Manufacturer
Turck
Signal Conditioners
Turck

Signal Conditioners - Turck

Devices involved in the manipulation of the analog signal output from sensors in preparation for the next stage of processing.

Turck
Turck

Found 16 products

MS27-R
MS27-R$797.30
Turck

Zero-speed Monitor, 1-channel, , Rotation underspeed monitoring, Monitoring range: 25 mHz… 166 Hz (1.5…10 000, min-1, ), Removable terminal blocks, Start-up bypass, activatable, Adjustable switch-off delay, Two sealed relays with hard gold contact (1 x limit value, 1 x alarm), Complete galvanic isolation, Input reverse-polarity protected

Quick Quote

MK91-R11/24VDC
Turck

Level controller, 1-channel, , Switching point at 40 k, Ω, Hysteresis approx. 5%, Output: Relay with 1 changeover contact, Complete galvanic isolation, Input reverse-polarity protected

Quick Quote

MS24-112-R
MS24-112-R$922.40
Turck

Rotation speed monitor, 1-channel, , Rotation speed monitoring for overspeed or underspeed, Monitoring range: 25 mHz…50 Hz (1.5…3 000), min-1, ), Line monitored for wire-break/short-circuit, Removable terminal blocks, One relay output as changeover contact, Start-up bypass, activatable, Complete galvanic isolation, Input reverse-polarity protected

Quick Quote

MK91-121-R/24VDC
Turck

Level controller, 1-channel, , Responsivity: 0.2…100 k, Ω, Hysteresis: 10%, Output: 2 relays with 1 changeover contact, Electronic switching of electrodes, Switch-on/off delay 0…20 s, separately adjustable, Reliable distinction between foam and liquid, Galvanic isolation of input circuits, output circuits and power supply

Quick Quote

IMS-AI-DLI-22-DLI/L
Turck

Analog signal isolator, 2-channel, , Input circuits: 0/4…20 mA, Output circuits: 0/4…20 mA, Accuracy, , Complete galvanic isolation, Input reverse-polarity protected, 6.2 mm width, UL: Class1, Div 2, Group A, B, C, D; GOST

Quick Quote

MS23-R
Turck

Rotation direction discriminator, 1-channel, , Rotation direction discriminator, Adjustable switch-off delay, Removable terminal blocks, Complete galvanic isolation, Input reverse-polarity protected

Quick Quote

IMS-TI-PT100/24V
Turck

Temperature measuring amplifier, 1-channel, , Connection of temperature probe Pt100, Output circuit: 0/4…20 mA or 0…10 V, Accuracy, , Complete galvanic isolation, Input reverse-polarity protected, 6.2 mm width, UL: Class1, Div2, Group A, B, C, D; GOST

Quick Quote

MK91-12-R/230VAC
Turck

Level controller, 1-channel, , Responsivity: 0.2…100 k, Ω, Hysteresis: 10%, Output: 2 relays with 1 changeover contact, Electronic switching of electrodes, Switch-on/off delay 0…20 s, separately adjustable, Reliable distinction between foam and liquid, Galvanic isolation of input circuits, output circuits and power supply

Quick Quote

MS91-12-R
Turck

Level controller, 1-channel, , Output: 2 relays with changeover contact, Responsivity: 0.2…100 k, Ω, , Removable terminal blocks, Switching of electrodes via auxiliary relay, Switch-on/off delay adjustable 0.1…15 s, Reliable distinction between foam and liquid, Galvanic isolation of input circuits, output circuits and power supply

Quick Quote

MK91-12-R/24VDC
Turck

Level controller, 1-channel, , Responsivity: 0.2…100 k, Ω, Hysteresis: 10%, Output: 2 relays with 1 changeover contact, Electronic switching of electrodes, Switch-on/off delay 0…20 s, separately adjustable, Reliable distinction between foam and liquid, Galvanic isolation of input circuits, output circuits and power supply

Quick Quote

ItemManufacturerPriceStockDelivery
MS27-R

MS27-R

Zero-speed Monitor, 1-channel, , Rotation underspeed monitoring, Monitoring range: 25 mHz… 166 Hz (1.5…10 000, min-1, ), Removable terminal blocks, Start-up bypass, activatable, Adjustable switch-off delay, Two sealed relays with hard gold contact (1 x limit value, 1 x alarm), Complete galvanic isolation, Input reverse-polarity protected

