Telemecanique XCSDMP7002 is a safety switch from the XCSDM sub-range, designed as a coded magnetic switch for confirming the closure of doors, hoods, or covers with a sensing approach distance (Sao) of 10mm and a sensing release distance (Sar) of 20mm. It features 1NC staggered and 1 NO auxiliary contacts, encapsulated in a thermoplastic case with a PVC cable, ensuring a connection type that is pre-cabled. This switch is characterized by a 3 Pole configuration and offers a degree of protection rated at IP66 and IP67, making it suitable for demanding environments. The cable length is 2 meters, and it operates with a rated insulation voltage (Ui) of 100 V. It includes 2 NC auxiliary contacts and supports a control circuit rated current of 100mA / 0.1 A at 24Vdc (DC-13). The XCSDMP7002 is designed to function within a temperature range of -25°C to 70°C and boasts an electrical durability of 1,200,000 operations under load, with a rated impulse voltage (Uimp) of 2.5 kV.
Quick Quote
Telemecanique XCSDMP5005 is a coded magnetic safety switch designed for confirming the closure of doors, hoods, or covers. Part of the XCSDM sub-range, it features a Sao of 10mm and Sar of 20mm, with 1NO staggered configuration. This switch has a rated impulse voltage (Uimp) of 2.5 kV and is constructed from thermoplastic for the case and polyvinyl chloride (PVC) for the 5m pre-cabled connection, ensuring a degree of protection rated at IP66 and IP67. It is equipped with 3 poles, including 2 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated insulation voltage (Ui) stands at 100 V, and the control circuit rated current is 100mA / 0.1 A at 24Vdc (DC-13). This switch operates within a temperature range of -25°C to 70°C and boasts an electrical durability of 1,200,000 operations.
Quick Quote
Telemecanique XCSDMC7902 is a coded magnetic safety switch designed for confirming the closure of doors, hoods, or covers. It is part of the XCSDM sub-range and features a staggered operation with a sensing approach distance (Sao) of 10mm and a sensing release distance (Sar) of 20mm. The switch has a rated impulse voltage (Uimp) of 2.5 kV and is constructed from thermoplastic for the case and polyvinyl chloride (PVC) for the 2-meter pre-cabled connection, ensuring a degree of protection rated at IP66 and IP67. It is equipped with 2 poles and 2 normally closed (NC) auxiliary contacts. The control circuit is rated for a current of 100mA / 0.1 A at 24Vdc (DC-13). This safety switch can operate within a temperature range of -25°C to 70°C and has an electrical durability of 1,200,000 operations at rated load.
Quick Quote
Telemecanique XZCP0941L2 is a cable within the XCSDM sub-range, featuring a female M8 connector for connection. This straight-shaped cable comes with a 4-pin configuration and offers a degree of protection rated at IP67. It has a length of 2 meters.
Quick Quote
Telemecanique XZCP1041L2 is a cable within the XCSDM sub-range, featuring a female M8 connector with an elbowed shape for connection. It is equipped with a 4-pin configuration and offers a degree of protection rated at IP67. The cable length is 2 meters.
Quick Quote
Telemecanique XCSLF3737312 is a safety lock designed for door, cover, and hood safety guard interlock applications, featuring limit switch locking on de-energization and unlocking on energization with a break before make/slow break function. It has a rated impulse voltage (Uimp) of 4 kV and is constructed from Zamak for both the head and body. This part offers three M20 cable entries for connection, boasts an IP67 degree of protection, and has a mechanical durability of 1,000,000 operations at no load. It operates with 3 poles and supports control voltages of 24/48 Vac and 24/48 Vdc. The XCSLF3737312 includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a rated insulation voltage (Ui) of 250 V (UL) 300 V. It features an orange LED for guard opening and a green LED for guard locking indication. The control circuit rated current is 0.75 A for 240Vac (AC-15) and 100mA / 0.1 A for 250Vdc (DC-13), with similar ratings for 240Vac (C300) and 250Vdc (R300). This safety lock can operate within a temperature range of -25 °C to 70 °C, has an electrical durability of 1,000,000 operations with load at 240Vac/250Vdc, and utilizes solenoid locking (2NC+1NO break before make contact) for latching.
Quick Quote
Telemecanique XZCP1041L10 is a cable within the XCSDM sub-range featuring a female M8 connector with an elbowed shape. It is equipped with a 4-pin connection type and offers a degree of protection rated at IP67. The cable has a length of 10 meters.
