8058469 Festo Flow Sensors

Festo 8058469 flow sensor SFAH-10U-Q6S-PNLK-PNVBA-L1 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Certificate issuing department: UL
Festo

Part#:8058469

Manufacturer:Festo

Alt. Part#:SFAH-10U-Q6S-PNLK-PNVBA-L1

Product Lifecycle:Active

Get a quick Quote!

flow sensor SFAH-10U-Q6S-PNLK-PNVBA-L1 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Certificate issuing department: UL

About the manufacturer: Festo is one of the manufacturers that offers Flow Sensors that you can order at Powermatic Associates site. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8058469 Festo price in the box on the right side or send a quick quote.

Product Details

  • Electrical connection 1, number of pins/wires
    4
  • Idle current
    ≤ 25 mA
  • Flow direction
    Unidirectional
  • Method of measurement
    Heat transfer
  • Nominal temperature
    23 °C
  • Accuracy of flow rate
    ± (2% o.m.v. + 1% FS)
  • Flow characteristic curve, end value
    10 l/min
  • Max. load resistance of current output
    500 Ohm
  • IO-Link®, port class
    A
  • Protection against tampering
    IO-Link® PIN code
  • Electrical connection 1, connection technology
    Connection diagram L1J
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Measuring principle
    Thermal
  • Ambient temperature
    0 °C ... 50 °C
  • Zero point repetition accuracy in ± %FS
    0.2 %FS
  • Switching output
    2 x PNP or 2 x NPN switchable
  • Switching element function
    N/C contact/N/O contact switchable
  • Short-circuit protection
    yes
  • IO-Link®, protocol version
    Device V 1.1
  • IO-Link®, SIO mode support
    Yes
  • IO-Link®, process data width IN
    3 Byte
  • Reverse polarity protection
    for all electrical connections
  • Product weight
    60 g
  • Setting options
    IO-Link® Via display and pushbuttons
  • Protection class
    III
  • Type code
    SFAH
  • Electrical connection for input 1, connection pattern
    00995428
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Note on materials
    RoHS-compliant
  • Measured variable
    Mass flow rate Volumetric flow rate
  • Temperature of medium
    0 °C ... 50 °C
  • Temperature co-efficient margin in ± %FS/K
    typ. 0.15% FS/K
  • Max. output current
    100 mA
  • Protocol
    IO-Link®
  • IO-Link®, minimum cycle time
    4 ms
  • Pneumatic connection
    For pneumatic tubing outside diameter 6 mm
  • Degree of protection
    IP40
  • Electrical connection 1, connection type
    Plug
  • Symbol
    00995795
  • Certificate issuing authority
    UL E322346
  • Operating medium
    Argon Nitrogen
  • Pressure influence of margin in ±%FS/bar
    1 %FS/b.
  • Switching function
    Window comparator Auto difference monitoring
  • Flow characteristic curve, start value
    0 l/min
  • Overload protection
    Available
  • IO-Link®, function classes
    Binary data channel (BDC) Teach channel
  • IO-Link®, process data content IN
    1 bit BDC (volume monitoring) 2 bit BDC (flow monitoring)
  • DC operating voltage range
    22 V ... 26 V
  • Display type
    Illuminated LCD, multi-color
  • Displayable unit(s)
    g scft/min
  • Pneumatic connection, outlet direction
    Straight
  • KC characters
    KC EMC
  • Flow measuring range start value
    0.2 l/min
  • Operating pressure
    -0.9 bar ... 10 bar
  • Flow measuring range end value
    10 l/min
  • Repetition accuracy margin in ± %FS
    0.8 %FS
  • Analog output
    0 - 10 V 1 - 5 V
  • Min. load resistance of voltage output
    20 kOhm
  • IO-Link®, profile
    Smart sensor profile
  • IO-Link®, communication mode
    COM2 (38,4 kBd)
  • IO-Link®, service data contents IN
    32 bit volume/mass measurement
  • Type of mounting
    With accessories
  • Materials in contact with the media
    Wrought aluminum alloy, anodized High-alloy stainless steel
  • Pressure drop
    < 5 mbar
  • IO-Link®, data memory required
    < 500 byte
  • Mounting position
    Any
  • Housing material
    PA-reinforced
  • Corrosion resistance class (CRC)
    2 - Moderate corrosion stress

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents 8058469 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1