Square D by Schneider Electric HOM20M100CI is a spare part designed for interior replacement, featuring a 20-space configuration. It is constructed with a tin-plated aluminium busbar. This part has a rated current of 100A and operates at a rated voltage of 120Vac/240Vac, suitable for single-phase (1PH) networks. It also boasts a short circuit breaking rating of 22kA.
Quick Quote
Square D by Schneider Electric QO342M225RBI is a load center designed to manage electrical distribution within a facility. It features a rated current of 225A and accommodates up to 42 single pole circuits within its 42-space configuration. The busbar is made from tin-plated copper, ensuring conductivity and resistance to corrosion. This load center operates at a rated voltage of 120Vac/240Vac and has a short circuit breaking rating of 25kA, providing a robust solution for circuit protection and power distribution.
Quick Quote
Square D by Schneider Electric QO140L200GRBI is a load center designed for LC interior replacement with a rated current of 200A. It accommodates up to 40 single pole circuits within its 40-space configuration. The busbar is made from tin-plated copper, ensuring compatibility with single-phase (1PH-3W) networks at a rated voltage of 120Vac/240Vac. This load center is engineered with a short circuit breaking rating of 65kA.
Quick Quote
Square D by Schneider Electric CQO160M225C is a load center designed with a tin-plated copper busbar. It features a NEMA 1 degree of protection and measures H1048mm x W362mm x D115mm (H41.26" x W14.25" x D4.53"), offering 60 spaces. This load center operates at a rated voltage of 120Vac/240Vac and is equipped for load center (LC) functions with a connection type of lugs. It supports up to 80 single pole circuits with a rated current of 225A. The CQO160M225C is suitable for a single-phase (1PH-3W) network and has a short circuit breaking rating of 22kA.
Quick Quote
Square D by Schneider Electric CQO112M100C50 is a load center designed with a tin-plated copper busbar. It features a NEMA 1 degree of protection and measures H381mm x W362mm x D95mm (H15" x W14.25" x D3.74"), with 12 spaces available. This load center operates at a rated voltage of 120Vac/240Vac and is capable of supporting 24 single pole circuits. It has a rated current of 50A and is suitable for a single-phase (1PH-3W) network. The connection type utilized is lugs, and it has a short circuit breaking rating of 65kA.
Quick Quote
Square D by Schneider Electric CQO112M100C40 is a load center designed with a tin-plated copper busbar. It features a NEMA 1 degree of protection and measures H381mm x W362mm x D95mm (H15" x W14.25" x D3.74") with 12 spaces. This load center operates at a rated voltage of 120Vac/240Vac and is equipped for load center (LC) functions. It offers a connection type of lugs and can accommodate up to 24 single pole circuits. The rated current for this device is 40A, and it is compatible with a single-phase (1PH-3W) network. Additionally, it has a short circuit breaking rating of 65kA.
Quick Quote
Square D by Schneider Electric EZM313200 is a meter center branch unit designed for surface mounting. It features a steel enclosure and an aluminium busbar, ensuring compatibility with a three-phase (3PH-4W) network. This unit is equipped with a NEMA 3R degree of protection, suitable for outdoor use. It operates at a rated voltage of 208Y/120Vac and includes metering center branch functionality with three phases in and one phase out. The EZM313200 comes with 5 jaws (without jaw release) and 3 ringed meter sockets, but does not include a bypass. It supports a main rated current of 200A and a busbar rated current of 800A.
Quick Quote
Square D by Schneider Electric HOM1427X2242M200PC is a load center designed as a generator ready split-bus panel. It features dimensions of H1000mm x W361mm x D95mm (H39.37" x W14.21" x D3.74") and is built to NEMA 1 degree of protection standards.
Quick Quote
Square D by Schneider Electric SO2040M200SS is a Combination Service Entrance Device (CSED) that features a single ringed meter socket without a bypass. It is designed for surface mounting and offers 20 spaces for up to 40 single pole circuits or 20 tandem breakers. The device is rated for a current of 200A and has a short circuit breaking rating of 22kA. For connections, it accommodates 6AWG to 350kcmil aluminium/copper lugs for line connections and 8AWG to 2/0AWG aluminium/copper lugs for ground connections.
