Square D by Schneider Electric QO142M200PCMR is a load center designed for both surface and flush mounting. It features a QOM1 frame size with a Plug-on-Neutral (PoN) configuration. This load center is rated for a current of 200A and utilizes feed-thru lugs for its connection type. Its dimensions are H965mm x W362mm x D95mm (H37.99" x W14.25" x D3.74"), offering 42 spaces for circuits. It is built to a NEMA 1 degree of protection with an enclosure made of welded sheet steel and a busbar of tin-plated aluminium. The QO142M200PCMR is suitable for a single-phase (1PH-3W) network, operates at a rated voltage of 120Vac/240Vac, can accommodate 42 single pole circuits, and has a short circuit breaking rating of 22kA.
Quick Quote
Square D by Schneider Electric QO142L225GI is a load center designed for interior replacement purposes. It features a rated current of 225A and accommodates up to 42 single pole circuits within its 42-space configuration. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is compatible with a single-phase (1PH-3W) network and operates at a rated voltage of 120Vac/240Vac. It also boasts a short circuit breaking rating of 65kA, providing robust protection against electrical faults.
Quick Quote
Square D by Schneider Electric QO320L125I is a load center designed to manage electrical distribution with a rated current of 125A. It features a tin-plated copper busbar for enhanced conductivity and durability. This load center operates at a rated voltage of 120Vac/240Vac, accommodating up to 20 single pole circuits within its 20-space configuration. It is equipped with a neutral connection and boasts a short circuit breaking rating of 65kA, ensuring robust performance in circuit protection.
Quick Quote
Square D by Schneider Electric QO14252M200RBI is a load center designed for interior replacement with a rated current of 200A. It accommodates 42 spaces and is constructed with a tin-plated copper busbar. This single-phase (1PH-3W) load center operates at a rated voltage of 120Vac/240Vac. It supports up to 52 single pole circuits and 10 tandem breakers, with a short circuit breaking rating of 22kA.
Quick Quote
Square D by Schneider Electric QO14252L200GRB is a load center designed for surface mounting with a rated current of 200A and a connection type featuring lugs. It measures H965mm x W375mm (H37.99" x W14.76") and offers 42 spaces. This load center is built for a single-phase (1PH-3W) network with a rated voltage of 120Vac/240Vac. It can accommodate 52 single pole circuits and 10 tandem breakers. The enclosure is made from welded galvannealed steel, and the busbar from tin-plated copper, ensuring compatibility with 4AWG to 250kcmil aluminium and copper lugs. It has a degree of protection rated at NEMA 3R and a short circuit breaking rating of 65kA.
Quick Quote
Square D by Schneider Electric QO14252L200G is a load center designed for single-phase (1PH-3W) networks with a rated voltage of 120Vac/240Vac. It features a rated current of 200A and a connection type utilizing lugs. The dimensions of this load center are H965mm x W362mm (H37.99" x W14.25"), offering 42 spaces for circuit installation. It can accommodate 52 single pole circuits and 10 tandem breakers. The enclosure is made from welded sheet steel, while the busbar utilizes tin-plated copper, ensuring compatibility with both aluminium lugs (6AWG...300kcmil) and copper lugs (6AWG...300kcmil). This load center is designed with a degree of protection classified as NEMA 1 and has a short circuit breaking rating of 65kA.
Quick Quote
Square D by Schneider Electric QO14060M200 is a load center designed for single-phase (1PH-3W) networks, with a rated current of 200A and a rated voltage of 120Vac/240Vac. It features a QOM1 frame size and is capable of supporting up to 60 single pole circuits or 20 tandem breakers. The connection type is through lugs, accommodating cross-sections from 4AWG to 250kcmil for both aluminium and copper lugs. This load center is housed in a welded sheet steel enclosure with dimensions of H858mm x W362mm (H33.78" x W14.25") and offers 40 spaces. It is designed to meet NEMA 1 degree of protection standards and has a short circuit breaking rating of 22kA. The busbar is made from tin-plated copper, ensuring a robust connection point for the circuits it serves.
