| PSU67-3P-1H2-1H0-24250-IOL Smart Power Supply Module in IP67, 24…28 VDC Output Voltage, 3-Phase, 25-A Output Current, IO-Link Interface, Operating voltage 320…550 VAC, Broad temperature range, Status LED, High efficiency, > 95 %, 3-phase AC input, Han Q4/2, 24 VDC output, 1 × Han Q4/0, IO-Link interface for checking and parameterization, LED interface and control buttons for maximum flexibility | Turck | $790.10 | |
| CP20.242 PULS CP20.242 is a DIN rail mounting power supply unit enclosed in an aluminium housing, designed for a wide range of industrial automation applications. It operates within an ambient air temperature range of -25 to +70°C and offers various current consumption rates depending on the input voltage, including 2.23A at 230Vac, 4.26A at 120Vac, 5.15A at 100Vac, 4.64A at 110Vdc, and 1.66A at 300Vdc, with peak inrush currents of 5.5A at 230Vac and 12A at 120Vac. The unit features an IP20 degree of protection and achieves high efficiency rates of 0.956 at 230Vac and 0.942 at 120Vac. Its dimensions are W48mm x H124mm x D127mm. The CP20.242 includes a 450ms start-up delay and rise times of 145ms and 160ms under different load conditions. It is equipped with protection functions against output overvoltage and overload/short-circuit scenarios, and supports series or parallel operation for increased output voltages or power, including 1+1 redundancy with a redundancy module. The power dissipation/losses are 22.1W at 230Vac and 29.6W at 120Vac, with an output stage capacitance of 8500µF. Its electrical durability varies with temperature and output current, offering up to 488000 hours of operation under certain conditions. The ripple is maintained at 50mVpp across a wide frequency range. This AC/DC power supply unit, part of the CP-series, is designed for enhanced DC input and includes a 20% power reserve, DC-OK relay contact output, and screw-clamp connections. It accepts a supply voltage range of 88Vdc-360Vdc and 85Vac-264Vac, with specific tolerances for over and under voltages, and provides a rated current of 24A at 24Vdc in temperatures up to +45°C, with derating at higher temperatures. The rated power is 576W at temperatures up to +45°C, decreasing linearly up to +70°C. The output voltage is adjustable between 24Vdc and 28Vdc, with a 200mV turn-ON overshoot and a hold time of 32ms at standard input voltages. | Puls | $570.00 | |
| CS10.481 PULS CS10.481 is a DIN rail mounting power supply unit encased in an aluminium housing, designed for a wide range of industrial applications. It operates within an ambient air temperature range of -25 to +70°C. The unit has a net width of 60mm and dimensions of W60mm x H124mm x D117mm. It features a current consumption of 2.23A with a 230Vac input for full 48Vdc output, 3.73A with a 120Vac input, and 4.34A with a 100Vac input, alongside a peak max. inrush of 10A across all input voltages. The efficiency rates are 0.916 for 230Vac input, 0.91 for 120Vac input, and 0.907 for 100Vac input. The CS10.481 has a start-up delay of 850ms and rise times of 51ms and 96ms under specified conditions. It includes protection functions such as output overvoltage protection and overload/short-circuit current protection, with capabilities for series/parallel operation for redundancy. The unit is resistant to back-feeding loads up to 63V. Power dissipation/losses are 22W for 230Vac input and 23.7W for 120Vac input, with an output stage capacitance of 3100µF. Electrical durability varies with conditions, reaching up to 346000 hours. The ripple is specified at 100mVpp. This AC/DC power supply unit, part of the C-Line series, offers a 20% power reserve, DC-OK relay contact output, and screw-clamp connections. It supports a supply voltage range of 85Vac-132Vac / 184Vac-264Vac with auto select and has a rated current of 6A at 48Vdc for ambient temperatures less than 45°C. The output voltage is adjustable between 48Vdc and 52Vdc, with a hold time of 47ms at 230Vac input. | Puls | $465.00 | |
| ML100.105 PULS ML100.105 is a power supply unit (PSU) / converter designed for AC/DC applications with DIN rail mounting. It operates within an ambient air temperature range of -10 to +70°C and offers a rated current of 2.1A at 48Vdc, with a power derating from 2.5W at +60°C to +70°C. The unit features spring-clamp connections for secure and reliable connectivity. It supports a wide range of supply voltages, including AC inputs from 85Vac to 132Vac and 184Vac to 264Vac across various nominal values (100Vac, 110Vac, 120Vac, 200Vac, 208Vac, 220Vac, 230Vac, 240Vac) with auto-selection and a frequency range of 47-63Hz, as well as DC inputs from 213Vdc to 377Vdc (220Vdc, 250Vdc nominal). The ML100.105 measures 73mm in width, 75mm in height, and 103mm in depth, and is housed in a PC / ABS blend for durability. It is compatible with single-phase (1AC) or DC networks, has a net width of 73 mm, and provides a rated power of 100W. The output voltage is adjustable between 48Vdc and 56Vdc, achieving an efficiency of 0.91 with a 230Vac input. The unit's current consumption includes a maximum inrush of 22A at 120Vac input and 37A peak at 230Vac input. Power dissipation/losses are rated at 10W, and the ripple is specified at 50mVpp over a frequency range of 20Hz to 20MHz at 50Ω. | Puls | $304.00 | |
