Schneider Electric LC1F225M7 Schneider Electric LC1F225M7 is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features ring-lugs/bar connections and is equipped with 3 poles (3P; 3NO). The contactor is rated for currents of 315A under AC-1 conditions and 225A at 440Vac under AC-3 conditions. The control voltage (AC) specifications are 187-242Vac (220Vac nominal; 40-400Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. It has 0 Normally Open (NO) auxiliary contacts and 0 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV. The rated active power (kW) varies with voltage: 63kW at 220-230Vac, 110kW at 380-400Vac, 415Vac, and 440Vac, 129kW at 500Vac and 660-690Vac, and 100kW at 1000Vac, all under AC-3 conditions. Its mechanical durability is rated at 10,000,000 operations at no load, and the rated voltage (AC) phase-to-phase is 1000 V.
Schneider Electric

Part#:LC1F225M7

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric LC1F225M7 is a high-power magnetic contactor within the F sub-range, designed for surface mounting. It features ring-lugs/bar connections and is equipped with 3 poles (3P; 3NO). The contactor is rated for currents of 315A under AC-1 conditions and 225A at 440Vac under AC-3 conditions. The control voltage (AC) specifications are 187-242Vac (220Vac nominal; 40-400Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 1000 V. It has 0 Normally Open (NO) auxiliary contacts and 0 Normally Closed (NC) auxiliary contacts. The rated impulse voltage (Uimp) is 8 kV. The rated active power (kW) varies with voltage: 63kW at 220-230Vac, 110kW at 380-400Vac, 415Vac, and 440Vac, 129kW at 500Vac and 660-690Vac, and 100kW at 1000Vac, all under AC-3 conditions. Its mechanical durability is rated at 10,000,000 operations at no load, and the rated voltage (AC) phase-to-phase is 1000 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Electronic Components that you can order at Powermatic Associates site. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1F225M7 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Product Certifications
    RINA BV CSA UL LROS (Lloyds register of shipping) DNV RMRoS ABS CB UKCA
  • Motor Power Kw
    110 kW 380...400 V AC 50/60 Hz AC-3) 110 kW 415 V AC 50/60 Hz AC-3) 110 kW 440 V AC 50/60 Hz AC-3) 129 kW 500 V AC 50/60 Hz AC-3) 129 kW 660...690 V AC 50/60 Hz AC-3) 63 kW 220...230 V AC 50/60 Hz AC-3) 40 kW 400 V AC 50/60 H
  • [Icw] Rated Short-Time Withstand Current
    1800 A 104 °F (40 °C) - 10 s 1000 A 104 °F (40 °C) - 30 s 850 A 104 °F (40 °C) - 1 min 560 A 104 °F (40 °C) - 3 min 440 A 104 °F (40 °C) - 10 min
  • Standards
    IEC 60947-1 JIS C8201-4-1 EN 60947-1 IEC 60947-4-1 EN 60947-4-1
  • Connections - Terminals
    Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)fl
  • Motor Power Range
    55…100 kW 200…240 V 3 phase 110…220 kW 480…500 V 3 phase 110…220 kW 380…440 V 3 phase
  • Utilisation Category
    AC-1 AC-4 AC-3
  • Operating Time
    35 ms closing at Uc) 130 ms opening at Uc)
  • [Ui] Rated Insulation Voltage
    1000 V IEC 60947-4-1 1500 V VDE 0110 group C
  • Power Dissipation Per Pole
    32 W AC-1 16 W AC-3
  • Associated Fuse Rating
    315 A gG <= 440 V 250 A aM <= 440 V
  • Control Circuit Voltage Limits
    Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 40...400 Hz 131 °F (55 °C))
  • Contactor Application
    Motor control Resistive load
  • Tightening Torque
    Control circuit 10.62 lbf.in (1.2 N.m) Power circuit 309.78 lbf.in (35 N.m)
  • [Ue] Rated Operational Voltage
    <= 460 V DC <= 690 V AC 50/60 Hz
  • [Ie] Rated Operational Current
    315 A 104 °F (40 °C)) <= 440 V AC-1 225 A 131 °F (55 °C)) <= 440 V AC-3
  • Contactor Coil Voltage
    220 V AC standard
  • Hold-In Power Consumption In VA
    9.9 VA 40...400 Hz 0.9 68 °F (20 °C))
  • Motor Starter Type
    Direct on-line contactor
  • Compatibility Code
    LC1F
  • Maximum Operating Rate
    2400 cyc/h 131 °F (55 °C)
  • Mechanical Durability
    10 Mcycles
  • Heat Dissipation
    8…9.8 W
  • Inrush Power In VA
    1070 VA 40...400 Hz 0.9 68 °F (20 °C))
  • Mounting Support
    Plate
  • Average Impedance
    0.32 mOhm - Ith 315 A 50 Hz
  • Rated Breaking Capacity
    1800 A IEC 60947-4-1
  • [Ith] Conventional Free Air Thermal Current
    315 A 104 °F (40 °C)
  • Overvoltage Category
    III
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV
  • [Uc] Control Circuit Voltage
    220 V AC 40...400 Hz
  • Power Pole Contact Composition
    3 NO
  • Poles Description
    3P
  • Device Short Name
    LC1F
  • Product Or Component Type
    Contactor
  • Product Name
    TeSys F
  • Range
    TeSys

