Schneider Electric LC2V320V7 is a pre-assembled reversing vacuum contactor within the V sub-range. It features a mechanical interlock design and offers ring-lugs/bar connections for installation. This contactor is equipped with 2 x 3-poles (2x3P; 2x3NO) and supports a rated current of 320A for both AC-1 and AC-3 (440Vac) applications. The control voltage (AC) ranges from 304-456Vac (380-415Vac nominal; 50Hz/60Hz; 0.8...1.1 x Uc), with a rated operating voltage (Ue) of 1500 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a rated impulse voltage (Uimp) of 8 kV. The rated active power (kW) varies from 90kW at 230Vac to 400kW at 1000Vac in AC-3 configuration, and the rated voltage (AC) for phase-to-phase is 1500 V.
Quick Quote
Schneider Electric LC2D65A3FE7 is a pre-assembled reversing magnetic contactor from the Deca sub-range. It features an EverLink(TM) term. power connection with an Everlink mechanical interlock and spring connections. This contactor has 2 x 3-poles (2x3P; 2x3NO) and is rated for 80A (AC-1) and 65A (440Vac; AC-3). It offers a degree of protection of IP20 and operates with a control voltage (AC) of 92-126Vac (115Vac nom.; 50Hz; 0.8...1.1 x Uc) and 98-126Vac (115Vac nom.; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. Its rated active power (kW) spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac, all in AC-3 category. The contactor also features 1NO+1NC instantaneous auxiliary contacts per contactor. Its rated power (HP) ranges from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC2D65A3D7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal power connections with an Everlink mechanical interlock. It utilizes spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 65A (440Vac; AC-3). The contactor is designed with a degree of protection of IP20 and operates with a control voltage (AC) of 33.6-46.2Vac (42Vac nominal; 50Hz; 0.8...1.1 x Uc) and 35.7-46.2Vac (42Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac (AC-3), and it also features 2 Normally Closed (NC) auxiliary contacts, with contact types of 1NO+1NC instantaneous aux. contacts per contactor. The rated power (HP) ranges from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, with a phase-to-phase rated voltage (AC) of 690 V.
Quick Quote
Schneider Electric LC2D40E7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock design and screw connections. It comprises 2 x 3-poles (2x3P; 2x3NO) with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 38.4-52.8Vac (48Vac nominal; 50Hz; 0.8...1.1 x Uc) and 40.8-52.8Vac (48Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) ranges from 11kW at 220-230Vac to 30kW at 660-690Vac, all within AC-3 classification. Each contactor has 1NO+1NC instantaneous auxiliary contacts, and the rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1DT80AX7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for screw connections. This 4-pole (4P; 4NO) contactor is rated for 80A (AC-1) and is designed for DIN rail mounting. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage for AC ranges from 480-660Vac (600Vac nominal; 50Hz; 0.8...1.1 x Uc) to 510-660Vac (600Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+1NC instantaneous auxiliaries. The rated impulse voltage (Uimp) is 6 kV, and it has a mechanical durability of 6,000,000 operations at no load. The rated voltage (AC) phase-to-phase is 690 V.
Quick Quote
Schneider Electric LC1D80008T6 is a magnetic contactor from the Deca sub-range, designed with screw connections and four poles (4P; 2NO+2NC). It has a rated current of 125A (AC-1) and is suitable for DIN rail mounting. The net width of the contactor is 96 mm, and it offers a degree of protection of IP20. The control voltage (AC) ranges from 408-528Vac (480Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. This model does not include normally open (NO) or normally closed (NC) auxiliary contacts. It is capable of withstanding a rated impulse voltage (Uimp) of 8 kV and has a mechanical durability of 4 million operations at no load. The rated voltage (AC) for phase-to-phase connections is 1000 V.
Quick Quote
Schneider Electric LC1D65A6FC7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 80A for AC-1 and 65A for 440Vac in AC-3. It is designed for DIN rail mounting with a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 102-139Vac at 50Hz and 108-139Vac at 60Hz, with a nominal control voltage of 127Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65A6FC7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1D506FW is a magnetic contactor from the Deca sub-range designed with a wide-range coil (0.75-1.2 x Uc) for flexibility in control voltage, which ranges from 82.5-132Vdc (110Vdc nominal). It features ring-lugs connections for secure wiring and is equipped with 3 poles (3P; 3NO) suitable for various applications. The contactor supports a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and offers an IP20 degree of protection. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power capacity spans from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. Additionally, it has 1 Normally Closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac to 40HP at 575-600Vac, accommodating a wide range of motor applications. The mechanical durability of the LC1D506FW is rated at 15 million operations at no load, and its phase-to-phase rated voltage (AC) reaches up to 690 V.
Quick Quote
Schneider Electric LC1D40AMD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 60A for AC-1 and 40A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 165-275Vdc (220Vdc nominal; 0.75...1.25 x Uc), and the rated operating voltage (Ue) is up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor supports rated active power ranging from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3, and rated power (HP) from 3HP at 115Vac to 30HP at 575-600Vac, according to UL/CSA standards for single-phase and 3-phase connections. It boasts a mechanical durability of 6,000,000 operations and an electrical durability of 1,500,000 operations with load, with a phase-to-phase rated voltage (AC) of 690 V.
