Schneider Electric LC1DT80A3FE7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, ensuring a reliable installation. This 4-pole (4NO) contactor is designed to handle a rated current of 80A under AC-1 conditions and can be mounted on a DIN rail. The unit has a net width of 70 mm and offers a degree of protection rated at IP20. It operates within control voltage ranges of 92-126Vac at 50Hz and 98-126Vac at 60Hz, with a nominal voltage of 115Vac. The LC1DT80A3FE7 includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type, and is capable of withstanding a rated impulse voltage of 6 kV. Its mechanical durability is rated for 6 million operations at no load, and it can handle phase-to-phase rated voltages up to 690 V.
Quick Quote
Schneider Electric LC1DT80A3B7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals. It is designed with spring connections for control and screw connections for power, and it has 4 poles (4NO). This contactor is rated for 80A (AC-1), suitable for DIN rail mounting, and has a net width of 70 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) of 19.2-26.4Vac (24Vac nominal; 50Hz; 0.8...1.1 x Uc) or 20.4-26.4Vac (24Vac nominal; 60Hz; 0.85...1.1 x Uc). The LC1DT80A3B7 includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). It has a mechanical durability of 6 million operations at no load and can handle a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) phase-to-phase is up to 690 V.
Quick Quote
Schneider Electric LC1DT60AYC7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and is suitable for DIN rail mounting. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges from 528-726Vac at 50Hz (660Vac nominal; 0.8...1.1 x Uc) to 561-726Vac at 60Hz (660Vac nominal; 0.85...1.1 x Uc). It includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV, and it boasts a mechanical durability of 6,000,000 operations at no load. The rated voltage (AC) for phase-to-phase connections is up to 690 V.
Quick Quote
Schneider Electric LC1DT60AT7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges between 384-528Vac at 50Hz and 408-528Vac at 60Hz, with a nominal voltage of 480Vac. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The LC1DT60AT7 is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of up to 6 million operations at no load. Its rated voltage for AC phase-to-phase connections is up to 690 V.
Quick Quote
Schneider Electric LC1DT60AMD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for this device ranges from 165-275Vdc (220Vdc nominal; 0.75...1.25 x Uc), with a rated operating voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both types being instantaneous (1NO+1NC). The LC1DT60AMD is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and boasts a mechanical durability of 6 million operations at no load. The rated voltage for phase-to-phase connections is specified at 690 V.
Quick Quote
Schneider Electric LC1DT60AJD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for this device is specified at 9-15Vdc (12Vdc nominal; 0.75...1.25 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both rated at 1NO+1NC instantaneous aux. The LC1DT60AJD is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and boasts a mechanical durability of 6,000,000 operations at no load. The rated voltage (AC) for phase-to-phase connections is 690 V.
Quick Quote
Schneider Electric LC1DT60AFC7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges from 102-139Vac at 50Hz (127Vac nominal; 0.8...1.1 x Uc) to 108-139Vac at 60Hz (127Vac nominal; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The LC1DT60AFC7 is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. The rated voltage (AC) for phase-to-phase connections is up to 690 V.
Quick Quote
Schneider Electric LC1DT60A6G7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for secure connections. This contactor is equipped with ring-lugs connections and has a 4-pole (4P; 4NO) configuration. It is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. The unit has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 96-132Vac (120Vac nominal; 50Hz; 0.8...1.1 x Uc) to 102-132Vac (120Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The mechanical durability of the contactor is rated at 6,000,000 operations at no load, and it can operate at a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase connections is up to 690 V.
Quick Quote
Schneider Electric LC1DT60A6FD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and ring-lugs connections. This 4-pole (4P; 4NO) contactor is designed for a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 82.5-137.5Vdc, with a nominal value of 110Vdc, equivalent to 0.75...1.25 times the control voltage (Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). The LC1DT60A6FD is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. It is rated for a phase-to-phase voltage of up to 690 V AC.
