8086603 Festo Electrical Peripheral Devices
Part#:8086603
Manufacturer:Festo
Alt. Part#:CPX-AP-I-4DI4DO-M12-5P
Product Lifecycle:Active
Get a quick Quote!
digital input/output module CPX-AP-I-4DI4DO-M12-5P Dimensions W x L x H: 30 mm x 170 mm x 35 mm, No. of outputs: 4, No. of inputs: 4, Diagnostics via LED: (* Diagnostics per module, * Power supply load, * Status per channel), Diagnostics per internal comm
About the manufacturer: Festo is one of the manufacturers that offers Electrical Peripheral Devices that you can order at Powermatic Associates site. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.
Check out the 8086603 Festo price in the box on the right side or send a quick quote.
Product Details
- Diagnose per internal communication Load switch-off Load undervoltage
- Permissible voltage fluctuations for electronics/sensors ± 25 %
- Electrical connection output, connection technology M12x1 A-coded as per EN 61076-2-101
- Digital inputs, electrical isolation of input - internal communication yes
- Electrical isolation of outputs between channel - internal communication yes
- Nominal operating voltage DC for electronics/sensors 24 V
- Electrical output connection, number of pins/wires 5
- Max. residual current of outputs per module 2 A
- Switching level Signal 0: <= 5 V Signal 1: >= 11 V
- Degree of protection IP65 IP67
- Characteristic curve outputs As per IEC 61131-2, type 0.5
- Input characteristics As per IEC 61131-2, type 3
- KC characters KC EMC
- Note on degree of protection Unused connections sealed
- Power supply, connection technology M8x1, A-coded as per EN 61076-2-104
- Relative air humidity 5 - 95 % Non-condensing
- Communication interface, connection type 2x socket
- Communication interface, function System communication XF10 IN / XF20 OUT
- Communication interface, protocol AP-COM
- Diagnostics via LED Diagnostics per module Status per channel
- Voltage forwarding, function Outgoing electronics/sensors and load
- Voltage forwarding, number of pins/wires 4
- Power supply, number of pins/wires 4
- Nominal operating voltage DC load 24 V
- Note regarding operating voltage SELV/PELV fixed power supplies required Note voltage drop
- Corrosion resistance class (CRC) 1 - Low corrosion stress
- Product weight 129 g
- Type of mounting With through-hole
- Housing material PA Die-cast zinc, nickel-plated
- Fuse protection inputs (short circuit) Internal electronic fuse per module
- Power supply, function Incoming electronics/sensors and load
- Information on max. cable length Power supply according to nominal voltage
- Power supply, type of connection Plug
- Electrical isolation of inputs between channels no
- Electrical connection input, connection type 2x socket
- Electrical connection, input, number of pins/wires 5
- Max. residual current of inputs per module 1.8 A
- CE marking (see declaration of conformity) As per EU EMC directive
- Input switching logic PNP (positive switching) 3-wire sensors as per IEC 61131-2
- Max. power supply 2 x 4 A (external fuse required)
- Fuse protection outputs (short circuit) Internal electronic fuse per channel
- Voltage forwarding, connection technology M8x1, A-coded as per EN 61076-2-104
- Intrinsic current consumption at nominal operating voltage load Typically 10 mA
- Max. power supply per channel 0.5 A
- Voltage forwarding, connection type Socket
- Electrical connection input, function Digital input
- Electrical connection output, function Digital output
- Communication interface, shielding yes
- Communication interface, number of pins/wires 4
- Reverse polarity protection yes
- Type code CPX-AP-I
- Ambient temperature -20 °C ... 50 °C
- Switching logic at outputs PNP (positive switching)
- Dimensions W x L x H 30 mm x 170 mm x 35 mm
- Electrical connection output, connection type 2x socket
- Communication interface, connection technology M8x1, D-coded as per EN 61076-2-114
- Electrical isolation of outputs between channels no
- Output delay with resistive load Signal change 0->1: < 200 µs Signal change 1->0: < 200 µs
- Intrinsic current consumption at nominal operating voltage for electronics/sensors Typically 35 mA
- Max. cable length 30 m outputs 50 m system communication
- Permissible voltage fluctuations load ± 25 %
- Electrical input connection, connection technology M12x1 A-coded as per EN 61076-2-101
- No. of outputs 4
- No. of inputs 4
- Power failure buffering 10 ms
- Input debounce time 0.1 ms 20 ms
- Storage temperature -40 °C ... 70 °C
- Certification RCM compliance mark
- Note on materials RoHS-compliant
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Related documents 8086603 Specs
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Worldwide Shipping and Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Got Questions? We've Got Answers!
Need more details?
Feel free to chat with us
What can I help you find today?