Quick Quote
Schneider Electric LC1D40A6FE7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminals and ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) of 92-126Vac (115Vac nominal; 50Hz; 0.8...1.1 x Uc) and 98-126Vac (115Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it comes with 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated current is 60A (AC-1) and 40A (440Vac; AC-3), with a rated impulse voltage (Uimp) of 6 kV. It supports rated active power of 11kW (220-230Vac; AC-3) up to 30kW (660-690Vac; AC-3) and rated power (HP) ranging from 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability is rated at 6,000,000 operations, and electrical durability (with load) at 1,500,000 operations. The rated voltage (AC) - phase-to-phase is 690 V.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LC2V320V7 Schneider Electric LC2V320V7 is a pre-assembled reversing vacuum contactor within the V sub-range. It features a mechanical interlock design and offers ring-lugs/bar connections for installation. This contactor is equipped with 2 x 3-poles (2x3P; 2x3NO) and supports a rated current of 320A for both AC-1 and AC-3 (440Vac) applications. The control voltage (AC) ranges from 304-456Vac (380-415Vac nominal; 50Hz/60Hz; 0.8...1.1 x Uc), with a rated operating voltage (Ue) of 1500 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with a rated impulse voltage (Uimp) of 8 kV. The rated active power (kW) varies from 90kW at 230Vac to 400kW at 1000Vac in AC-3 configuration, and the rated voltage (AC) for phase-to-phase is 1500 V. | Schneider Electric | Quick Quote | |||
LC2D65A3FE7 Schneider Electric LC2D65A3FE7 is a pre-assembled reversing magnetic contactor from the Deca sub-range. It features an EverLink(TM) term. power connection with an Everlink mechanical interlock and spring connections. This contactor has 2 x 3-poles (2x3P; 2x3NO) and is rated for 80A (AC-1) and 65A (440Vac; AC-3). It offers a degree of protection of IP20 and operates with a control voltage (AC) of 92-126Vac (115Vac nom.; 50Hz; 0.8...1.1 x Uc) and 98-126Vac (115Vac nom.; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV. Its rated active power (kW) spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac, all in AC-3 category. The contactor also features 1NO+1NC instantaneous auxiliary contacts per contactor. Its rated power (HP) ranges from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC2D65A3D7 Schneider Electric LC2D65A3D7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal power connections with an Everlink mechanical interlock. It utilizes spring connections and consists of 2 x 3-poles (2x3P; 2x3NO) with a rated current of 80A (AC-1) and 65A (440Vac; AC-3). The contactor is designed with a degree of protection of IP20 and operates with a control voltage (AC) of 33.6-46.2Vac (42Vac nominal; 50Hz; 0.8...1.1 x Uc) and 35.7-46.2Vac (42Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts, with a rated impulse voltage (Uimp) of 6 kV. The rated active power (kW) spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac (AC-3), and it also features 2 Normally Closed (NC) auxiliary contacts, with contact types of 1NO+1NC instantaneous aux. contacts per contactor. The rated power (HP) ranges from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, with a phase-to-phase rated voltage (AC) of 690 V. | Schneider Electric | Quick Quote | |||
LC2D40E7 Schneider Electric LC2D40E7 is a pre-assembled reversing magnetic contactor from the Deca sub-range, featuring a mechanical interlock design and screw connections. It comprises 2 x 3-poles (2x3P; 2x3NO) with a rated current of 60A (AC-1) and 40A (440Vac; AC-3). The contactor offers a degree of protection of IP20 and operates with a control voltage (AC) of 38.4-52.8Vac (48Vac nominal; 50Hz; 0.8...1.1 x Uc) and 40.8-52.8Vac (48Vac nominal; 60Hz; 0.85...1.1 x Uc). Its rated operating voltage (Ue) is 690 V, and it includes 2 Normally Open (NO) auxiliary contacts and 2 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) ranges from 11kW at 220-230Vac to 30kW at 660-690Vac, all within AC-3 classification. Each contactor has 1NO+1NC instantaneous auxiliary contacts, and the rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1DT80AX7 Schneider Electric LC1DT80AX7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for screw connections. This 4-pole (4P; 4NO) contactor is rated for 80A (AC-1) and is designed for DIN rail mounting. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage for AC ranges from 480-660Vac (600Vac nominal; 50Hz; 0.8...1.1 x Uc) to 510-660Vac (600Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with a contact type of 1NO+1NC instantaneous auxiliaries. The rated impulse voltage (Uimp) is 6 kV, and it has a mechanical durability of 6,000,000 operations at no load. The rated voltage (AC) phase-to-phase is 690 V. | Schneider Electric | Quick Quote | |||
