semi-rotary drive DFPD-20-RP-90-RS30-F05-R3-EP single-acting, rack and pinion design, connection pattern to NAMUR VDI/VDE 3845 for mounting solenoid valves, position sensors and positioners, standard connection to process valve fitting ISO 5211, epoxy coa

About the manufacturer: Festo is one of the manufacturers that offers Quarter Turn Actuators that you can order at Powermatic Associates site. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8048016 Festo price in the box on the right side or send a quick quote.

Product Details

  • Size of valve actuator
    20
  • Safety function
    The fundamental safety function is that the control valve moves to the switching position when the compressed air is turned off. It is reset by spring force.
  • Swivel angle
    90 deg
  • Depth shaft connection
    12 mm
  • Mode of operation
    Single-acting
  • Symbol
    00991266
  • ATEX category for dust
    II 2D
  • Certificate issuing authority
    DNVGL TAP00001CE German Technical Control Board (TÜV) Rheinland 968/V 1106.00/19
  • CE marking (see declaration of conformity)
    as per EU explosion protection directive (ATEX)
  • Spring return torque with 90° swivel angle
    7.1 Nm
  • Note on materials
    RoHS-compliant
  • Seals material
    NBR
  • Material of bearing
    POM
  • Operating pressure
    2 bar ... 8 bar
  • MTTFd
    1126 years
  • End-position adjusting range at 0°
    -5 deg ... 5 deg
  • Type code
    DFPD
  • Standard connection for valve
    ISO 5211
  • Certified for safety function to ISO 13849 and IEC 61508 (SIL)
    Product can be used in safety-related parts of control systems up to SIL 2, low demand up to SIL 3 in a redundant architecture
  • Type of ignition protection for gas
    Ex h IIC T4 Gb X
  • Explosive ambient temperature
    -20°C <= Ta <= +80°C
  • Spring return torque at 0° swivel angle
    3.6 Nm
  • Pneumatic connection
    G1/8
  • Material of piston
    Die-cast aluminum
  • Maritime classification
    See certificate
  • Flange hole pattern
    F05
  • Design
    Gear rack/pinion
  • Safety integrity level (SIL)
    Up to SIL 2 low demand mode up to SIL 1 high demand mode
  • ATEX category gas
    II 2G
  • Operating medium
    Compressed air as per ISO 8573-1:2010 [7:4:4]
  • Storage temperature
    -20 °C ... 60 °C
  • Torque at nominal operating pressure and 0° swivel angle
    7.4 Nm
  • Product weight
    1371 g
  • Shaft connection
    T11
  • Material of screws
    High-alloy stainless steel
  • Nominal operating pressure
    3 bar
  • End-position adjusting range at nominal swivel angle
    -5 deg ... 5 deg
  • Closing direction
    Clockwise closing
  • Connection for valve positioner and position sensor conforms to standard
    VDI/VDE 3845 size AA 1
  • Ambient temperature
    -20 °C ... 80 °C
  • Information on operating and pilot media
    Dew point min. 10 °C below the ambient and medium temperature Operation with oil lubrication possible (required for further use)
  • Torque at nominal operating pressure and 90° swivel angle
    3.8 Nm
  • PFD
    7.8E-4
  • Material of sub-base
    Wrought aluminum alloy, anodized
  • Material of spring
    Spring steel
  • Cam material
    Cast stainless steel
  • Devices type according to VDMA 66413
    Safety device
  • PFH
    1.01E-7
  • Mounting position
    Any
  • Valve connection conforms to standard
    VDI/VDE 3845 (NAMUR)
  • Type of (ignition) protection for dust
    Ex h IIIC T105°C Db X
  • Explosion prevention and protection
    Zone 1 (ATEX) Zone 22 (ATEX)
  • Corrosion resistance class (CRC)
    2 - Moderate corrosion stress
  • Note about the torque
    The actuator's operating torque must not be higher than the maximum permissible torque listed in ISO 5211, based on the size of the mounting flange and the coupling.
  • Air consumption at 6 bar per cycle 0°-nominal swivel angle-0°
    0.8 l
  • Cover material
    Die-cast aluminum, coated
  • Housing material
    Wrought aluminum alloy, anodized
  • Shaft material
    High-alloy stainless steel

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Related documents 8048016 Specs

Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1