Quick Quote
Telemecanique XZCP1041L5 is a cable within the XCSDM sub-range, featuring a female M8 connector with an elbowed shape for connection. It is equipped with a 4-pin M8 connector and offers a degree of protection rated at IP67. The cable has a length of 5 meters.
Quick Quote
Telemecanique XZCP29P11L5 is a cable designed for automation applications, featuring a female M12 connector within the XCSDM sub-range. This straight-shaped cable comes with an M12 connector type and is equipped with an 8-pin configuration. It offers a degree of protection rated at IP67, ensuring its suitability for environments where dust and water resistance are necessary. The cable has a length of 5 meters, accommodating installations that require a moderate distance between components.
Quick Quote
Telemecanique XCSLE3737312 is a safety lock designed for door, cover, and hood safety guard interlock applications, featuring limit switch locking on de-energization and unlocking on energization with a break before make/slow break function. It has a rated impulse voltage (Uimp) of 4 kV and is constructed with plastic materials for both the head and body. This part offers three M20 cable entries for connection, and it is protected to IP66 and IP67 standards. It is capable of enduring 1,000,000 mechanical operations at no load and has 3 poles. The control voltage is compatible with both 24 Vac and 24 Vdc systems. It includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a rated insulation voltage (Ui) of 250 V (UL) and 300 V. The visual position indicator features an orange LED for guard opening and a green LED for guard locking. The control circuit rated current is 0.75 A for 240Vac (AC-15) and 100mA / 0.1 A for 250Vdc (DC-13), with similar ratings for other specified conditions. It operates within a temperature range of -25 °C to 70 °C and has an electrical durability of 1,000,000 operations with load at 240Vac/250Vdc. The latching type is solenoid locking with 2NC+1NO break before make contact.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
XCSDMP7002 Telemecanique XCSDMP7002 is a safety switch from the XCSDM sub-range, designed as a coded magnetic switch for confirming the closure of doors, hoods, or covers with a sensing approach distance (Sao) of 10mm and a sensing release distance (Sar) of 20mm. It features 1NC staggered and 1 NO auxiliary contacts, encapsulated in a thermoplastic case with a PVC cable, ensuring a connection type that is pre-cabled. This switch is characterized by a 3 Pole configuration and offers a degree of protection rated at IP66 and IP67, making it suitable for demanding environments. The cable length is 2 meters, and it operates with a rated insulation voltage (Ui) of 100 V. It includes 2 NC auxiliary contacts and supports a control circuit rated current of 100mA / 0.1 A at 24Vdc (DC-13). The XCSDMP7002 is designed to function within a temperature range of -25°C to 70°C and boasts an electrical durability of 1,200,000 operations under load, with a rated impulse voltage (Uimp) of 2.5 kV. | Telemecanique Sensors | Quick Quote | |||
XCSDMP5005 Telemecanique XCSDMP5005 is a coded magnetic safety switch designed for confirming the closure of doors, hoods, or covers. Part of the XCSDM sub-range, it features a Sao of 10mm and Sar of 20mm, with 1NO staggered configuration. This switch has a rated impulse voltage (Uimp) of 2.5 kV and is constructed from thermoplastic for the case and polyvinyl chloride (PVC) for the 5m pre-cabled connection, ensuring a degree of protection rated at IP66 and IP67. It is equipped with 3 poles, including 2 normally open (NO) auxiliary contacts and 1 normally closed (NC) auxiliary contact. The rated insulation voltage (Ui) stands at 100 V, and the control circuit rated current is 100mA / 0.1 A at 24Vdc (DC-13). This switch operates within a temperature range of -25°C to 70°C and boasts an electrical durability of 1,200,000 operations. | Telemecanique Sensors | Quick Quote | |||
XCSDMC7902 Telemecanique XCSDMC7902 is a coded magnetic safety switch designed for confirming the closure of doors, hoods, or covers. It is part of the XCSDM sub-range and features a staggered operation with a sensing approach distance (Sao) of 10mm and a sensing release distance (Sar) of 20mm. The switch has a rated impulse voltage (Uimp) of 2.5 kV and is constructed from thermoplastic for the case and polyvinyl chloride (PVC) for the 2-meter pre-cabled connection, ensuring a degree of protection rated at IP66 and IP67. It is equipped with 2 poles and 2 normally closed (NC) auxiliary contacts. The control circuit is rated for a current of 100mA / 0.1 A at 24Vdc (DC-13). This safety switch can operate within a temperature range of -25°C to 70°C and has an electrical durability of 1,200,000 operations at rated load. | Telemecanique Sensors | Quick Quote | |||
