Turck
Turck

Found 236 products

IM12-DI03-1S-2R-S/24VDC/CC
Turck

Isolating switching amplifier, 1-channel, , Relay output (changeover contact), Alarm output (changeover contact), Switchable between: Alarm output or signal doubling, Output mode adjustable (open-circuit/closed current mode), Input circuits monitored for wire break/short circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2

Quick Quote

IMX12-DI03-1S-2T-S/24VDC/CC
Turck

Isolating switching amplifier, 1-channel, , Transistor output (≤10 kHz), Switchable: Alarm output or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2

Quick Quote

IM1-12EX-MT
Turck

Isolating switching amplifier, 1-channel, , 2 transistor outputs (MOSFET), Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, cUL, cFM, CSA, TR CU, NEPSI, KOSHA, CCOE, INMETRO, Installation in zone 2

Quick Quote

IM1-121EX-T
Turck

Isolating switching amplifier, 1-channel, , 2 transistor outputs, short-circuit proof, potential-free and reverse-polarity protected, Common alarm output, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), SIL 2, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, cUL, cFM, CSA, TR CU, NEPSI, KOSHA, TIIS, CCOE, INMETRO, Installation in zone 2

Quick Quote

IMX12-DO01-1U-1U-PR/24VDC
Turck

Solenoid Driver, 1-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2

Quick Quote

IM12-FI01-1SF-1I1R-CPR/24VDC/CC
Turck

Frequency Transducer/Pulse Counter, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2

Quick Quote

IM12-DI03-1S-2T-S/24VDC
Turck

Isolating switching amplifier, 1-channel, , Transistor output (≤ 10 kHz), Transistor alarm output, Switchable between: Alarm output or signal doubling, Output mode adjustable (open-circuit/closed current mode), Input circuits monitored for wire break/short circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2

Quick Quote

IM12-FI01-2SF-2I-CPR/24VDC/CC
Turck

Frequency Transducer/Pulse Counter, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2

Quick Quote

IMX12-FI01-2SF-2I-C0/24VDC
Turck

Frequency Transducer/Pulse Counter, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Output circuits monitored for wire break and short circuit, ATEX, IECEx, cFM, cUL, NEPSI, INMETRO, KOSHA, TR CU EAC CMI, TIIS, Installation in zone 2, SIL 2

Quick Quote

IMX12-DO01-1U-1U-0/24VDC
Turck

Solenoid Driver, 1-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2

Quick Quote

ItemManufacturerPriceStockDelivery
IM12-DI03-1S-2R-S/24VDC/CC

IM12-DI03-1S-2R-S/24VDC/CC

Isolating switching amplifier, 1-channel, , Relay output (changeover contact), Alarm output (changeover contact), Switchable between: Alarm output or signal doubling, Output mode adjustable (open-circuit/closed current mode), Input circuits monitored for wire break/short circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX use in Zone 2, cUL, SIL 2

Turck

Quick Quote

IMX12-DI03-1S-2T-S/24VDC/CC

IMX12-DI03-1S-2T-S/24VDC/CC

Isolating switching amplifier, 1-channel, , Transistor output (≤10 kHz), Switchable: Alarm output or signal doubling, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable spring type terminals, ATEX, IECEx, NEPSI, cUL, cFM, INMETRO, KOSHA, TIIS, TR CU EAC, Installation in zone 2, SIL 2

Turck

Quick Quote

IM1-12EX-MT

IM1-12EX-MT

Isolating switching amplifier, 1-channel, , 2 transistor outputs (MOSFET), Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break and short-circuit, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, cUL, cFM, CSA, TR CU, NEPSI, KOSHA, CCOE, INMETRO, Installation in zone 2

Turck

Quick Quote

IM1-121EX-T

IM1-121EX-T

Isolating switching amplifier, 1-channel, , 2 transistor outputs, short-circuit proof, potential-free and reverse-polarity protected, Common alarm output, Output mode adjustable (NO/NC mode), Input circuits monitored for wire-break/short-circuit (ON/OFF switchable), SIL 2, Complete galvanic isolation, Input reverse-polarity protected, ATEX, IECEx, cUL, cFM, CSA, TR CU, NEPSI, KOSHA, TIIS, CCOE, INMETRO, Installation in zone 2

Turck

Quick Quote

IMX12-DO01-1U-1U-PR/24VDC

IMX12-DO01-1U-1U-PR/24VDC

Solenoid Driver, 1-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, Power bridge (connector incl. in delivery), ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2

Turck

Quick Quote

IM12-FI01-1SF-1I1R-CPR/24VDC/CC

IM12-FI01-1SF-1I1R-CPR/24VDC/CC

Frequency Transducer/Pulse Counter, 1-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2

Turck

Quick Quote

IM12-DI03-1S-2T-S/24VDC

IM12-DI03-1S-2T-S/24VDC

Isolating switching amplifier, 1-channel, , Transistor output (≤ 10 kHz), Transistor alarm output, Switchable between: Alarm output or signal doubling, Output mode adjustable (open-circuit/closed current mode), Input circuits monitored for wire break/short circuit (ON/OFF switchable), Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX use in Zone 2, cUL, SIL 2

Turck

Quick Quote

IM12-FI01-2SF-2I-CPR/24VDC/CC

IM12-FI01-2SF-2I-CPR/24VDC/CC

Frequency Transducer/Pulse Counter, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Removable spring type terminals, Power bridge (connector incl. in delivery), ATEX use in Zone 2, cUL, SIL 2

Turck

Quick Quote

IMX12-FI01-2SF-2I-C0/24VDC

IMX12-FI01-2SF-2I-C0/24VDC

Frequency Transducer/Pulse Counter, 2-channel, , Input circuits monitored for wire-break and short-circuit, Parameterized via PC, Complete galvanic isolation, Input reverse-polarity protected, Output circuits monitored for wire break and short circuit, ATEX, IECEx, cFM, cUL, NEPSI, INMETRO, KOSHA, TR CU EAC CMI, TIIS, Installation in zone 2, SIL 2

Turck

Quick Quote

IMX12-DO01-1U-1U-0/24VDC

IMX12-DO01-1U-1U-0/24VDC

Solenoid Driver, 1-channel, , Output circuits monitored for wire-break and short-circuit, , Complete galvanic isolation, Input reverse-polarity protected, Removable screw terminals, ATEX, IECEx, cUL, cFM, INMETRO, NEPSI, Kosha, TR CU EAC, TIIS, Installation in zone 2, SIL 2

Turck

Quick Quote