Manufacturer
Turck
Signal Conditioners
Turck

Signal Conditioners - Turck

Devices involved in the manipulation of the analog signal output from sensors in preparation for the next stage of processing.

Turck
Turck

Found 16 products

IMS-AI-UNI/24V
Turck

Analog signal isolator, 1-channel, , Input circuit: 0/4…20 mA or 0…10 V, Output circuit: 0/4…20 mA or 0…10 V, Type of input and output signal adjusted via DIP switch, Accuracy, , Complete galvanic isolation, Input reverse-polarity protected, 6.2 mm width, UL: Class1, Div 2, Group A, B, C, D; GOST

Quick Quote

MS24-R
Turck

Rotation speed monitor, 1-channel, , Monitoring range: 10 mHz… 1 666 Hz (0.6…100 000, min-1, ), Line monitored for wire-break/short-circuit, 1 limit value relay and 1 alarm relay, Setting of digital limit values in Hz or min, ‐1, Start-up bypass activatable for underspeed monitoring, Dynamic monitoring of input circuit, activatable for overspeed monitoring, Removable terminal blocks, Excellent temperature stability and repeatability, Two sealed relays with hard gold contact (1 x limit value, 1 x

Quick Quote

Turck

Turck MS41-42EX0-R is an interface unit designed for DIN rail mounting, featuring a logic amplifier relay function. It operates within an ambient air temperature range of -25 to +60°C and has a net height of 75 mm, a net width of 50 mm, and a net depth of 110 mm. This 4-channel device offers connectivity through 2 x 8-pin removable terminal screw connections. It supports a supply voltage range of 20-250Vac (with 24Vac, 120Vac, 220Vac, and 240Vac nominal values) and 20-125Vdc (with 24Vdc, 110Vdc, and 120Vdc nominal values). The MS41-42EX0-R is housed in a polycarbonate/ABS material and is rated with an IP20 degree of protection. It features 2 x digital outputs (2 relay changeover C/O SPDT contact) and 1 x digital input (NAMUR), with protection functions including reverse polarity.

Quick Quote

Turck

Level Controller, 1-channel

Quick Quote

Turck

Turck MK15-12EX0-PN/24VDC is an interface unit designed for DIN rail mounting, featuring an isolating switching amplifier function. It operates within an ambient air temperature range of -25 to +60°C and has dimensions of 89 mm in height, 18 mm in width, and 70 mm in depth. This 1-channel ATEX compliant device offers flat screw terminal connections with self-lifting pressure plates for secure connectivity. It belongs to the MK series and is protected by an IP20 rated polycarbonate/ABS housing. The unit is powered by a supply voltage of 10-30Vdc, with 12Vdc and 24Vdc as nominal values. It includes 2 x digital outputs (PNP/NPN transistor outputs; normally open or normally closed parametrizable; short-circuit protected) and 1 x digital input (NAMUR; 8.2Vdc), featuring protection functions against short-circuits.

Quick Quote

Turck

Turck MK15-12EX0-PN/24VDC/K11 is an interface unit designed for DIN rail mounting, featuring an isolating switching amplifier function. It operates within an ambient air temperature range of -25 to +60°C and has a net height of 89 mm, width of 18 mm, and depth of 70 mm. This 1-channel ATEX compliant device offers flat screw terminal connections with self-lifting pressure plates for secure connectivity. Part of the MK series, it has an IP20 degree of protection and requires a supply voltage of 10-30Vdc, with 12Vdc and 24Vdc as nominal values. The housing is made from a combination of polycarbonate and ABS materials. It includes 2 digital outputs (PNP/NPN transistor outputs; NO or NC parametrizable; short-circuit protected) and 1 digital input (NAMUR; 8.2Vdc), with protection functions against short-circuit.

