LC1F800QW Schneider Electric Electronic Components

LC1F800QW on Powermatic Associates
Schneider Electric

Part#:LC1F800QW

Manufacturer:Schneider Electric

Category:Electronic Components

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric LC1F800QW is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features a 3-pole (3P; 3NO) configuration and supports ring-lugs/bar connections. The contactor is rated for currents up to 1000A in AC-1 applications and 800A in 440Vac AC-3 applications. Control voltage specifications include 340-440Vdc (400Vdc nominal; 0.85...1.1 x Uc) for DC and 323-456Vac (380-415Vac nominal; 40-400Hz; 0.85...1.1 x Uc) for AC, with a rated operating voltage (Ue) of 1000 V. It does not include normally open (NO) or normally closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV, and it can handle rated active power ranging from 250kW at 220-230Vac to 475kW at 660-690Vac in AC-3 applications. Mechanical durability is specified at 5,000,000 operations at no load, and the rated voltage (AC) phase-to-phase is 1000 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Electronic Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1F800QW Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Motor Power Kw
    450 kW 1000 V AC 50/60 Hz AC-3) 450 kW 500 V AC 50/60 Hz AC-3) 475 kW 660...690 V AC 50/60 Hz AC-3) 110 kW 400 V AC 50/60 Hz AC-4) 450 kW 380...400 V AC 50/60 Hz AC-3) 450 kW 415 V AC 50/60 Hz AC-3) 450 kW 440 V AC 50/60 Hz A
  • Product Certifications
    UL CSA RMRoS CB ABS CCC UKCA
  • [Icw] Rated Short-Time Withstand Current
    5500 A 104 °F (40 °C) - 10 s 4600 A 104 °F (40 °C) - 30 s 3600 A 104 °F (40 °C) - 1 min 2600 A 104 °F (40 °C) - 3 min 1700 A 104 °F (40 °C) - 10 min
  • Standards
    JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 IEC 60947-1 EN 60947-1
  • Motor Power Range
    250…500 kW 200…240 V 3 phase 250…500 kW 380…440 V 3 phase 110…220 kW 200…240 V 3 phase 250…500 kW 480…500 V 3 phase
  • Contactor Coil Voltage
    400 V DC standard 400 V AC standard 380 V AC standard 415 V AC standard
  • Connections - Terminals
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
  • Utilisation Category
    AC-3 AC-1 AC-4
  • Tightening Torque
    Control circuit 10.62 lbf.in (1.2 N.m) Power circuit 513.34 lbf.in (58 N.m)
  • Control Circuit Voltage Limits
    Operational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
  • [Ui] Rated Insulation Voltage
    1000 V IEC 60947-4-1 1500 V VDE 0110 group C
  • Power Dissipation Per Pole
    120 W AC-1 77 W AC-3
  • Associated Fuse Rating
    1000 A gG <= 440 V 800 A aM <= 440 V
  • [Uc] Control Circuit Voltage
    400 V DC 380...415 V AC 40...400 Hz
  • Operating Time
    40...50 ms opening 60...80 ms closing
  • [Ue] Rated Operational Voltage
    <= 1000 V AC 50/60 Hz <= 460 V DC
  • Contactor Application
    Resistive load Motor control
  • [Ie] Rated Operational Current
    1000 A 104 °F (40 °C)) <= 440 V AC AC-1 800 A 131 °F (55 °C)) <= 440 V AC AC-3
  • Compatibility Code
    LC1F
  • Heat Dissipation
    12 W
  • Motor Starter Type
    Direct on-line contactor
  • Maximum Operating Rate
    600 cyc/h 55 °C
  • Mechanical Durability
    5 Mcycles
  • Hold-In Power Consumption In W
    12 W 68 °F (20 °C)
  • Inrush Power In W
    1900 W 68 °F (20 °C))
  • Mounting Support
    Plate
  • Average Impedance
    0.12 mOhm - Ith 1000 A 50 Hz
  • Coil Type
    Standard
  • Rated Breaking Capacity
    6400 A IEC 60947-4-1
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV
  • [Ith] Conventional Free Air Thermal Current
    1000 A 104 °F (40 °C)
  • Overvoltage Category
    III
  • Range
    TeSys
  • Device Short Name
    LC1F
  • Power Pole Contact Composition
    3 NO
  • Product Or Component Type
    Contactor
  • Poles Description
    3P
  • Product Name
    TeSys F

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Manufacturer warranty

$6,676.00

Request a quote, and we will send availability within minutes.

Select Qty:

$6,676.00

$6,676.00 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!