PDIL26ULLD-VL Banner Through Beam Sensors

PDIL26ULLD-VL on Powermatic Associates
Banner

Part#:PDIL26ULLD-VL

Manufacturer:Banner

Category:Through Beam Sensors

Alt. Part#:812164

Product Lifecycle:Active

Get a quick Quote!

Plastic Fiber; Convergent; Core Dia.: 0.5 mm; Fiber Length 2 m; Liquid Level Sensing, Tube Mount; Free cut; Vantage Line

About the manufacturer: Banner is one of the manufacturers that offers Through Beam Sensors that you can order at Powermatic Associates site. Banner Engineering Corp. is a globally renowned leader in the industrial automation sector. Our diverse product line, comprising sensors, vision sensors, LED lights, indicators, wireless devices, and safety products, caters to businesses of all sizes worldwide.

Check out the PDIL26ULLD-VL Banner price in the box on the right side or send a quick quote.

Product Details

  • Weight
    17.690088 g
  • Country Of Origin
    TW
  • Max Distance: DF-G1 (mm)
    No Data
  • Max Distance: DF-G2 (mm)
    No Data
  • Max Distance: DF-G3 (mm)
    No Data
  • Fiber Sensing End Size - Mounting Area
    15.5 x 22.0 mm
  • Measured Max Distance (mm)
    No Data
  • Tariff Fiber Meters (fbm)
    10
  • Termination Type
    Plastic Fiber Sensors
  • Application: Vacuum Feed Through
    None
  • Feature: Small Object Detection
    No
  • Application: Liquid Level
    Yes
  • Feature: Chemical Resistant
    No
  • Integrated Lens
    No
  • Minimum Repeat Bending Endurance
    1000
  • Max Temp ( °C)
    70
  • Termination
    Free Cut
  • Fiber Length (m)
    2
  • Core Diameter (mm)
    0.5
  • Minimum Bend Radius (mm)
    2
  • Retractile
    No
  • Sensing End Segment 1
    Specialty
  • Fiber Sensing End Size
    15.5 x 22.0 mm
  • Flex Relief
    No
  • Fiber Sensing End Tip
    Specialty
  • Beam Exit
    Right Angle
  • Housing Style
    Fixtured
  • Fiber Sheathing Material (Jacket)
    Polyethylene
  • Sensing Mode (Detailed)
    Slot
  • Quantity Included
    1
  • Sensing End Material (Specific)
    Polyethylene
  • Sensing Mode (General)
    Opposed
  • Fiber Optic Type
    Plastic

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


PDIL26ULLD-VL Description

Banner Engineering PDIL26ULLD-VL is a fiber optic sensor designed for precise detection tasks. It operates within an ambient air temperature up to +70°C and features a through-beam system, also known as an opposed mode flex strain relief pair of individual fibers, with side/right-angled sensing. The sensor has a 0.25mm fiber core diameter and is part of the Plastic fiber series. Its slot shape is complemented by a durable zinc alloy sensing end and a plastic fiber with a polyethylene (PE) fiber sheath. The total length of the sensor is 6ft / 2m, accommodating various installation requirements.


Manufacturer warranty

$206.00

Request a quote, and we will send availability within minutes.

Select Qty:

$206.00

$206.00 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1