Schneider Electric XAPM14 is a die-cast empty control station from the XAP sub-range, designed without an opening. It is constructed from zinc alloy with a square shape. This control station offers a high degree of protection with ratings of IP69, IP65, and IP69K, suitable for flush mounting. The dimensions include a net height of 80 mm, a net depth of 77.3 mm, and a net width of 80 mm. It is capable of withstanding ambient air temperatures for storage ranging from -40 to +70 °C, with operational temperature limits also set between -40 °C and 70 °C.
Quick Quote
Schneider Electric XAPM3504 is a control station that falls under the XAP sub-range. This part is a die-cast empty control station featuring 4 cut-outs, with configurations for 1 vertical and 4 horizontal openings. It is constructed from a zinc alloy, ensuring durability, and has a rectangular shape. The XAPM3504 offers a high degree of protection with ratings of IP69, IP65, and IP69K, suitable for various environmental conditions. It is designed for flush mounting, with a mounting hole diameter of 22 mm. The dimensions include a net height of 175 mm, a net depth of 77 mm, and a net width of 80 mm. This control station can withstand ambient air temperatures for storage ranging from -40 to +70 degrees Celsius, with operational temperature limits also set between -40 and 70 degrees Celsius.
Quick Quote
Schneider Electric LC1F780F7 is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration and supports ring-lugs/bar connections. The contactor is rated for currents up to 1600A in AC-1 applications and 780A in 440Vac AC-3 scenarios. The control voltage (AC) specifications are 94-121Vac (110Vac nominal; 40-400Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. It has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV. Its rated active power ranges from 220kW at 220-230Vac in AC-3 applications up to 475kW at 660-690Vac in AC-3 applications, with additional ratings for various voltages in between. The mechanical durability of the LC1F780F7, at no load, is rated for 5,000,000 operations, and the rated voltage (AC) phase-to-phase is 1000 V.
Quick Quote
NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 240 VAC coil, NEMA 1
Quick Quote
Square D by Schneider Electric HJL26045 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HJL sub-range, featuring a PowerPact H-Frame 150 TMD 2P 45A 600Vac/250Vdc 25kA design with lugs on both load and line sides for connections. This 2-pole (2P) circuit breaker offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. It has a rated current of 45A, with a rated insulation voltage (Ui) of 750 V, and operates at rated voltages of 600Vac 600Y/347Vac for AC and 250Vdc for DC. The unit is designed for individual mounting on a plate, with dimensions of 163 mm in height, 104 mm in width, and 86 mm in depth. It provides an IP40 degree of protection and features a manual toggle operating mode. Protection settings include over-current fixed at 45A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 850A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 45 AT, with a frame current rating of 150 AF. Its short circuit breaking rating varies with voltage, offering 100kA at 240Vac, 65kA at 480Vac and 480Y/277Vac, 25kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all in accordance with UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display, and it falls under utilisation category A.
Quick Quote
Square D by Schneider Electric JDL36200SO is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT JDL sub-range, featuring a factory-installed 24Vdc shunt trip release coil. This PowerPacT J-Frame device is designed with 250 TMD, 3 poles (3P), and a rated current of 200A. It operates at a rated insulation voltage (Ui) of 750 V, with AC rated voltages of 600Vac and 600Y/347Vac, and a DC rated voltage of 250Vdc. The breaker offers thermal (overload) and magnetic (short-circuit) protection functions, with a net height of 191 mm, width of 105 mm, and depth of 127 mm. It supports a mounting mode of individual unit mount on plate, has a degree of protection of IP40, and operates manually via a toggle. Protection settings include over-current fixed at 200A and short-circuit pickup current adjustable between 1000A and 2000A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 200 AT, with a frame current rating of 250 AF. Its short circuit breaking rating varies by voltage, including 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (adjustable) without a display, and it falls under utilisation category A. Connections are made via lugs on both load and line sides.
Quick Quote
Square D by Schneider Electric JLL26175 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT JLL sub-range, featuring a PowerPact J-Frame 250 TMD 2P 175A 600Vac 50kA design with lugs 80% rated for connection on both load and line sides. It is a 2-pole (2P) device offering thermal protection for overload and magnetic protection for short-circuit scenarios. The rated current is 175A, with a rated insulation voltage (Ui) of 750 V and an AC rated voltage of 600Vac 600Y/347Vac. This unit is designed for individual unit mount on plate, with dimensions of 191 mm in height, 105 mm in width, and 127 mm in depth. It operates with a toggle (manual) mechanism, has a degree of protection of IP40, and features over-current protection fixed at 175A and short-circuit pickup current adjustable between 875A and 1750A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 175 AT, and the frame current rating is 250 AF. It has a short circuit breaking rating of 125kA at 240Vac, 100kA at 480Vac and 480Y/277Vac, 50kA at 600Vac and 600Y/347Vac, 20kA at 250Vdc, and 50kA at 500Vdc, all under UL489. The trip unit type is thermal-magnetic (adjustable) with no display, and it falls under utilisation category A.