| UB20.241 PULS UB20.241 is an Uninterruptible Power Supply (UPS) control module from the UB-series, designed with an external battery and a green status LED. This module features a DC/DC UPS control mechanism, encased in an aluminium housing, and utilizes screw-clamp connections for secure installation. It measures W46mm x H124mm x D127mm and operates on a supply voltage range of 18Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 20A at 22.5Vdc, with a capability to support 30A in buffer mode for less than 5 seconds at full output voltage. In normal mode, Output 1 can deliver 25A, and in buffer mode, it can deliver 20A/30A (720W for up to 5s). Designed for DIN rail mounting, it can operate in ambient air temperatures ranging from -40 to +70°C. The current consumption is 2.1A with a 24Vdc input, and a maximum of 2.3A. It supports a DC network type and includes visual position indicators for Ready, Buffering, Inhibit, and Replace Battery statuses. Protection functions include output overvoltage protection with typical 32Vdc and maximum 35Vdc. It allows for the construction of a system with higher output current using 2 DC-UPS, 2 individual power supplies, 2 battery modules, and 1 decoupling module. The output voltage in buffer mode is selectable between 22.5Vdc, 24Vdc, 25Vdc, and 26Vdc, with an efficiency of 0.99 at 24Vdc input. The rated power is 600W at 24Vdc and 480W/720W in buffer mode, with power dissipation/losses ranging from 1.9W to 4.8W depending on the output current. Ripple is maintained at 120mVpp across a frequency range of 20Hz to 20MHz at 50Ω. Electrical durability spans from 440,000 hours to 1,244,000 hours at 25°C, depending on the output current and operating temperature. | Puls | $700.00 | |
| CD5.051 PULS CD5.051 is a power supply unit designed for DIN rail mounting, featuring an aluminium housing with dimensions of W32mm x H124mm x D102mm. It operates within an ambient air temperature range of -25 to +70°C and has a net width of 32 mm. The unit consumes 2.6A current at a 24Vdc input for a full 5Vdc output at 10A, with a peak inrush current of 1.6A. It offers an efficiency of 0.815 at 5.1Vdc 10A input and is protected by an IP20 degree of protection. The CD5.051 includes a 420ms start-up delay, a 300ms rise time at nominal input with a constant full current load and 0mF load capacitance, and a 350ms rise time with an 8mF load capacitance. It features output overvoltage protection, overload protection, no-load and short-circuit protection with a short-circuit current of min. 12A to max. 20A, over-temperature protection with automatic restart, and allows for series/parallel operation for increased output power or redundancy. The unit is resistant to back-feeding loads up to 5.6V, includes reverse polarity protection, and has a power dissipation/loss of 11.5W at a 24Vdc input with a 5.1V output load at 10A. The output stage capacitance is 16000 µF, with a ripple of 50mVpp across 20Hz to 20MHz at 50Ω. It functions as a power supply unit or DC/DC-converter with a 20% power reserve, belonging to the CD-series and designed with galvanic isolation and screw-clamp connections. The supply voltage ranges from 18Vdc to 32.4Vdc (24Vdc nominal) and 14.4-18Vdc for a maximum of 60 seconds. It has a rated current of 12A at 5Vdc from -25 to +45°C and 10A at 5Vdc from +45 to +60°C, with a derating of 1.25W from +60 to +70°C. The rated power is 60W at -25 to +45°C and 50W at -25 to +60°C, with an adjustable output voltage of 5Vdc to 5.5Vdc and a 250mV turn-ON overshoot. The hold time is 10ms at a 24Vdc input. | Puls | $425.00 | |
| UF20.241 PULS UF20.241 is an Uninterruptible Power Supply (UPS) control module, part of the UF-series, designed as a buffer module with capacitor storage featuring a green status LED. This product is housed in aluminum and utilizes spring-clamp connections for secure installation. It measures W64mm x H124mm x D102mm and is designed for DIN rail mounting. The UF20.241 operates with a supply voltage range of 19.2Vdc to 30Vdc, with a nominal voltage of 24Vdc, and supports a rated current of 20A before fusing. It is engineered to function within an ambient air temperature range of -25 to +70°C and is suitable for DC networks. The module includes a visual position indicator for Ready, Buffering, and Inhibit statuses. It offers protection functions including output overvoltage protection, with typical protection at 32Vdc and a maximum of 35Vdc. The UF20.241 allows for parallel connection of buffer modules to enhance output ampacity or hold-up time. It delivers a fixed output voltage of 24Vdc, boasts an efficiency of 0.99 with a 24Vdc input, and provides a hold time of 31ms / 0.31s at a 20A load. Power dissipation is calculated at 1.9 W for a 24Vdc input at 20A output current, with a ripple of 200mVpp across a frequency range of 20Hz to 20MHz at 50Ω. Its electrical durability is rated at 166,000 hours in standby mode at 40°C and 469,000 hours at 25°C. | Puls | $460.00 | |