Quick Quote

ItemManufacturerPriceStockDelivery
IMS-AI-UNI/24V

IMS-AI-UNI/24V

Analog signal isolator, 1-channel, , Input circuit: 0/4…20 mA or 0…10 V, Output circuit: 0/4…20 mA or 0…10 V, Type of input and output signal adjusted via DIP switch, Accuracy, , Complete galvanic isolation, Input reverse-polarity protected, 6.2 mm width, UL: Class1, Div 2, Group A, B, C, D; GOST

Turck

Quick Quote

MS24-R

MS24-R

Rotation speed monitor, 1-channel, , Monitoring range: 10 mHz… 1 666 Hz (0.6…100 000, min-1, ), Line monitored for wire-break/short-circuit, 1 limit value relay and 1 alarm relay, Setting of digital limit values in Hz or min, ‐1, Start-up bypass activatable for underspeed monitoring, Dynamic monitoring of input circuit, activatable for overspeed monitoring, Removable terminal blocks, Excellent temperature stability and repeatability, Two sealed relays with hard gold contact (1 x limit value, 1 x

Turck

Quick Quote

MS41-42EX0-R

Turck MS41-42EX0-R is an interface unit designed for DIN rail mounting, featuring a logic amplifier relay function. It operates within an ambient air temperature range of -25 to +60°C and has a net height of 75 mm, a net width of 50 mm, and a net depth of 110 mm. This 4-channel device offers connectivity through 2 x 8-pin removable terminal screw connections. It supports a supply voltage range of 20-250Vac (with 24Vac, 120Vac, 220Vac, and 240Vac nominal values) and 20-125Vdc (with 24Vdc, 110Vdc, and 120Vdc nominal values). The MS41-42EX0-R is housed in a polycarbonate/ABS material and is rated with an IP20 degree of protection. It features 2 x digital outputs (2 relay changeover C/O SPDT contact) and 1 x digital input (NAMUR), with protection functions including reverse polarity.

Turck

$547.60

Quick Quote

MK91-12-R/115VAC

Level Controller, 1-channel

Turck

Quick Quote

MK15-12EX0-PN/24VDC

Turck MK15-12EX0-PN/24VDC is an interface unit designed for DIN rail mounting, featuring an isolating switching amplifier function. It operates within an ambient air temperature range of -25 to +60°C and has dimensions of 89 mm in height, 18 mm in width, and 70 mm in depth. This 1-channel ATEX compliant device offers flat screw terminal connections with self-lifting pressure plates for secure connectivity. It belongs to the MK series and is protected by an IP20 rated polycarbonate/ABS housing. The unit is powered by a supply voltage of 10-30Vdc, with 12Vdc and 24Vdc as nominal values. It includes 2 x digital outputs (PNP/NPN transistor outputs; normally open or normally closed parametrizable; short-circuit protected) and 1 x digital input (NAMUR; 8.2Vdc), featuring protection functions against short-circuits.

Turck

Quick Quote

MK15-12EX0-PN/24VDC/K11

Turck MK15-12EX0-PN/24VDC/K11 is an interface unit designed for DIN rail mounting, featuring an isolating switching amplifier function. It operates within an ambient air temperature range of -25 to +60°C and has a net height of 89 mm, width of 18 mm, and depth of 70 mm. This 1-channel ATEX compliant device offers flat screw terminal connections with self-lifting pressure plates for secure connectivity. Part of the MK series, it has an IP20 degree of protection and requires a supply voltage of 10-30Vdc, with 12Vdc and 24Vdc as nominal values. The housing is made from a combination of polycarbonate and ABS materials. It includes 2 digital outputs (PNP/NPN transistor outputs; NO or NC parametrizable; short-circuit protected) and 1 digital input (NAMUR; 8.2Vdc), with protection functions against short-circuit.

Turck

Quick Quote

Signal Conditioners

General Guide & Overview

Signal conditioning is an essential part of the data acquisition process, as it prepares analog signals from sensors for further processing and conversion into digital form. It manipulates the signal to enhance its quality and ensure accurate measurements. Signal conditioners are used in various industries and applications, such as temperature and vibration measurements. They are crucial in enhancing sensor performance and ensuring precise data in industrial applications. This guide will provide a general overview of signal conditioners and their role in the measurement process.