Turck

$797.30

Quick Quote

MK91-R11/24VDC

MK91-R11/24VDC

Level controller, 1-channel, , Switching point at 40 k, Ω, Hysteresis approx. 5%, Output: Relay with 1 changeover contact, Complete galvanic isolation, Input reverse-polarity protected

Turck

$177.60

Quick Quote

MS24-112-R

MS24-112-R

Rotation speed monitor, 1-channel, , Rotation speed monitoring for overspeed or underspeed, Monitoring range: 25 mHz…50 Hz (1.5…3 000), min-1, ), Line monitored for wire-break/short-circuit, Removable terminal blocks, One relay output as changeover contact, Start-up bypass, activatable, Complete galvanic isolation, Input reverse-polarity protected

Turck

$922.40

Quick Quote

MK91-121-R/24VDC

MK91-121-R/24VDC

Level controller, 1-channel, , Responsivity: 0.2…100 k, Ω, Hysteresis: 10%, Output: 2 relays with 1 changeover contact, Electronic switching of electrodes, Switch-on/off delay 0…20 s, separately adjustable, Reliable distinction between foam and liquid, Galvanic isolation of input circuits, output circuits and power supply

Turck

$487.00

Quick Quote

IMS-AI-DLI-22-DLI/L

IMS-AI-DLI-22-DLI/L

Analog signal isolator, 2-channel, , Input circuits: 0/4…20 mA, Output circuits: 0/4…20 mA, Accuracy, , Complete galvanic isolation, Input reverse-polarity protected, 6.2 mm width, UL: Class1, Div 2, Group A, B, C, D; GOST

Turck

Quick Quote

MS23-R

MS23-R

Rotation direction discriminator, 1-channel, , Rotation direction discriminator, Adjustable switch-off delay, Removable terminal blocks, Complete galvanic isolation, Input reverse-polarity protected

Turck

Quick Quote

IMS-TI-PT100/24V

IMS-TI-PT100/24V

Temperature measuring amplifier, 1-channel, , Connection of temperature probe Pt100, Output circuit: 0/4…20 mA or 0…10 V, Accuracy, , Complete galvanic isolation, Input reverse-polarity protected, 6.2 mm width, UL: Class1, Div2, Group A, B, C, D; GOST

Turck

Quick Quote

MK91-12-R/230VAC

MK91-12-R/230VAC

Level controller, 1-channel, , Responsivity: 0.2…100 k, Ω, Hysteresis: 10%, Output: 2 relays with 1 changeover contact, Electronic switching of electrodes, Switch-on/off delay 0…20 s, separately adjustable, Reliable distinction between foam and liquid, Galvanic isolation of input circuits, output circuits and power supply

Turck

Quick Quote

MS91-12-R

MS91-12-R

Level controller, 1-channel, , Output: 2 relays with changeover contact, Responsivity: 0.2…100 k, Ω, , Removable terminal blocks, Switching of electrodes via auxiliary relay, Switch-on/off delay adjustable 0.1…15 s, Reliable distinction between foam and liquid, Galvanic isolation of input circuits, output circuits and power supply

Turck

Quick Quote

MK91-12-R/24VDC

MK91-12-R/24VDC

Level controller, 1-channel, , Responsivity: 0.2…100 k, Ω, Hysteresis: 10%, Output: 2 relays with 1 changeover contact, Electronic switching of electrodes, Switch-on/off delay 0…20 s, separately adjustable, Reliable distinction between foam and liquid, Galvanic isolation of input circuits, output circuits and power supply

Turck

Quick Quote

Signal Conditioners

General Guide & Overview

Signal conditioning is an essential part of the data acquisition process, as it prepares analog signals from sensors for further processing and conversion into digital form. It manipulates the signal to enhance its quality and ensure accurate measurements. Signal conditioners are used in various industries and applications, such as temperature and vibration measurements. They are crucial in enhancing sensor performance and ensuring precise data in industrial applications. This guide will provide a general overview of signal conditioners and their role in the measurement process.