Quick Quote
Square D by Schneider Electric QO342MQ200QGL125 is a load center designed for three-phase (3PH-3W/4W) networks with a rated voltage of 120Vac/240Vac. It has a rated current of 200A and features a connection type utilizing lugs. This load center accommodates up to 42 single pole circuits within its dimensions of H1000mm x W362mm (H39.37" x W14.25") and offers 42 spaces for circuit installation. The degree of protection provided is NEMA 1, suitable for indoor use. It is constructed from welded sheet steel for the enclosure and tin-plated copper for the busbar, ensuring a robust physical structure and conductive path.
Quick Quote
Square D by Schneider Electric QO327M10060 is a load center designed for a rated current of 100A and a connection type utilizing lugs. It measures H758mm x W362mm (H29.84" x W14.25") and offers 27 spaces for single pole circuits. This load center is built with a welded sheet steel enclosure and tin-plated copper busbars, ensuring compatibility with a rated voltage of 120Vac/240Vac. It is equipped to handle a short circuit breaking rating of 25kA and is protected by a NEMA 1 degree of protection, making it suitable for various applications.
Quick Quote
Square D by Schneider Electric QO320L125RBI is a load center designed to accommodate up to 20 single pole circuits. It features a neutral load center (LC) configuration with a rated current of 125A. The dimensions of this load center allow for 20 spaces, and it is constructed with a tin-plated copper busbar. It operates at a rated voltage of 120Vac/240Vac and has a short circuit breaking rating of 65kA.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
QO142M200PCMR Square D by Schneider Electric QO142M200PCMR is a load center designed for both surface and flush mounting. It features a QOM1 frame size with a Plug-on-Neutral (PoN) configuration. This load center is rated for a current of 200A and utilizes feed-thru lugs for its connection type. Its dimensions are H965mm x W362mm x D95mm (H37.99" x W14.25" x D3.74"), offering 42 spaces for circuits. It is built to a NEMA 1 degree of protection with an enclosure made of welded sheet steel and a busbar of tin-plated aluminium. The QO142M200PCMR is suitable for a single-phase (1PH-3W) network, operates at a rated voltage of 120Vac/240Vac, can accommodate 42 single pole circuits, and has a short circuit breaking rating of 22kA. | Schneider Electric | Quick Quote | |||
QO142L225GI Square D by Schneider Electric QO142L225GI is a load center designed for interior replacement purposes. It features a rated current of 225A and accommodates up to 42 single pole circuits within its 42-space configuration. The busbar is made from tin-plated copper, ensuring conductivity and durability. This load center is compatible with a single-phase (1PH-3W) network and operates at a rated voltage of 120Vac/240Vac. It also boasts a short circuit breaking rating of 65kA, providing robust protection against electrical faults. | Schneider Electric | Quick Quote | |||
QO320L125I Square D by Schneider Electric QO320L125I is a load center designed to manage electrical distribution with a rated current of 125A. It features a tin-plated copper busbar for enhanced conductivity and durability. This load center operates at a rated voltage of 120Vac/240Vac, accommodating up to 20 single pole circuits within its 20-space configuration. It is equipped with a neutral connection and boasts a short circuit breaking rating of 65kA, ensuring robust performance in circuit protection. | Schneider Electric | Quick Quote | |||
QO14252M200RBI Square D by Schneider Electric QO14252M200RBI is a load center designed for interior replacement with a rated current of 200A. It accommodates 42 spaces and is constructed with a tin-plated copper busbar. This single-phase (1PH-3W) load center operates at a rated voltage of 120Vac/240Vac. It supports up to 52 single pole circuits and 10 tandem breakers, with a short circuit breaking rating of 22kA. | Schneider Electric | Quick Quote | |||