LC1D80008T6 Schneider Electric LC1D80008T6 is a magnetic contactor from the Deca sub-range, designed with screw connections and four poles (4P; 2NO+2NC). It has a rated current of 125A (AC-1) and is suitable for DIN rail mounting. The net width of the contactor is 96 mm, and it offers a degree of protection of IP20. The control voltage (AC) ranges from 408-528Vac (480Vac nominal; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. This model does not include normally open (NO) or normally closed (NC) auxiliary contacts. It is capable of withstanding a rated impulse voltage (Uimp) of 8 kV and has a mechanical durability of 4 million operations at no load. The rated voltage (AC) for phase-to-phase connections is 1000 V. | Schneider Electric | Quick Quote | |||
LC1D65A6FC7 Schneider Electric LC1D65A6FC7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminal design and ring-lugs connections. This 3-pole (3P; 3NO) contactor has a rated current of 80A for AC-1 and 65A for 440Vac in AC-3. It is designed for DIN rail mounting with a net width of 55 mm and offers a degree of protection of IP20. The control voltage (AC) ranges from 102-139Vac at 50Hz and 108-139Vac at 60Hz, with a nominal control voltage of 127Vac. The rated operating voltage (Ue) is up to 690 V, and it includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. Its rated active power spans from 18.5kW at 220-230Vac to 37kW at 660-690Vac in AC-3. The rated power in horsepower (HP) varies from 5HP at 115Vac in single-phase to 50HP at 575-600Vac in three-phase, under UL/CSA standards. The mechanical durability of the LC1D65A6FC7 is rated at 6 million operations at no load, and its electrical durability is rated at 1.4 million operations with load. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1D506FW Schneider Electric LC1D506FW is a magnetic contactor from the Deca sub-range designed with a wide-range coil (0.75-1.2 x Uc) for flexibility in control voltage, which ranges from 82.5-132Vdc (110Vdc nominal). It features ring-lugs connections for secure wiring and is equipped with 3 poles (3P; 3NO) suitable for various applications. The contactor supports a rated current of 80A under AC-1 conditions and 50A at 440Vac under AC-3 conditions. It is designed for DIN rail mounting and offers an IP20 degree of protection. The rated operating voltage (Ue) is up to 690 V, and it includes 1 Normally Open (NO) auxiliary contact. The rated impulse voltage (Uimp) is 6 kV. Its rated active power capacity spans from 15kW at 220-230Vac to 33kW at 660-690Vac under AC-3 conditions. Additionally, it has 1 Normally Closed (NC) auxiliary contact with contacts type of 1NO+1NC instantaneous aux. The rated power in horsepower (HP) varies from 3HP at 115Vac to 40HP at 575-600Vac, accommodating a wide range of motor applications. The mechanical durability of the LC1D506FW is rated at 15 million operations at no load, and its phase-to-phase rated voltage (AC) reaches up to 690 V. | Schneider Electric | Quick Quote | |||
LC1D40AMD Schneider Electric LC1D40AMD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections. It is a 3-pole (3P; 3NO) contactor with a rated current of 60A for AC-1 and 40A for 440Vac in AC-3. Designed for DIN rail mounting, it has a net width of 55 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 165-275Vdc (220Vdc nominal; 0.75...1.25 x Uc), and the rated operating voltage (Ue) is up to 690 V. It includes 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV. This contactor supports rated active power ranging from 11kW at 220-230Vac to 30kW at 660-690Vac in AC-3, and rated power (HP) from 3HP at 115Vac to 30HP at 575-600Vac, according to UL/CSA standards for single-phase and 3-phase connections. It boasts a mechanical durability of 6,000,000 operations and an electrical durability of 1,500,000 operations with load, with a phase-to-phase rated voltage (AC) of 690 V. | Schneider Electric | Quick Quote | |||
LC1D40A6FE7 Schneider Electric LC1D40A6FE7 is a magnetic contactor from the Deca sub-range featuring EverLink(TM) terminals and ring-lugs connections. This 3-pole (3P; 3NO) contactor is designed for DIN rail mounting and has a net width of 55 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) of 92-126Vac (115Vac nominal; 50Hz; 0.8...1.1 x Uc) and 98-126Vac (115Vac nominal; 60Hz; 0.85...1.1 x Uc). The rated operating voltage (Ue) is 690 V, and it comes with 1 normally open (NO) auxiliary contact and 1 normally closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The rated current is 60A (AC-1) and 40A (440Vac; AC-3), with a rated impulse voltage (Uimp) of 6 kV. It supports rated active power of 11kW (220-230Vac; AC-3) up to 30kW (660-690Vac; AC-3) and rated power (HP) ranging from 3HP (115Vac; single-phase; 50Hz/60Hz; UL/CSA) to 30HP (575-600Vac; 3-phase; 50Hz/60Hz; UL/CSA). The mechanical durability is rated at 6,000,000 operations, and electrical durability (with load) at 1,500,000 operations. The rated voltage (AC) - phase-to-phase is 690 V. | Schneider Electric | Quick Quote |