1SAM301901R1003 ABB Control Circuit Protection Accessories

1SAM301901R1003 on Powermatic Associates
ABB Control

Part#:1SAM301901R1003

Manufacturer:ABB Control

Product Lifecycle:Active

Get a quick Quote!

ABB 1SAM301901R1003 is an auxiliary contact designed for right-side-mounting as a signaling contact/switch block with screw-clamp connections. It operates with a rated voltage of 600Vdc and is specifically designed for short-circuit alarm functions. This model features 2NC (Normally Closed) contacts and does not include Normally Open (NO) auxiliary contacts. It is suitable for use within an ambient air temperature range for operation of -25 to +60°C and for storage from -50 to +80°C. The part has an IP20 control voltage rating, a rated impulse voltage (Uimp) of 6 kV, and a rated insulation voltage (Ui) of 690 V. It is designed to withstand up to 50,000 operations, indicating its operational lifespan. The net dimensions include a width of 9 mm, a depth of 78 mm, and a length indicating operational cycles of 50,000 operations. This auxiliary contact is equipped for short circuit protection and phase failure, supporting a primary current of 690 V.

About the manufacturer: ABB Control is one of the manufacturers that offers Circuit Protection Accessories that you can order at Powermatic Associates site. ABB's Industrial Automation division offers a variety of solutions designed for process and hybrid industries, including industry-specific integrated automation, electrification, and digital solutions, control technologies, software, and advanced services.

Check out the 1SAM301901R1003 ABB Control price in the box on the right side or send a quick quote.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


1SAM301901R1003 Description

ABB 1SAM301901R1003 is an auxiliary contact designed for right-side-mounting as a signaling contact/switch block with screw-clamp connections. It operates with a rated voltage of 600Vdc and is specifically designed for short-circuit alarm functions. This model features 2NC (Normally Closed) contacts and does not include Normally Open (NO) auxiliary contacts. It is suitable for use within an ambient air temperature range for operation of -25 to +60°C and for storage from -50 to +80°C. The part has an IP20 control voltage rating, a rated impulse voltage (Uimp) of 6 kV, and a rated insulation voltage (Ui) of 690 V. It is designed to withstand up to 50,000 operations, indicating its operational lifespan. The net dimensions include a width of 9 mm, a depth of 78 mm, and a length indicating operational cycles of 50,000 operations. This auxiliary contact is equipped for short circuit protection and phase failure, supporting a primary current of 690 V.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts

UBC10.241 on Powermatic Associates

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.

Puls

1