA / 0-10Vdc; single-ended), 1 analog output (0-10Vdc), 3 digital inputs (24Vdc and 0-24Vdc; configurable), and 2 digital outputs (240Vac; relay contact type). It supports Modbus RTU communication protocol. The F600 series inverter, with a built-in brake transistor, internal line choke, and air cooling, is designed for operation in ambient air temperatures ranging from -20°C to +40°C. It has an IP20 degree of protection and dimensions of frame size 3, measuring H15" x W3.3" x D7.9" (H382mm x W83mm x D200mm).


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1