Quick Quote
Schneider Electric LC1DT60A6BD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for this unit is DC, ranging from 18-30Vdc with a nominal voltage of 24Vdc (0.75...1.25 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The LC1DT60A6BD is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. It is designed to operate at a rated voltage (AC) of up to 690 V phase-to-phase.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
LC1DT80A3FE7 Schneider Electric LC1DT80A3FE7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for secure connections. It is equipped with spring connections for control and screw connections for power, ensuring a reliable installation. This 4-pole (4NO) contactor is designed to handle a rated current of 80A under AC-1 conditions and can be mounted on a DIN rail. The unit has a net width of 70 mm and offers a degree of protection rated at IP20. It operates within control voltage ranges of 92-126Vac at 50Hz and 98-126Vac at 60Hz, with a nominal voltage of 115Vac. The LC1DT80A3FE7 includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type, and is capable of withstanding a rated impulse voltage of 6 kV. Its mechanical durability is rated for 6 million operations at no load, and it can handle phase-to-phase rated voltages up to 690 V. | Schneider Electric | Quick Quote | |||
LC1DT80A3B7 Schneider Electric LC1DT80A3B7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals. It is designed with spring connections for control and screw connections for power, and it has 4 poles (4NO). This contactor is rated for 80A (AC-1), suitable for DIN rail mounting, and has a net width of 70 mm. It offers a degree of protection of IP20 and operates with a control voltage (AC) of 19.2-26.4Vac (24Vac nominal; 50Hz; 0.8...1.1 x Uc) or 20.4-26.4Vac (24Vac nominal; 60Hz; 0.85...1.1 x Uc). The LC1DT80A3B7 includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). It has a mechanical durability of 6 million operations at no load and can handle a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) phase-to-phase is up to 690 V. | Schneider Electric | Quick Quote | |||
LC1DT60AYC7 Schneider Electric LC1DT60AYC7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and is suitable for DIN rail mounting. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges from 528-726Vac at 50Hz (660Vac nominal; 0.8...1.1 x Uc) to 561-726Vac at 60Hz (660Vac nominal; 0.85...1.1 x Uc). It includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). The rated impulse voltage (Uimp) is 6 kV, and it boasts a mechanical durability of 6,000,000 operations at no load. The rated voltage (AC) for phase-to-phase connections is up to 690 V. | Schneider Electric | Quick Quote | |||
LC1DT60AT7 Schneider Electric LC1DT60AT7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges between 384-528Vac at 50Hz and 408-528Vac at 60Hz, with a nominal voltage of 480Vac. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The LC1DT60AT7 is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of up to 6 million operations at no load. Its rated voltage for AC phase-to-phase connections is up to 690 V. | Schneider Electric | Quick Quote | |||
LC1DT60AMD Schneider Electric LC1DT60AMD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for this device ranges from 165-275Vdc (220Vdc nominal; 0.75...1.25 x Uc), with a rated operating voltage (Ue) of up to 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both types being instantaneous (1NO+1NC). The LC1DT60AMD is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and boasts a mechanical durability of 6 million operations at no load. The rated voltage for phase-to-phase connections is specified at 690 V. | Schneider Electric | Quick Quote | |||
LC1DT60AJD Schneider Electric LC1DT60AJD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for this device is specified at 9-15Vdc (12Vdc nominal; 0.75...1.25 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both rated at 1NO+1NC instantaneous aux. The LC1DT60AJD is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and boasts a mechanical durability of 6,000,000 operations at no load. The rated voltage (AC) for phase-to-phase connections is 690 V. | Schneider Electric | Quick Quote | |||
LC1DT60AFC7 Schneider Electric LC1DT60AFC7 is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminal design and screw connections for secure installation. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for AC ranges from 102-139Vac at 50Hz (127Vac nominal; 0.8...1.1 x Uc) to 108-139Vac at 60Hz (127Vac nominal; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The LC1DT60AFC7 is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. The rated voltage (AC) for phase-to-phase connections is up to 690 V. | Schneider Electric | Quick Quote | |||
LC1DT60A6G7 Schneider Electric LC1DT60A6G7 is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for secure connections. This contactor is equipped with ring-lugs connections and has a 4-pole (4P; 4NO) configuration. It is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. The unit has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage (AC) ranges from 96-132Vac (120Vac nominal; 50Hz; 0.8...1.1 x Uc) to 102-132Vac (120Vac nominal; 60Hz; 0.85...1.1 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, with the contacts type being 1NO+1NC instantaneous auxiliaries. The mechanical durability of the contactor is rated at 6,000,000 operations at no load, and it can operate at a rated impulse voltage (Uimp) of 6 kV. The rated voltage (AC) for phase-to-phase connections is up to 690 V. | Schneider Electric | Quick Quote | |||
LC1DT60A6FD Schneider Electric LC1DT60A6FD is a magnetic contactor from the Deca sub-range, featuring EverLink(TM) terminals and ring-lugs connections. This 4-pole (4P; 4NO) contactor is designed for a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection of IP20. The control voltage (DC) ranges from 82.5-137.5Vdc, with a nominal value of 110Vdc, equivalent to 0.75...1.25 times the control voltage (Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contacts, both of the instantaneous type (1NO+1NC). The LC1DT60A6FD is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. It is rated for a phase-to-phase voltage of up to 690 V AC. | Schneider Electric | Quick Quote | |||
LC1DT60A6BD Schneider Electric LC1DT60A6BD is a magnetic contactor from the Deca sub-range, featuring an EverLink(TM) terminal design for ring-lugs connections. This 4-pole (4P; 4NO) contactor is designed to handle a rated current of 60A (AC-1) and can be mounted on a DIN rail. It has a net width of 70 mm and offers a degree of protection rated at IP20. The control voltage for this unit is DC, ranging from 18-30Vdc with a nominal voltage of 24Vdc (0.75...1.25 x Uc). It includes 1 Normally Open (NO) and 1 Normally Closed (NC) auxiliary contact, both of the instantaneous type (1NO+1NC). The LC1DT60A6BD is capable of withstanding a rated impulse voltage (Uimp) of 6 kV and has a mechanical durability of 6 million operations at no load. It is designed to operate at a rated voltage (AC) of up to 690 V phase-to-phase. | Schneider Electric | Quick Quote |