Schneider Electric LP5K0901JW3 is a pre-assembled reversing magnetic contactor within the K sub-range, featuring a mechanical interlock design and screw connections. It comprises 2 x 3-poles (2x3P; 2x3NO) with a rated current of 20A (AC-1) and 9A (440Vac; AC-3). This contactor offers a degree of protection of IP20 and operates with a control voltage (DC) of 8.4-15.6Vdc (12Vdc nom.; 0.7...1.3 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 0 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with contacts type of 1NC (contactor A) + 1NC (contactor B). The rated active power (kW) spans 2.2kW (220-230Vac; AC-3) to 4kW across various voltages up to 660-690Vac (AC-3). Mechanical durability is rated at 5,000,000 operations at no load, with a power consumption of 1.8 W and a rated voltage (AC) - phase-to-phase of 690 V.
Quick Quote
Schneider Electric LP4K06105EW3 is a magnetic contactor within the K sub-range, featuring solder pins connections and a 3-pole (3P; 3NO) configuration. It has a rated current of 6A at 440Vac under AC-3 utilization category and offers a degree of protection of IP20. The control voltage (DC) ranges from 33.6 to 62.4Vdc, with a nominal value of 48Vdc, equivalent to 0.7 to 1.3 times the control voltage (Uc). This contactor is designed to operate at a rated operating voltage (Ue) of up to 690 V and includes 1 Normally Open (NO) auxiliary contact. It supports rated active power loads of 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. The unit does not have Normally Closed (NC) auxiliary contacts. It is built for mechanical durability, capable of 30 million operations at no load, and has a power consumption of 1.8 W.
Quick Quote
Schneider Electric LP4K06015BW3 is a magnetic contactor within the K sub-range, featuring solder pins connections and a 3-pole (3P; 3NO) configuration. It has a rated current of 6A at 440Vac under AC-3 utilization category and offers a degree of protection rated at IP20. The control voltage (DC) ranges from 16.8-31.2Vdc, with a nominal value of 24Vdc (0.7...1.3 x Uc). Its rated operating voltage (Ue) reaches up to 690 V. This model includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated active power varies with voltage, providing 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3. It boasts a mechanical durability of 30,000,000 operations at no load and has a power consumption of 1.8 W. The rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LP2K09004GD is a pre-assembled reversing magnetic contactor within the K sub-range, featuring a mechanical interlock design. It is equipped with screw connections and has 2 x 4-poles (2x4NO) configuration. The rated current for this contactor is 20A under AC-1 conditions and 110A (Irms AC), with a degree of protection classified as IP20. The control voltage (DC) specifications are 100-143Vdc, with a nominal value of 125Vdc, operating within 0.8 to 1.15 times the control voltage (Uc). It is designed to operate at a rated operating voltage (Ue) of 690 V and has both normally open (NO) and normally closed (NC) auxiliary contacts listed as 0. The mechanical durability of the LP2K09004GD, at no load, is rated at 5,000,000 operations, and it supports a rated voltage (AC) for phase-to-phase connections at 690 V.