XZCP0941L2 Telemecanique XZCP0941L2 is a cable within the XCSDM sub-range, featuring a female M8 connector for connection. This straight-shaped cable comes with a 4-pin configuration and offers a degree of protection rated at IP67. It has a length of 2 meters. | Telemecanique Sensors | Quick Quote | |||
XZCP1041L2 Telemecanique XZCP1041L2 is a cable within the XCSDM sub-range, featuring a female M8 connector with an elbowed shape for connection. It is equipped with a 4-pin configuration and offers a degree of protection rated at IP67. The cable length is 2 meters. | Telemecanique Sensors | Quick Quote | |||
XCSLF3737312 Telemecanique XCSLF3737312 is a safety lock designed for door, cover, and hood safety guard interlock applications, featuring limit switch locking on de-energization and unlocking on energization with a break before make/slow break function. It has a rated impulse voltage (Uimp) of 4 kV and is constructed from Zamak for both the head and body. This part offers three M20 cable entries for connection, boasts an IP67 degree of protection, and has a mechanical durability of 1,000,000 operations at no load. It operates with 3 poles and supports control voltages of 24/48 Vac and 24/48 Vdc. The XCSLF3737312 includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a rated insulation voltage (Ui) of 250 V (UL) 300 V. It features an orange LED for guard opening and a green LED for guard locking indication. The control circuit rated current is 0.75 A for 240Vac (AC-15) and 100mA / 0.1 A for 250Vdc (DC-13), with similar ratings for 240Vac (C300) and 250Vdc (R300). This safety lock can operate within a temperature range of -25 °C to 70 °C, has an electrical durability of 1,000,000 operations with load at 240Vac/250Vdc, and utilizes solenoid locking (2NC+1NO break before make contact) for latching. | Telemecanique Sensors | Quick Quote | |||
XZCP1041L10 Telemecanique XZCP1041L10 is a cable within the XCSDM sub-range featuring a female M8 connector with an elbowed shape. It is equipped with a 4-pin connection type and offers a degree of protection rated at IP67. The cable has a length of 10 meters. | Telemecanique Sensors | Quick Quote | |||
XZCP1041L5 Telemecanique XZCP1041L5 is a cable within the XCSDM sub-range, featuring a female M8 connector with an elbowed shape for connection. It is equipped with a 4-pin M8 connector and offers a degree of protection rated at IP67. The cable has a length of 5 meters. | Telemecanique Sensors | Quick Quote | |||
XZCP29P11L5 Telemecanique XZCP29P11L5 is a cable designed for automation applications, featuring a female M12 connector within the XCSDM sub-range. This straight-shaped cable comes with an M12 connector type and is equipped with an 8-pin configuration. It offers a degree of protection rated at IP67, ensuring its suitability for environments where dust and water resistance are necessary. The cable has a length of 5 meters, accommodating installations that require a moderate distance between components. | Telemecanique Sensors | Quick Quote | |||
XCSLE3737312 Telemecanique XCSLE3737312 is a safety lock designed for door, cover, and hood safety guard interlock applications, featuring limit switch locking on de-energization and unlocking on energization with a break before make/slow break function. It has a rated impulse voltage (Uimp) of 4 kV and is constructed with plastic materials for both the head and body. This part offers three M20 cable entries for connection, and it is protected to IP66 and IP67 standards. It is capable of enduring 1,000,000 mechanical operations at no load and has 3 poles. The control voltage is compatible with both 24 Vac and 24 Vdc systems. It includes 1 Normally Open (NO) auxiliary contact and 2 Normally Closed (NC) auxiliary contacts, with a rated insulation voltage (Ui) of 250 V (UL) and 300 V. The visual position indicator features an orange LED for guard opening and a green LED for guard locking. The control circuit rated current is 0.75 A for 240Vac (AC-15) and 100mA / 0.1 A for 250Vdc (DC-13), with similar ratings for other specified conditions. It operates within a temperature range of -25 °C to 70 °C and has an electrical durability of 1,000,000 operations with load at 240Vac/250Vdc. The latching type is solenoid locking with 2NC+1NO break before make contact. | Telemecanique Sensors | Quick Quote |