BDL36125

Schneider Electric

Product Lifecycle: Active

Circuit breaker, PowerPacT B, 125A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%

BDL36125

Circuit breaker, PowerPacT B, 125A, 3 pole, 600Y/347VAC, 14kA, lugs, thermal magnetic, 80%

  • Breaking Capacity25 kA 208Y/120 V AC 50/60 Hz UL 489 25 kA 240 V AC 50/60 Hz UL 489 18 kA 480/277 V AC 50/60 Hz UL 489 18 kA 480 V AC 50/60 Hz UL 489 14 kA 600Y/347 V AC 50/60 Hz UL 489 10 kA 250 V DC UL 489
  • [Ics] Rated Service Breaking Capacity25 kA 220...240 V AC 50/60 Hz IEC 60947-2 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 18 kA 440 V AC 50/60 Hz IEC 60947-2
  • Number Of Slots1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in) 1 alarm switch SD plug-in)
  • Mounting ModeClip-on 35 x 15 mm symmetrical DIN rail) By screws plate)
  • Tightening Torque44.25 lbf.in (5 N.m) 0.00…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.66 lbf.in (9 N.m) 0.04…0.15 in² (25…95 mm²) (AWG 3...AWG 3/0)
  • Electrical ConnectionEverlink lug line Everlink lug load
  • AWG GaugeAWG 6...AWG 2/0 fine stranded aluminium/copper AWG 14...AWG 3/0 rigid or stranded aluminium/copper
  • Net Weight2.37 lb(US) (1.074 kg)
  • 9 Mm Pitches9
  • Trip Unit TechnologyThermal-magnetic
  • Quantity Per SetSet of 1
  • ColorGrey (RAL 7016)
  • Power Wire Stripping Length0.79 in (20 mm)
  • Depth3.15 in (80 mm)
  • Height5.39 in (137 mm)
  • Width3.19 in (81 mm)
  • Connection Pitch1.06 in (27 mm)
  • Electrical Durability10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
  • Local Signallingfor presence of auxiliary contacts flag (green)
  • [Ui] Rated Insulation Voltage800 V IEC 60947-2
  • Continuous Current Rating80 %
  • [Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947-2
  • Mechanical Durability20000 cycles IEC 947-1 Annex K ed 5.2
  • Utilisation CategoryCategory A
  • Suitability For IsolationYes IEC 60947-2
  • Breaking Capacity CodeD
  • Control TypeToggle
  • [Ue] Rated Operational Voltage525 V AC 50/60 Hz UL 489
  • Number Of Poles3P
  • Line Rated Current125 A
  • Device ApplicationDistribution
  • Product NamePowerPact B
  • Product Or Component TypeCircuit breaker
  • Device Short NameBD 125
  • RangePowerPact
This part can ship within 24 hours
Support Agent Icon

$1,828.86

Stock:

4

Select Qty:

$1,828.86

$1,828.86 each

This part can ship within 24h!

Fast worldwide Shipping and Delivery

Shipping cost will be calculated during checkout


Payments methods

Secure Payment Processing
with money back guarantee

1 year warranty on all parts


Responsive Customer Support
with personalized assistance


Need more details?

Feel free to chat with us.

Relevant products

This item can ship within 24h!

BDL36020

BDL36020

Square D by Schneider Electric BDL36020 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDL sub-range, featuring a PowerPact B-Frame 100 TMD 3P 20A design for 600Y/347Vac with a 14kA breaking capacity and 80% rated Everlink (Creep compensating) lugs on both line and load sides. It has a rated impulse voltage (Uimp) of 8 kV and offers a degree of protection of IP40. The rated current is 20A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB has a mechanical durability of 20,000 operations when not under load and can be mounted either on a DIN rail or as an individual unit on a plate. It features 3 poles (3P) and has dimensions of 137 mm in height, 80 mm in depth, and 81 mm in width. The utilisation category is A. Protection settings include over-current fixed at 20A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions encompass thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 20 AT. Its electrical durability with load is rated at 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies by voltage: 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider ElectricSTOCK: 2
Friendly Powermatic robot

What can I help you find today?