Quick Quote
Schneider Electric LP1K1201JD is a magnetic contactor within the K sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 20A under AC-1 conditions and 12A at 440Vac under AC-3 conditions. The contactor's net width is 45 mm and it offers a degree of protection rated at IP20. The control voltage (DC) specifications are 9.6-13.8Vdc, with a nominal 12Vdc, corresponding to 0.8...1.15 times the control voltage (Uc). It operates at a rated operating voltage (Ue) of up to 690 V and includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated active power varies with voltage, being 3kW at 220-230Vac, 5.5kW at 380-415Vac and 440Vac, and 4kW at 500Vac and 660-690Vac, all under AC-3 conditions. Its mechanical durability is rated for 10,000,000 operations at no load, and the rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC2D40A3G7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) term. power connection by Everlink mechanical interlock. It has spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 96-132Vac (120Vac nom.; 50Hz; 0.8...1.1 x Uc) and 102-132Vac (120Vac nom.; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The contactor supports a rated active power (kW) of 11kW (220-230Vac; AC-3), 18.5kW (380-400Vac; AC-3), 22kW (415Vac; AC-3), 22kW (440Vac; AC-3), 22kW (500Vac; AC-3), and 30kW (660-690Vac; AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor and has a rated power (HP) of 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 5HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 10HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 10HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 30HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - Phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC2D40A3F7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal power connections with an Everlink mechanical interlock. It utilizes spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). The contactor is designed with a degree of protection of IP20 and operates with a control voltage (AC) of 88-121Vac (110Vac nominal; 50Hz; 0.8...1.1 x Uc) and 93.5-121Vac (110Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 11kW at 220-230Vac to 30kW at 660-690Vac, all under AC-3 classification. Additionally, it features 1NO+1NC instantaneous auxiliary contacts per contactor and supports rated power (HP) for various voltages and phases, including 3HP at 115Vac single-phase and up to 30HP at 575-600Vac 3-phase, under UL/CSA standards. The rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC2D32BDV is a pre-assembled reversing magnetic contactor from the Deca sub-range, designed with an electrical/mechanical interlock and a set of reversing power busbars. It features screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 50A (AC-1) and 32A (440Vac; AC-3). The contactor is protected by an IP20 degree of protection and operates with a control voltage (DC) of 18-30Vdc (24Vdc nom.; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it has a rated active power of 7.5kW to 18.5kW across various AC-3 voltages. Additionally, it features 2 Normally Closed (NC) auxiliary contacts and 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 2HP to 25HP across various voltages and phases, with a phase-to-phase rated voltage (AC) of 690 V.
Quick Quote
Schneider Electric LC2D25JD is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and screw connections. It is designed with 2 x 3-poles (2x3P; 2x3NO) and has a rated current of 40A (AC-1) and 25A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (DC) of 9-15Vdc (12Vdc nom.; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous aux. contacts per contactor. The rated impulse voltage (Uimp) is 6 kV. It supports rated active power (kW) of 5.5kW (220-230Vac; AC-3), 11kW (380-400Vac; AC-3) up to 15kW (660-690Vac; AC-3), and rated power (HP) for various voltages and phases, including 2HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) and up to 20HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - Phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC2D183BL is a pre-assembled reversing magnetic contactor from the Deca sub-range, designed with a low-consumption coil that consumes less than 2.4W and features a mechanical interlock. It offers spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 32A for AC-1 and 18A for 440Vac in AC-3 applications. The contactor is protected by an IP20 enclosure and operates with a control voltage (DC) range of 19.2-30Vdc, nominally at 24Vdc. It supports a rated operating voltage (Ue) up to 690 V and includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power spans from 4kW at 220-230Vac to 10kW at 660-690Vac in AC-3, complemented by 2 Normally Closed (NC) auxiliary contacts and 1NO+1NC instantaneous auxiliary contacts per contactor. Its rated power in horsepower (HP) varies from 1HP at 115Vac in single-phase to 15HP at 575-600Vac in three-phase applications, under UL/CSA standards. The phase-to-phase rated voltage (AC) is 690 V, ensuring compatibility with a wide range of industrial applications.