Introduction to Signal Conditioners

Signal conditioners are electronic circuits that manipulate signals to prepare them for the next stage of processing. They play a crucial role in enhancing the accuracy and reliability of sensor measurements by addressing the specific requirements of different sensors.

Sensor conditioning is necessary for various types of sensors, including thermocouples, RTDs, accelerometers, strain gauges, and load cells. These sensors have unique characteristics, such as different voltage levels, sensitivities, and output types, which need to be manipulated to ensure compatibility with data acquisition devices.

Types and Functions of Signal Conditioners

Signal conditioners are essential components in the field of sensor signal conditioning. They come in various types, each designed to cater to specific sensor requirements. These signal conditioners play a crucial role in enhancing the accuracy and reliability of sensor measurements.

Some common types of signal conditioners include:

Voltage and high-voltage signal conditioners

Current signal conditioners

IEPE signal conditioners

Charge signal conditioners

Strain gauge signal conditioners

2Load cell signal conditioners

Thermocouple signal conditioners

RTD signal conditioners

LVDT signal conditioners

Each type of signal conditioner provides various essential functions to ensure accurate and reliable measurements. These functions include:

Amplification: Signal conditioners amplify weak sensor signals to a level suitable for further processing.

Filtering: They filter out noise and interference, ensuring clean and precise signals.

Isolation: Signal conditioners provide isolation to protect the connected equipment from electrical interference.

Range selection: They allow for the selection of appropriate measuring ranges, ensuring optimal performance.

Signal conditioners can be standalone modules or integrated into larger signal conditioning systems. The choice depends on the specific application requirements and scalability. Additionally, programmable signal conditioners offer customization and flexibility in signal processing, allowing for tailored solutions.

Overall, signal conditioners are vital components in sensor signal conditioning systems, enabling accurate and reliable measurements across a wide range of industries and applications.

Signal conditioners play a crucial role in the measurement process, ensuring accurate and reliable data acquisition. They are responsible for preparing analog signals from sensors for conversion into digital form, taking into account the specific requirements and characteristics of each sensor.

Signal conditioning involves several key steps to enhance the quality and accuracy of the signals. Weak signals are amplified to ensure they can be accurately measured, while noise and interference are filtered out to eliminate any distortions. The signal conditioners also provide suitable connectors to facilitate seamless integration between sensors and data acquisition devices.

Load cells, a type of sensor commonly used in industrial applications, are a perfect example of how signal conditioners work. Load cells measure the force exerted by an object and generate an analog signal. The signal conditioner ensures that the load cell's analog signal is properly amplified, filtered, and calibrated before being converted into a digital signal that can be processed by data acquisition devices.

In summary, signal conditioners are essential for accurate and reliable measurements. They manipulate signals from sensors to enhance their quality, taking into account the specific requirements of each sensor. Whether it's load cells or other types of sensors, signal conditioners are crucial in ensuring precise and reliable data in various industrial applications.

FAQ

Signal conditioning is the process of manipulating analog signals from sensors to prepare them for further processing and conversion into digital form. It involves amplifying, filtering, and converting signals to ensure accuracy and compatibility with data acquisition devices.

Signal conditioners are used to enhance the accuracy and reliability of sensor measurements in various industries and applications, such as temperature and vibration measurements. They are essential in improving sensor performance and ensuring precise data in industrial settings.

Signal conditioners come in various types, including voltage, current, IEPE, charge, strain gauge, load cell, thermocouple, RTD, and LVDT signal conditioners. These conditioners provide functions such as amplification, filtering, isolation, and range selection, catering to the specific requirements of different sensors.

Signal conditioners work by manipulating analog signals from sensors through processes such as amplification, filtering, and isolation. They ensure compatibility with data acquisition devices by addressing the specific requirements and characteristics of each sensor, resulting in accurate and reliable data acquisition.

Load cells, which are sensors used for measuring force or weight, require signal conditioners to enhance their performance and ensure accurate measurements. Signal conditioners amplify and filter the electrical signals produced by load cells, making them compatible with data acquisition devices for precise data acquisition.