Square D by Schneider Electric QO12024L125GI is a load center designed for interior replacement purposes. It features a rated current of 125A and accommodates up to 20 spaces. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is suitable for single-phase (1PH-3W) networks, with a rated voltage of 120Vac/240Vac. It supports 24 single pole circuits and 4 tandem breakers, providing flexibility in circuit management. Additionally, it has a short circuit breaking rating of 65kA, indicating its capability to handle significant fault currents.
Quick Quote
Square D by Schneider Electric QO116M100PC is a load center designed for single-phase (1PH-3W) networks, featuring a QOM1 frame size and a Plug-on-Neutral (PoN) configuration. It has a rated current of 100A and operates at a rated voltage of 120Vac/240Vac. The dimensions of this load center are H455mm x W362mm x D95mm (H17.92" x W14.25" x D3.75"), and it offers 16 spaces for single pole circuits or 8 tandem breakers. It comes with a NEMA 1 degree of protection and has a short circuit breaking rating of 22kA.
Quick Quote
Square D by Schneider Electric QO116M10070 is a load center designed with a QOM1 frame size and a rated current of 100A. It features a connection type of lugs and dimensions of H455mm x W362mm (H17.91" x W14.25"), accommodating 16 spaces. This load center is protected by a NEMA 1 degree of protection and is constructed from welded sheet steel for the enclosure and tin-plated copper for the busbar. It is suitable for a single-phase (1PH-3W) network with a rated voltage of 120Vac/240Vac. The QO116M10070 can support up to 16 single pole circuits and has a short circuit breaking rating of 22kA.
Quick Quote
Square D by Schneider Electric QO11624L125GRBI is a load center designed for interior replacement applications. It features a rated current of 125A and accommodates up to 16 spaces. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is compatible with a single-phase (1PH-3W) network and operates at a rated voltage of 120Vac/240Vac. It can support 24 single pole circuits and 8 tandem breakers, with a short circuit breaking rating of 65kA.
Quick Quote
Square D by Schneider Electric QO112L125GRBI is a load center designed for load center (LC) interior replacement applications. It features a rated current of 125A and accommodates 12 single pole circuits within its 12-space configuration. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is compatible with a single-phase (1PH-3W) network and operates at a rated voltage of 120Vac/240Vac. It also boasts a short circuit breaking rating of 65kA, suitable for various electrical distribution needs.
Quick Quote
Square D by Schneider Electric QO112L125GI is a load center designed for LC interior replacement applications. It features a rated current of 125A and accommodates 12 single pole circuits within its 12-space configuration. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is compatible with a single-phase (1PH-3W) network and operates at a rated voltage of 120Vac/240Vac. It also boasts a short circuit breaking rating of 65kA, highlighting its capability to handle significant fault currents.
Quick Quote
Square D by Schneider Electric QO11224L125GWGCI is a load center designed for single-phase (1PH-3W) networks with a rated voltage of 120Vac/240Vac. It features a rated current of 125A and accommodates up to 24 single pole circuits or 12 tandem breakers within its 12-space configuration. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is specifically engineered for load center (LC) interior replacement and boasts a short circuit breaking rating of 65kA.
Quick Quote
Square D by Schneider Electric CQO140M150RB is a load center designed with a tin-plated copper busbar. It features a NEMA 3R degree of protection, making it suitable for certain outdoor applications. The dimensions of this load center are H864mm x W362mm (H34.02" x W14.25"), and it offers 40 spaces. It operates at a rated voltage of 120Vac/240Vac and is capable of supporting 80 single pole circuits. The rated current for this device is 150A, and it is compatible with a single-phase (1PH-3W) network. The connection type utilized is lugs, and it has a short circuit breaking rating of 22kA.
Quick Quote
Square D by Schneider Electric CQO132M150C is a load center designed with a tin-plated copper busbar. It features a NEMA 1 degree of protection and measures H667mm x W362mm x D95mm (H26.26" x W14.25" x D3.74"), providing 32 spaces for circuit installation. This load center operates at a rated voltage of 120Vac/240Vac and is capable of supporting 64 single pole circuits with a rated current of 150A. It is designed for a single-phase (1PH-3W) network and offers a short circuit breaking rating of 22kA. The connection to the load center is made through lugs.