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LP5K0901JW3 Schneider Electric LP5K0901JW3 is a pre-assembled reversing magnetic contactor within the K sub-range, featuring a mechanical interlock design and screw connections. It comprises 2 x 3-poles (2x3P; 2x3NO) with a rated current of 20A (AC-1) and 9A (440Vac; AC-3). This contactor offers a degree of protection of IP20 and operates with a control voltage (DC) of 8.4-15.6Vdc (12Vdc nom.; 0.7...1.3 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 0 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with contacts type of 1NC (contactor A) + 1NC (contactor B). The rated active power (kW) spans 2.2kW (220-230Vac; AC-3) to 4kW across various voltages up to 660-690Vac (AC-3). Mechanical durability is rated at 5,000,000 operations at no load, with a power consumption of 1.8 W and a rated voltage (AC) - phase-to-phase of 690 V. | Schneider Electric | Quick Quote | |||
LP4K06105EW3 Schneider Electric LP4K06105EW3 is a magnetic contactor within the K sub-range, featuring solder pins connections and a 3-pole (3P; 3NO) configuration. It has a rated current of 6A at 440Vac under AC-3 utilization category and offers a degree of protection of IP20. The control voltage (DC) ranges from 33.6 to 62.4Vdc, with a nominal value of 48Vdc, equivalent to 0.7 to 1.3 times the control voltage (Uc). This contactor is designed to operate at a rated operating voltage (Ue) of up to 690 V and includes 1 Normally Open (NO) auxiliary contact. It supports rated active power loads of 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3 conditions. The unit does not have Normally Closed (NC) auxiliary contacts. It is built for mechanical durability, capable of 30 million operations at no load, and has a power consumption of 1.8 W. | Schneider Electric | Quick Quote | |||
LP4K06015BW3 Schneider Electric LP4K06015BW3 is a magnetic contactor within the K sub-range, featuring solder pins connections and a 3-pole (3P; 3NO) configuration. It has a rated current of 6A at 440Vac under AC-3 utilization category and offers a degree of protection rated at IP20. The control voltage (DC) ranges from 16.8-31.2Vdc, with a nominal value of 24Vdc (0.7...1.3 x Uc). Its rated operating voltage (Ue) reaches up to 690 V. This model includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated active power varies with voltage, providing 1.5kW at 220-230Vac, 2.2kW at 380-415Vac, and 3kW at 440Vac, 500Vac, and 660-690Vac, all under AC-3. It boasts a mechanical durability of 30,000,000 operations at no load and has a power consumption of 1.8 W. The rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LP2K09004GD Schneider Electric LP2K09004GD is a pre-assembled reversing magnetic contactor within the K sub-range, featuring a mechanical interlock design. It is equipped with screw connections and has 2 x 4-poles (2x4NO) configuration. The rated current for this contactor is 20A under AC-1 conditions and 110A (Irms AC), with a degree of protection classified as IP20. The control voltage (DC) specifications are 100-143Vdc, with a nominal value of 125Vdc, operating within 0.8 to 1.15 times the control voltage (Uc). It is designed to operate at a rated operating voltage (Ue) of 690 V and has both normally open (NO) and normally closed (NC) auxiliary contacts listed as 0. The mechanical durability of the LP2K09004GD, at no load, is rated at 5,000,000 operations, and it supports a rated voltage (AC) for phase-to-phase connections at 690 V. | Schneider Electric | Quick Quote | |||
LP1K1201JD Schneider Electric LP1K1201JD is a magnetic contactor within the K sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 20A under AC-1 conditions and 12A at 440Vac under AC-3 conditions. The contactor's net width is 45 mm and it offers a degree of protection rated at IP20. The control voltage (DC) specifications are 9.6-13.8Vdc, with a nominal 12Vdc, corresponding to 0.8...1.15 times the control voltage (Uc). It operates at a rated operating voltage (Ue) of up to 690 V and includes 0 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated active power varies with voltage, being 3kW at 220-230Vac, 5.5kW at 380-415Vac and 440Vac, and 4kW at 500Vac and 660-690Vac, all under AC-3 conditions. Its mechanical durability is rated for 10,000,000 operations at no load, and the rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC2D40A3G7 Schneider Electric LC2D40A3G7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) term. power connection by Everlink mechanical interlock. It has spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 96-132Vac (120Vac nom.; 50Hz; 0.8...1.1 x Uc) and 102-132Vac (120Vac nom.; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. The contactor supports a rated active power (kW) of 11kW (220-230Vac; AC-3), 18.5kW (380-400Vac; AC-3), 22kW (415Vac; AC-3), 22kW (440Vac; AC-3), 22kW (500Vac; AC-3), and 30kW (660-690Vac; AC-3). It also features 1NO+1NC instantaneous auxiliary contacts per contactor and has a rated power (HP) of 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA), 5HP (230-240Vac; single-phase; 50Hz/60Hz; UL/CSA), 10HP (200-208Vac; 3-phase; 50Hz/60Hz; UL/CSA), 10HP (230-240Vac; 3-phase; 50Hz/60Hz; UL/CSA), 30HP (460-480Vac; 3-phase; 50Hz/60Hz; UL/CSA), and 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - Phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC2D40A3F7 Schneider Electric LC2D40A3F7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal power connections with an Everlink mechanical interlock. It utilizes spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). The contactor is designed with a degree of protection of IP20 and operates with a control voltage (AC) of 88-121Vac (110Vac nominal; 50Hz; 0.8...1.1 x Uc) and 93.5-121Vac (110Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 11kW at 220-230Vac to 30kW at 660-690Vac, all under AC-3 classification. Additionally, it features 1NO+1NC instantaneous auxiliary contacts per contactor and supports rated power (HP) for various voltages and phases, including 3HP at 115Vac single-phase and up to 30HP at 575-600Vac 3-phase, under UL/CSA standards. The rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC2D32BDV Schneider Electric LC2D32BDV is a pre-assembled reversing magnetic contactor from the Deca sub-range, designed with an electrical/mechanical interlock and a set of reversing power busbars. It features screw connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 50A (AC-1) and 32A (440Vac; AC-3). The contactor is protected by an IP20 degree of protection and operates with a control voltage (DC) of 18-30Vdc (24Vdc nom.; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and it has a rated active power of 7.5kW to 18.5kW across various AC-3 voltages. Additionally, it features 2 Normally Closed (NC) auxiliary contacts and 1NO+1NC instantaneous auxiliary contacts per contactor. The rated power (HP) ranges from 2HP to 25HP across various voltages and phases, with a phase-to-phase rated voltage (AC) of 690 V. | Schneider Electric | Quick Quote | |||
LC2D25JD Schneider Electric LC2D25JD is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock and screw connections. It is designed with 2 x 3-poles (2x3P; 2x3NO) and has a rated current of 40A (AC-1) and 25A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (DC) of 9-15Vdc (12Vdc nom.; 0.75...1.25 x Uc). Its rated operating voltage (Ue) is up to 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts, with a contacts type of 1NO+1NC instantaneous aux. contacts per contactor. The rated impulse voltage (Uimp) is 6 kV. It supports rated active power (kW) of 5.5kW (220-230Vac; AC-3), 11kW (380-400Vac; AC-3) up to 15kW (660-690Vac; AC-3), and rated power (HP) for various voltages and phases, including 2HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) and up to 20HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The rated voltage (AC) - Phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC2D183BL Schneider Electric LC2D183BL is a pre-assembled reversing magnetic contactor from the Deca sub-range, designed with a low-consumption coil that consumes less than 2.4W and features a mechanical interlock. It offers spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 32A for AC-1 and 18A for 440Vac in AC-3 applications. The contactor is protected by an IP20 enclosure and operates with a control voltage (DC) range of 19.2-30Vdc, nominally at 24Vdc. It supports a rated operating voltage (Ue) up to 690 V and includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power spans from 4kW at 220-230Vac to 10kW at 660-690Vac in AC-3, complemented by 2 Normally Closed (NC) auxiliary contacts and 1NO+1NC instantaneous auxiliary contacts per contactor. Its rated power in horsepower (HP) varies from 1HP at 115Vac in single-phase to 15HP at 575-600Vac in three-phase applications, under UL/CSA standards. The phase-to-phase rated voltage (AC) is 690 V, ensuring compatibility with a wide range of industrial applications. | Schneider Electric | Quick Quote |