Quick Quote
Square D by Schneider Electric JLL26200 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT JLL sub-range, featuring a PowerPact J-Frame 250 TMD 2P 200A 600Vac 50kA design with lugs 80% rated for connection on both load and line sides. It is a 2-pole (2P) device offering thermal protection for overload and magnetic protection for short-circuit scenarios. The rated current is 200A, with a rated insulation voltage (Ui) of 750 V and an AC rated voltage of 600Vac 600Y/347Vac. This unit is designed for individual unit mount on plate, with a net height of 191 mm, width of 105 mm, and depth of 127 mm. It operates with a toggle (manual) mode, has a degree of protection of IP40, and offers over-current protection fixed at 200A and short-circuit pickup current adjustable between 1000A and 2000A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 200 AT, and the frame current rating is 250 AF. It has a short circuit breaking rating of 125kA at 240Vac, 100kA at 480Vac and 480Y/277Vac, 50kA at 600Vac and 600Y/347Vac, 20kA at 250Vdc, and 50kA at 500Vdc, all under UL489. The trip unit type is thermal-magnetic (adjustable) with no display, and it falls under utilisation category A.
Quick Quote
Square D by Schneider Electric HDL36030T is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HDL sub-range. It features a removable/interchangeable trip unit PowerPact H-Frame 150 TMD with 3 poles (3P) and a rated current of 30A. This MCCB is designed for 600Vac/250Vdc with a 14kA breaking capacity and includes lugs on both load and line sides for connection. It offers thermal protection for overload and magnetic protection for short-circuit situations. The rated insulation voltage (Ui) is 750 V, with a rated voltage (AC) of 600Vac 600Y/347Vac and a rated voltage (DC) of 250Vdc. The unit is designed for individual mount on plate, with a net height of 163 mm, width of 104 mm, and depth of 86 mm. It has an IP40 degree of protection and operates with a toggle (manual) mechanism. Protection settings are fixed, with over-current at 30A, short-circuit hold current at 350A, and short-circuit trip current at 750A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 30 AT, and the frame current rating is 150 AF. The short circuit breaking rating varies with voltage, up to 25kA at 240Vac and 20kA at 250Vdc, according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display, and it falls under utilisation category A.
Quick Quote
Schneider Electric ATS48D88Y is a soft starter from the Altistart 48 series, designed with a 3-controlled phases Torque Control System (TCS) and an optional FIPIO protocol for asynchronous motor bypass. It operates on a supply voltage of 177-759Vac (208Vac / 240Vac / 480Vac / 690Vac nom.; 50/60Hz) and has dimensions of H290mm x W190mm x D235mm. The connection type is screw connections with a degree of protection rated at IP00. It has a rated current of 88A for standard applications, 75A for severe applications, and a factory setting current of 77A. This soft starter is suitable for wall mounting and supports communication protocols such as Modbus, Modbus TCP, DeviceNet, and PROFIBUS DP, over a 3-phase network. It operates efficiently within an ambient air temperature range of +14...+104°F / -10...+40 °C without derating and can handle up to +104...+140°F / +40...+60 °C with current derating of 2.2% per °C. The ATS48D88Y features 1 analog output (0-20mA / 4-20mA), multiple digital inputs and outputs for comprehensive control, and is designed for ambient air temperatures for storage between -13...158°F / -25...70 °C. Its rated active power varies by application and voltage, supporting a wide range of industrial needs, with power dissipation/losses of 2537 W for standard applications and 2073 W for severe applications.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
XAPM14 Schneider Electric XAPM14 is a die-cast empty control station from the XAP sub-range, designed without an opening. It is constructed from zinc alloy with a square shape. This control station offers a high degree of protection with ratings of IP69, IP65, and IP69K, suitable for flush mounting. The dimensions include a net height of 80 mm, a net depth of 77.3 mm, and a net width of 80 mm. It is capable of withstanding ambient air temperatures for storage ranging from -40 to +70 °C, with operational temperature limits also set between -40 °C and 70 °C. | Schneider Electric | $136.00 | Quick Quote | ||