Quick Quote
Square D by Schneider Electric CQO132M125C60 is a load center designed with a tin-plated copper busbar. It features a NEMA 1 degree of protection and measures H667mm x W362mm x D95mm (H26.26" x W14.25" x D3.74"), offering 32 spaces for circuit installation. This load center operates at a rated voltage of 120Vac/240Vac and is capable of supporting 54 single pole circuits with a rated current of 60A. It is designed for a single-phase (1PH-3W) network and has a short circuit breaking rating of 22kA. The connection type utilized is lugs.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
QO12024L125GI Square D by Schneider Electric QO12024L125GI is a load center designed for interior replacement purposes. It features a rated current of 125A and accommodates up to 20 spaces. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is suitable for single-phase (1PH-3W) networks, with a rated voltage of 120Vac/240Vac. It supports 24 single pole circuits and 4 tandem breakers, providing flexibility in circuit management. Additionally, it has a short circuit breaking rating of 65kA, indicating its capability to handle significant fault currents. | Schneider Electric | Quick Quote | |||
QO116M100PC Square D by Schneider Electric QO116M100PC is a load center designed for single-phase (1PH-3W) networks, featuring a QOM1 frame size and a Plug-on-Neutral (PoN) configuration. It has a rated current of 100A and operates at a rated voltage of 120Vac/240Vac. The dimensions of this load center are H455mm x W362mm x D95mm (H17.92" x W14.25" x D3.75"), and it offers 16 spaces for single pole circuits or 8 tandem breakers. It comes with a NEMA 1 degree of protection and has a short circuit breaking rating of 22kA. | Schneider Electric | Quick Quote | |||
QO116M10070 Square D by Schneider Electric QO116M10070 is a load center designed with a QOM1 frame size and a rated current of 100A. It features a connection type of lugs and dimensions of H455mm x W362mm (H17.91" x W14.25"), accommodating 16 spaces. This load center is protected by a NEMA 1 degree of protection and is constructed from welded sheet steel for the enclosure and tin-plated copper for the busbar. It is suitable for a single-phase (1PH-3W) network with a rated voltage of 120Vac/240Vac. The QO116M10070 can support up to 16 single pole circuits and has a short circuit breaking rating of 22kA. | Schneider Electric | Quick Quote | |||
QO11624L125GRBI Square D by Schneider Electric QO11624L125GRBI is a load center designed for interior replacement applications. It features a rated current of 125A and accommodates up to 16 spaces. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is compatible with a single-phase (1PH-3W) network and operates at a rated voltage of 120Vac/240Vac. It can support 24 single pole circuits and 8 tandem breakers, with a short circuit breaking rating of 65kA. | Schneider Electric | Quick Quote | |||
QO112L125GRBI Square D by Schneider Electric QO112L125GRBI is a load center designed for load center (LC) interior replacement applications. It features a rated current of 125A and accommodates 12 single pole circuits within its 12-space configuration. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is compatible with a single-phase (1PH-3W) network and operates at a rated voltage of 120Vac/240Vac. It also boasts a short circuit breaking rating of 65kA, suitable for various electrical distribution needs. | Schneider Electric | Quick Quote | |||
QO112L125GI Square D by Schneider Electric QO112L125GI is a load center designed for LC interior replacement applications. It features a rated current of 125A and accommodates 12 single pole circuits within its 12-space configuration. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is compatible with a single-phase (1PH-3W) network and operates at a rated voltage of 120Vac/240Vac. It also boasts a short circuit breaking rating of 65kA, highlighting its capability to handle significant fault currents. | Schneider Electric | Quick Quote | |||
QO11224L125GWGCI Square D by Schneider Electric QO11224L125GWGCI is a load center designed for single-phase (1PH-3W) networks with a rated voltage of 120Vac/240Vac. It features a rated current of 125A and accommodates up to 24 single pole circuits or 12 tandem breakers within its 12-space configuration. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is specifically engineered for load center (LC) interior replacement and boasts a short circuit breaking rating of 65kA. | Schneider Electric | Quick Quote | |||
CQO140M150RB Square D by Schneider Electric CQO140M150RB is a load center designed with a tin-plated copper busbar. It features a NEMA 3R degree of protection, making it suitable for certain outdoor applications. The dimensions of this load center are H864mm x W362mm (H34.02" x W14.25"), and it offers 40 spaces. It operates at a rated voltage of 120Vac/240Vac and is capable of supporting 80 single pole circuits. The rated current for this device is 150A, and it is compatible with a single-phase (1PH-3W) network. The connection type utilized is lugs, and it has a short circuit breaking rating of 22kA. | Schneider Electric | Quick Quote | |||
CQO132M150C Square D by Schneider Electric CQO132M150C is a load center designed with a tin-plated copper busbar. It features a NEMA 1 degree of protection and measures H667mm x W362mm x D95mm (H26.26" x W14.25" x D3.74"), providing 32 spaces for circuit installation. This load center operates at a rated voltage of 120Vac/240Vac and is capable of supporting 64 single pole circuits with a rated current of 150A. It is designed for a single-phase (1PH-3W) network and offers a short circuit breaking rating of 22kA. The connection to the load center is made through lugs. | Schneider Electric | Quick Quote | |||
CQO132M125C60 Square D by Schneider Electric CQO132M125C60 is a load center designed with a tin-plated copper busbar. It features a NEMA 1 degree of protection and measures H667mm x W362mm x D95mm (H26.26" x W14.25" x D3.74"), offering 32 spaces for circuit installation. This load center operates at a rated voltage of 120Vac/240Vac and is capable of supporting 54 single pole circuits with a rated current of 60A. It is designed for a single-phase (1PH-3W) network and has a short circuit breaking rating of 22kA. The connection type utilized is lugs. | Schneider Electric | Quick Quote |