Introduction to Signal Conditioners

Signal conditioners are electronic circuits that manipulate signals to prepare them for the next stage of processing. They play a crucial role in enhancing the accuracy and reliability of sensor measurements by addressing the specific requirements of different sensors.

Sensor conditioning is necessary for various types of sensors, including thermocouples, RTDs, accelerometers, strain gauges, and load cells. These sensors have unique characteristics, such as different voltage levels, sensitivities, and output types, which need to be manipulated to ensure compatibility with data acquisition devices.

Types and Functions of Signal Conditioners

Signal conditioners are essential components in the field of sensor signal conditioning. They come in various types, each designed to cater to specific sensor requirements. These signal conditioners play a crucial role in enhancing the accuracy and reliability of sensor measurements.

Some common types of signal conditioners include:

Voltage and high-voltage signal conditioners

Current signal conditioners

IEPE signal conditioners

Charge signal conditioners

Strain gauge signal conditioners

2Load cell signal conditioners

Thermocouple signal conditioners

RTD signal conditioners

LVDT signal conditioners

Each type of signal conditioner provides various essential functions to ensure accurate and reliable measurements. These functions include:

Amplification: Signal conditioners amplify weak sensor signals to a level suitable for further processing.

Filtering: They filter out noise and interference, ensuring clean and precise signals.

Isolation: Signal conditioners provide isolation to protect the connected equipment from electrical interference.

Range selection: They allow for the selection of appropriate measuring ranges, ensuring optimal performance.

Signal conditioners can be standalone modules or integrated into larger signal conditioning systems. The choice depends on the specific application requirements and scalability. Additionally, programmable signal conditioners offer customization and flexibility in signal processing, allowing for tailored solutions.

Overall, signal conditioners are vital components in sensor signal conditioning systems, enabling accurate and reliable measurements across a wide range of industries and applications.

Signal conditioners play a crucial role in the measurement process, ensuring accurate and reliable data acquisition. They are responsible for preparing analog signals from sensors for conversion into digital form, taking into account the specific requirements and characteristics of each sensor.

Signal conditioning involves several key steps to enhance the quality and accuracy of the signals. Weak signals are amplified to ensure they can be accurately measured, while noise and interference are filtered out to eliminate any distortions. The signal conditioners also provide suitable connectors to facilitate seamless integration between sensors and data acquisition devices.

Load cells, a type of sensor commonly used in industrial applications, are a perfect example of how signal conditioners work. Load cells measure the force exerted by an object and generate an analog signal. The signal conditioner ensures that the load cell's analog signal is properly amplified, filtered, and calibrated before being converted into a digital signal that can be processed by data acquisition devices.

In summary, signal conditioners are essential for accurate and reliable measurements. They manipulate signals from sensors to enhance their quality, taking into account the specific requirements of each sensor. Whether it's load cells or other types of sensors, signal conditioners are crucial in ensuring precise and reliable data in various industrial applications.

FAQ

Signal conditioning is the process of manipulating analog signals from sensors to prepare them for further processing and conversion into digital form. It involves amplifying, filtering, and converting signals to ensure accuracy and compatibility with data acquisition devices.

Signal conditioners are used to enhance the accuracy and reliability of sensor measurements in various industries and applications, such as temperature and vibration measurements. They are essential in improving sensor performance and ensuring precise data in industrial settings.

Signal conditioners come in various types, including voltage, current, IEPE, charge, strain gauge, load cell, thermocouple, RTD, and LVDT signal conditioners. These conditioners provide functions such as amplification, filtering, isolation, and range selection, catering to the specific requirements of different sensors.

Signal conditioners work by manipulating analog signals from sensors through processes such as amplification, filtering, and isolation. They ensure compatibility with data acquisition devices by addressing the specific requirements and characteristics of each sensor, resulting in accurate and reliable data acquisition.

Load cells, which are sensors used for measuring force or weight, require signal conditioners to enhance their performance and ensure accurate measurements. Signal conditioners amplify and filter the electrical signals produced by load cells, making them compatible with data acquisition devices for precise data acquisition.