QO14252L200GRB Square D by Schneider Electric QO14252L200GRB is a load center designed for surface mounting with a rated current of 200A and a connection type featuring lugs. It measures H965mm x W375mm (H37.99" x W14.76") and offers 42 spaces. This load center is built for a single-phase (1PH-3W) network with a rated voltage of 120Vac/240Vac. It can accommodate 52 single pole circuits and 10 tandem breakers. The enclosure is made from welded galvannealed steel, and the busbar from tin-plated copper, ensuring compatibility with 4AWG to 250kcmil aluminium and copper lugs. It has a degree of protection rated at NEMA 3R and a short circuit breaking rating of 65kA. | Schneider Electric | Quick Quote | |||
QO14252L200G Square D by Schneider Electric QO14252L200G is a load center designed for single-phase (1PH-3W) networks with a rated voltage of 120Vac/240Vac. It features a rated current of 200A and a connection type utilizing lugs. The dimensions of this load center are H965mm x W362mm (H37.99" x W14.25"), offering 42 spaces for circuit installation. It can accommodate 52 single pole circuits and 10 tandem breakers. The enclosure is made from welded sheet steel, while the busbar utilizes tin-plated copper, ensuring compatibility with both aluminium lugs (6AWG...300kcmil) and copper lugs (6AWG...300kcmil). This load center is designed with a degree of protection classified as NEMA 1 and has a short circuit breaking rating of 65kA. | Schneider Electric | Quick Quote | |||
QO14060M200 Square D by Schneider Electric QO14060M200 is a load center designed for single-phase (1PH-3W) networks, with a rated current of 200A and a rated voltage of 120Vac/240Vac. It features a QOM1 frame size and is capable of supporting up to 60 single pole circuits or 20 tandem breakers. The connection type is through lugs, accommodating cross-sections from 4AWG to 250kcmil for both aluminium and copper lugs. This load center is housed in a welded sheet steel enclosure with dimensions of H858mm x W362mm (H33.78" x W14.25") and offers 40 spaces. It is designed to meet NEMA 1 degree of protection standards and has a short circuit breaking rating of 22kA. The busbar is made from tin-plated copper, ensuring a robust connection point for the circuits it serves. | Schneider Electric | Quick Quote | |||
QO342MQ200QGL125 Square D by Schneider Electric QO342MQ200QGL125 is a load center designed for three-phase (3PH-3W/4W) networks with a rated voltage of 120Vac/240Vac. It has a rated current of 200A and features a connection type utilizing lugs. This load center accommodates up to 42 single pole circuits within its dimensions of H1000mm x W362mm (H39.37" x W14.25") and offers 42 spaces for circuit installation. The degree of protection provided is NEMA 1, suitable for indoor use. It is constructed from welded sheet steel for the enclosure and tin-plated copper for the busbar, ensuring a robust physical structure and conductive path. | Schneider Electric | Quick Quote | |||
QO327M10060 Square D by Schneider Electric QO327M10060 is a load center designed for a rated current of 100A and a connection type utilizing lugs. It measures H758mm x W362mm (H29.84" x W14.25") and offers 27 spaces for single pole circuits. This load center is built with a welded sheet steel enclosure and tin-plated copper busbars, ensuring compatibility with a rated voltage of 120Vac/240Vac. It is equipped to handle a short circuit breaking rating of 25kA and is protected by a NEMA 1 degree of protection, making it suitable for various applications. | Schneider Electric | Quick Quote | |||
QO320L125RBI Square D by Schneider Electric QO320L125RBI is a load center designed to accommodate up to 20 single pole circuits. It features a neutral load center (LC) configuration with a rated current of 125A. The dimensions of this load center allow for 20 spaces, and it is constructed with a tin-plated copper busbar. It operates at a rated voltage of 120Vac/240Vac and has a short circuit breaking rating of 65kA. | Schneider Electric | Quick Quote |