XAPM3504 Schneider Electric XAPM3504 is a control station that falls under the XAP sub-range. This part is a die-cast empty control station featuring 4 cut-outs, with configurations for 1 vertical and 4 horizontal openings. It is constructed from a zinc alloy, ensuring durability, and has a rectangular shape. The XAPM3504 offers a high degree of protection with ratings of IP69, IP65, and IP69K, suitable for various environmental conditions. It is designed for flush mounting, with a mounting hole diameter of 22 mm. The dimensions include a net height of 175 mm, a net depth of 77 mm, and a net width of 80 mm. This control station can withstand ambient air temperatures for storage ranging from -40 to +70 degrees Celsius, with operational temperature limits also set between -40 and 70 degrees Celsius. | Schneider Electric | $218.00 | Quick Quote | ||
LC1F780F7 Schneider Electric LC1F780F7 is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration and supports ring-lugs/bar connections. The contactor is rated for currents up to 1600A in AC-1 applications and 780A in 440Vac AC-3 scenarios. The control voltage (AC) specifications are 94-121Vac (110Vac nominal; 40-400Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. It has no Normally Open (NO) or Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV. Its rated active power ranges from 220kW at 220-230Vac in AC-3 applications up to 475kW at 660-690Vac in AC-3 applications, with additional ratings for various voltages in between. The mechanical durability of the LC1F780F7, at no load, is rated for 5,000,000 operations, and the rated voltage (AC) phase-to-phase is 1000 V. | Schneider Electric | $7,788.00 | Quick Quote | ||
8502SEG2V03 NEMA Contactor, Type S, nonreversing, Size 3, 90A, 50 HP at 575 VAC, 3 phase, up to 100 kA, 3 pole, 240 VAC coil, NEMA 1 | Schneider Electric | $1,715.00 | Quick Quote | ||
HJL26045 Square D by Schneider Electric HJL26045 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HJL sub-range, featuring a PowerPact H-Frame 150 TMD 2P 45A 600Vac/250Vdc 25kA design with lugs on both load and line sides for connections. This 2-pole (2P) circuit breaker offers thermal protection for overload scenarios and magnetic protection for short-circuit conditions. It has a rated current of 45A, with a rated insulation voltage (Ui) of 750 V, and operates at rated voltages of 600Vac 600Y/347Vac for AC and 250Vdc for DC. The unit is designed for individual mounting on a plate, with dimensions of 163 mm in height, 104 mm in width, and 86 mm in depth. It provides an IP40 degree of protection and features a manual toggle operating mode. Protection settings include over-current fixed at 45A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 850A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 45 AT, with a frame current rating of 150 AF. Its short circuit breaking rating varies with voltage, offering 100kA at 240Vac, 65kA at 480Vac and 480Y/277Vac, 25kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all in accordance with UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display, and it falls under utilisation category A. | Schneider Electric | $1,559.00 | Quick Quote | ||
JDL36200SO Square D by Schneider Electric JDL36200SO is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT JDL sub-range, featuring a factory-installed 24Vdc shunt trip release coil. This PowerPacT J-Frame device is designed with 250 TMD, 3 poles (3P), and a rated current of 200A. It operates at a rated insulation voltage (Ui) of 750 V, with AC rated voltages of 600Vac and 600Y/347Vac, and a DC rated voltage of 250Vdc. The breaker offers thermal (overload) and magnetic (short-circuit) protection functions, with a net height of 191 mm, width of 105 mm, and depth of 127 mm. It supports a mounting mode of individual unit mount on plate, has a degree of protection of IP40, and operates manually via a toggle. Protection settings include over-current fixed at 200A and short-circuit pickup current adjustable between 1000A and 2000A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 200 AT, with a frame current rating of 250 AF. Its short circuit breaking rating varies by voltage, including 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (adjustable) without a display, and it falls under utilisation category A. Connections are made via lugs on both load and line sides. | Schneider Electric | $3,447.00 | Quick Quote | ||