| CP10.121 PULS CP10.121 is a DIN rail mounting power supply unit enclosed in an aluminium housing, designed for an ambient air temperature range of -25 to +70°C. It features a net width of 39mm and dimensions of W39mm x H124mm x D117mm. The unit has a current consumption of 11A peak max. inrush at 230Vac input and 7A peak max. inrush at 120Vac input. Its efficiency rates are 0.943 at 230Vac input, 0.928 at 120Vac input, and 0.921 at 100Vac input. The CP10.121 offers a start-up delay of 240-300ms for 100-230Vac input, with rise times of 18ms and 35ms under specified conditions. It includes protection functions such as output overvoltage protection and overload/short-circuit current protection, with capabilities for series/parallel operation and resistance to back-feeding loads up to 25V. Power dissipation/losses are 11.6W at 230Vac input and 14.9W at 120Vac input, with an output stage capacitance of 5350µF. Electrical durability spans from 40,000 to 534,000 hours under various conditions. The unit exhibits a ripple of 50mVpp and includes functions like AC/DC conversion with a 20% power reserve. It is part of the CP-series, featuring ATEX approval, shutdown input, and a DC-OK relay contact output. Connection is facilitated through screw-clamp connections, supporting a supply voltage range of 88Vdc-180Vdc and 85Vac-264Vac, with a rated current of 16A at 12Vdc, and a rated power of 192W. The output voltage is adjustable between 12Vdc and 15Vdc, with a 200mV turn-ON overshoot and a hold time of 50ms. | Puls | $390.00 | |
| UC10.242 PULS UC10.242 is an Uninterruptible Power Supply (UPS) control module within the UC-series, featuring a bfr. module design with capacitive storage, separated inputs and outputs, and a green status LED. This DC/DC UPS control module is encased in an aluminium housing and utilizes spring-clamp connections for connectivity. It measures W198mm x H124mm x D117mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 15A, both nominal and before (bfr.), and it is designed for DIN rail mounting. The UC10.242 can operate in ambient air temperatures ranging from -40 to +60°C and has a current consumption of 1.1A at a 24Vdc input. It supports a DC network type and includes visual position indicators for Ready, Buffering, Inhibit, and PC-mode. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. Series or parallel operation is not supported. The output voltage is a fixed 24Vdc, with a turn-ON voltage of 23Vdc, and it boasts an efficiency of 0.978 at a 24Vdc input. The rated power is 360W at 24Vdc, with hold times of 33 seconds at 10A and 18 seconds at 15A. Power dissipation/losses are 2.9W at 0A output current and 4.6W at 10A output current, with a ripple of 30mVpp across 20Hz to 20MHz at 50Ω. Electrical durability ranges from 324000 hours at 25°C and 10A output to 34000 hours at 55°C and 15A output. The capacitance at the output stage is 1500µF. | Puls | $1,500.00 | |
| UBC10.241-N1 PULS UBC10.241-N1 is an Uninterruptible Power Supply (UPS) control module from the U-series, featuring a built-in battery design (battery not assembled) with a 50% power reserve and a green status LED. This module is housed in an aluminium casing and utilizes spring-clamp connections for its connections. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can handle 15A in buffer mode for less than 5 seconds at full output voltage, with output 1 in normal mode at 15A and in buffer mode at 10A/15A (360W). Designed for DIN rail mounting, it operates within an ambient air temperature range of 0 to +40°C and has a current consumption of 1.1A at 24Vdc input. The network type is DC, and it features visual position indicators for Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection (32Vdc typical, 35Vdc maximum) and overload/short-circuit current protection—minimum 17.9A to maximum 21A at load impedance. It is not designed for parallel use to increase output power but supports 1+1 redundancy for enhanced system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. Its efficiency is rated at 0.978 with a 24Vdc input, and it has a rated power of 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W at 24Vdc input with 0A output current and 5.5W at 24Vdc input with 10A output current. Ripple is 20mVpp across 20Hz to 20MHz at 50Ω. Electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, and 15 years/131400 hours at both 40°C with a 5A output and 25°C with a 10A output, all at 24Vdc input. | Puls | $600.00 | |