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.



Manufacturer warranty

$1,059.00

Request a quote, and we will send availability within minutes.

Select Qty:

$1,059.00

$1,059.00 each

Average response time: 11 minutes

Worldwide Shipping and Delivery


Secure Payment Processing


Warranty


Responsive Customer Support

Got Questions? We've Got Answers!


Need more details?

Feel free to chat with us

Relevant products

CP5.241 Part Image. Manufactured by Puls.

CP5.241

Verified stock: 4

PULS CP5.241 is a power supply unit designed for DIN rail mounting with a net width of 32 mm and an aluminium housing. It operates within an ambient air temperature range of -25 to +70°C. The unit features a current consumption of 7A peak max. inrush at both 230Vac and 120Vac inputs. Its efficiency rates are 0.943 at 230Vac input, 0.935 at 120Vac input, and 0.927 at 100Vac input. The dimensions of the CP5.241 are W32mm x H124mm x D102mm. It has a start-up delay of 380-420ms for 100-230Vac input, with rise times of 80ms and 100ms under nominal input with constant full current load at 0mF and 5mF load capacitance, respectively. The unit includes protection functions such as output overvoltage protection and overload/short-circuit protection, with the capability for series or parallel operation for increased output voltages or power. It is resistant to back-feeding loads up to 35V. Power dissipation/losses are 7.3 W at 230Vac input and 8.2 W at 120Vac input with full output load. The output stage capacitance is 1800 µF. Electrical durability varies with conditions, reaching up to 775000 hours at 25°C and 2.5A output with 1AC 230Vac input. The ripple is 50mVpp across 20Hz to 20MHz at 50Ω. This AC/DC power supply unit, part of the CP-series, is designed with a 20% power reserve and includes a DC-OK relay contact output. It features screw-clamp connections and supports a supply voltage range of 85Vac-264Vac for AC and 110Vdc-180Vdc for DC, with a rated current of 5A at 24Vdc. The output voltage is adjustable between 24Vdc and 28Vdc, with a 200mV turn-ON overshoot and a hold time of 35ms at 120/230Vac input.

Puls

What can I help you find today?

Recommended parts

UBC10.241

UBC10.241

PULS UBC10.241 is an Uninterruptible Power Supply (UPS) control module within the U-series, featuring a built-in battery with a 50% power reserve and a green status LED. This module is housed in aluminium and utilizes spring-clamp connections for installation. It measures W123mm x H124mm x D119mm and operates on a supply voltage range of 22.5Vdc to 30Vdc, with a nominal 24Vdc. The rated current is 10A at 22.5Vdc and can reach up to 15A in buffer mode for less than 5 seconds at full output voltage. It supports DIN rail mounting and can operate in ambient air temperatures ranging from 0 to +40°C. The current consumption is 1.1A at a 24Vdc input, and it is designed for DC networks. Visual position indicators include Ready, Buffering, Inhibit, and Replace Battery. Protection functions include output overvoltage protection with a typical 32Vdc and a maximum of 35Vdc, and overload/short-circuit protection with a minimum of 17.9A and a maximum of 21A at load impedance. It is advised not to use the DC-UPS in parallel to increase output power, but paralleling two units for 1+1 redundancy is possible for higher system reliability. The output voltage is regulated at 22.5Vdc in buffer mode with a 23Vdc turn-ON. The efficiency is rated at 0.978 with a 24Vdc input, and the rated power is 360W at 24Vdc and 240W/360W in buffer mode. Power dissipation/losses are 2.9W with a 24Vdc input at 0A output current and 5.5W at 10A output current. Ripple is maintained at 20mVpp across a frequency range of 20Hz to 20MHz at 50Ω. The electrical durability is rated at 137400 hours at 40°C with a 10A output and 24Vdc input, equivalent to 15 years or 131400 hours at both 40°C with a 5A output and 25°C with a 10A output.