JLL26175 Square D by Schneider Electric JLL26175 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT JLL sub-range, featuring a PowerPact J-Frame 250 TMD 2P 175A 600Vac 50kA design with lugs 80% rated for connection on both load and line sides. It is a 2-pole (2P) device offering thermal protection for overload and magnetic protection for short-circuit scenarios. The rated current is 175A, with a rated insulation voltage (Ui) of 750 V and an AC rated voltage of 600Vac 600Y/347Vac. This unit is designed for individual unit mount on plate, with dimensions of 191 mm in height, 105 mm in width, and 127 mm in depth. It operates with a toggle (manual) mechanism, has a degree of protection of IP40, and features over-current protection fixed at 175A and short-circuit pickup current adjustable between 875A and 1750A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 175 AT, and the frame current rating is 250 AF. It has a short circuit breaking rating of 125kA at 240Vac, 100kA at 480Vac and 480Y/277Vac, 50kA at 600Vac and 600Y/347Vac, 20kA at 250Vdc, and 50kA at 500Vdc, all under UL489. The trip unit type is thermal-magnetic (adjustable) with no display, and it falls under utilisation category A. | Schneider Electric | $5,811.00 | Quick Quote | ||
JLL26200 Square D by Schneider Electric JLL26200 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT JLL sub-range, featuring a PowerPact J-Frame 250 TMD 2P 200A 600Vac 50kA design with lugs 80% rated for connection on both load and line sides. It is a 2-pole (2P) device offering thermal protection for overload and magnetic protection for short-circuit scenarios. The rated current is 200A, with a rated insulation voltage (Ui) of 750 V and an AC rated voltage of 600Vac 600Y/347Vac. This unit is designed for individual unit mount on plate, with a net height of 191 mm, width of 105 mm, and depth of 127 mm. It operates with a toggle (manual) mode, has a degree of protection of IP40, and offers over-current protection fixed at 200A and short-circuit pickup current adjustable between 1000A and 2000A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 200 AT, and the frame current rating is 250 AF. It has a short circuit breaking rating of 125kA at 240Vac, 100kA at 480Vac and 480Y/277Vac, 50kA at 600Vac and 600Y/347Vac, 20kA at 250Vdc, and 50kA at 500Vdc, all under UL489. The trip unit type is thermal-magnetic (adjustable) with no display, and it falls under utilisation category A. | Schneider Electric | $5,811.00 | Quick Quote | ||
HDL36030T Square D by Schneider Electric HDL36030T is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT HDL sub-range. It features a removable/interchangeable trip unit PowerPact H-Frame 150 TMD with 3 poles (3P) and a rated current of 30A. This MCCB is designed for 600Vac/250Vdc with a 14kA breaking capacity and includes lugs on both load and line sides for connection. It offers thermal protection for overload and magnetic protection for short-circuit situations. The rated insulation voltage (Ui) is 750 V, with a rated voltage (AC) of 600Vac 600Y/347Vac and a rated voltage (DC) of 250Vdc. The unit is designed for individual mount on plate, with a net height of 163 mm, width of 104 mm, and depth of 86 mm. It has an IP40 degree of protection and operates with a toggle (manual) mechanism. Protection settings are fixed, with over-current at 30A, short-circuit hold current at 350A, and short-circuit trip current at 750A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 30 AT, and the frame current rating is 150 AF. The short circuit breaking rating varies with voltage, up to 25kA at 240Vac and 20kA at 250Vdc, according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display, and it falls under utilisation category A. | Schneider Electric | $1,632.00 | Quick Quote | ||
ATS48D88Y Schneider Electric ATS48D88Y is a soft starter from the Altistart 48 series, designed with a 3-controlled phases Torque Control System (TCS) and an optional FIPIO protocol for asynchronous motor bypass. It operates on a supply voltage of 177-759Vac (208Vac / 240Vac / 480Vac / 690Vac nom.; 50/60Hz) and has dimensions of H290mm x W190mm x D235mm. The connection type is screw connections with a degree of protection rated at IP00. It has a rated current of 88A for standard applications, 75A for severe applications, and a factory setting current of 77A. This soft starter is suitable for wall mounting and supports communication protocols such as Modbus, Modbus TCP, DeviceNet, and PROFIBUS DP, over a 3-phase network. It operates efficiently within an ambient air temperature range of +14...+104°F / -10...+40 °C without derating and can handle up to +104...+140°F / +40...+60 °C with current derating of 2.2% per °C. The ATS48D88Y features 1 analog output (0-20mA / 4-20mA), multiple digital inputs and outputs for comprehensive control, and is designed for ambient air temperatures for storage between -13...158°F / -25...70 °C. Its rated active power varies by application and voltage, supporting a wide range of industrial needs, with power dissipation/losses of 2537 W for standard applications and 2073 W for severe applications. | Schneider Electric | $1,575.00 | Quick Quote |