Quick Quote
Square D by Schneider Electric QO142M200T2 is a load center designed for single-phase (1PH-3W) networks, with a rated voltage of 120Vac/240Vac and a rated current of 200A. It features a connection type of lugs and offers 42 spaces for single pole circuits. The load center, which fits a QOM1 frame size, has a short circuit breaking rating of 22kA. It is housed in a welded sheet steel enclosure with dimensions of H965mm x W362mm (H37.99" x W14.25") and provides a degree of protection classified as NEMA 1. The busbar is made from tin-plated copper, ensuring a robust connection point for circuits.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
HOM20M100CI Square D by Schneider Electric HOM20M100CI is a spare part designed for interior replacement, featuring a 20-space configuration. It is constructed with a tin-plated aluminium busbar. This part has a rated current of 100A and operates at a rated voltage of 120Vac/240Vac, suitable for single-phase (1PH) networks. It also boasts a short circuit breaking rating of 22kA. | Schneider Electric | Quick Quote | |||
QO342M225RBI Square D by Schneider Electric QO342M225RBI is a load center designed to manage electrical distribution within a facility. It features a rated current of 225A and accommodates up to 42 single pole circuits within its 42-space configuration. The busbar is made from tin-plated copper, ensuring conductivity and resistance to corrosion. This load center operates at a rated voltage of 120Vac/240Vac and has a short circuit breaking rating of 25kA, providing a robust solution for circuit protection and power distribution. | Schneider Electric | Quick Quote | |||
QO140L200GRBI Square D by Schneider Electric QO140L200GRBI is a load center designed for LC interior replacement with a rated current of 200A. It accommodates up to 40 single pole circuits within its 40-space configuration. The busbar is made from tin-plated copper, ensuring compatibility with single-phase (1PH-3W) networks at a rated voltage of 120Vac/240Vac. This load center is engineered with a short circuit breaking rating of 65kA. | Schneider Electric | Quick Quote | |||
CQO160M225C Square D by Schneider Electric CQO160M225C is a load center designed with a tin-plated copper busbar. It features a NEMA 1 degree of protection and measures H1048mm x W362mm x D115mm (H41.26" x W14.25" x D4.53"), offering 60 spaces. This load center operates at a rated voltage of 120Vac/240Vac and is equipped for load center (LC) functions with a connection type of lugs. It supports up to 80 single pole circuits with a rated current of 225A. The CQO160M225C is suitable for a single-phase (1PH-3W) network and has a short circuit breaking rating of 22kA. | Schneider Electric | Quick Quote | |||
CQO112M100C50 Square D by Schneider Electric CQO112M100C50 is a load center designed with a tin-plated copper busbar. It features a NEMA 1 degree of protection and measures H381mm x W362mm x D95mm (H15" x W14.25" x D3.74"), with 12 spaces available. This load center operates at a rated voltage of 120Vac/240Vac and is capable of supporting 24 single pole circuits. It has a rated current of 50A and is suitable for a single-phase (1PH-3W) network. The connection type utilized is lugs, and it has a short circuit breaking rating of 65kA. | Schneider Electric | Quick Quote | |||
CQO112M100C40 Square D by Schneider Electric CQO112M100C40 is a load center designed with a tin-plated copper busbar. It features a NEMA 1 degree of protection and measures H381mm x W362mm x D95mm (H15" x W14.25" x D3.74") with 12 spaces. This load center operates at a rated voltage of 120Vac/240Vac and is equipped for load center (LC) functions. It offers a connection type of lugs and can accommodate up to 24 single pole circuits. The rated current for this device is 40A, and it is compatible with a single-phase (1PH-3W) network. Additionally, it has a short circuit breaking rating of 65kA. | Schneider Electric | Quick Quote | |||
EZM313200 Square D by Schneider Electric EZM313200 is a meter center branch unit designed for surface mounting. It features a steel enclosure and an aluminium busbar, ensuring compatibility with a three-phase (3PH-4W) network. This unit is equipped with a NEMA 3R degree of protection, suitable for outdoor use. It operates at a rated voltage of 208Y/120Vac and includes metering center branch functionality with three phases in and one phase out. The EZM313200 comes with 5 jaws (without jaw release) and 3 ringed meter sockets, but does not include a bypass. It supports a main rated current of 200A and a busbar rated current of 800A. | Schneider Electric | Quick Quote | |||
HOM1427X2242M200PC Square D by Schneider Electric HOM1427X2242M200PC is a load center designed as a generator ready split-bus panel. It features dimensions of H1000mm x W361mm x D95mm (H39.37" x W14.21" x D3.74") and is built to NEMA 1 degree of protection standards. | Schneider Electric | Quick Quote | |||
SO2040M200SS Square D by Schneider Electric SO2040M200SS is a Combination Service Entrance Device (CSED) that features a single ringed meter socket without a bypass. It is designed for surface mounting and offers 20 spaces for up to 40 single pole circuits or 20 tandem breakers. The device is rated for a current of 200A and has a short circuit breaking rating of 22kA. For connections, it accommodates 6AWG to 350kcmil aluminium/copper lugs for line connections and 8AWG to 2/0AWG aluminium/copper lugs for ground connections. | Schneider Electric | Quick Quote | |||
QO142M200T2 Square D by Schneider Electric QO142M200T2 is a load center designed for single-phase (1PH-3W) networks, with a rated voltage of 120Vac/240Vac and a rated current of 200A. It features a connection type of lugs and offers 42 spaces for single pole circuits. The load center, which fits a QOM1 frame size, has a short circuit breaking rating of 22kA. It is housed in a welded sheet steel enclosure with dimensions of H965mm x W362mm (H37.99" x W14.25") and provides a degree of protection classified as NEMA 1. The busbar is made from tin-plated copper, ensuring a robust connection point for circuits. | Schneider Electric | Quick Quote |