All categories

Industrial Automation Components

Manufacturer
NK Technologies
NK Technologies

Found 1,048 products

AG3-NCR1-24U-LA-TR3
NK Technologies

AC Ground Fault Sensors, Mechanical Relay Output, Solid-Core, 24 VAC/VDC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Latching, Top Terminals, N.C. 1 A @ 120 VAC, 2 A @ 30 VDC

Quick Quote

AS1-NCU-FT
NK Technologies

NK Technologies - AS1-NCU-FT

Quick Quote

AG3-NCDC-24U-FS-TR3
NK Technologies

AC Ground Fault Sensors, Solid State Output, Solid-Core, 24 VAC/VDC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Normally Energized, Top Terminals, N.C. 0.15 A @ 30 VDC

Quick Quote

AG3-NCR1-120-LA-TR3
NK Technologies

AC Ground Fault Sensors, Mechanical Relay Output, Solid-Core, 120 VAC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Latching, Top Terminals, N.C. 1 A @ 120 VAC, 2 A @ 30 VDC

Quick Quote

AG3-SDT1-120-DEN-TR3
NK Technologies

AC Ground Fault Sensors, Mechanical Relay Output, Solid-Core, 120 VAC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Normally De-Energized, Top Terminals, SPDT 1 A @ 120 VAC, 2 A @ 30 VDC

Quick Quote

AGL1-SDT1-24U-DEN-60
NK Technologies

Ground fault sensor with SPDT Relay output, Normally De-energized, Auto Reset, 24VAC/DC power supply, 60mA setpoin

Quick Quote

ASXP2-SDT-120-FL
NK Technologies

NK Technologies - ASXP2-SDT-120-FL

Quick Quote

ASXP8-SDT-24U-MS
NK Technologies

NK Technologies - ASXP8-SDT-24U-MS

Quick Quote

AG3-NCAC-24U-NF-TR3
NK Technologies

AC Ground Fault Sensors, Solid State Output, Solid-Core, 24 VAC/VDC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Normally De-Energized, Top Terminals, N.C. 1 A @ 240 VAC

Quick Quote

AG3-NCDC-120-NF-TR3
NK Technologies

AC Ground Fault Sensors, Solid State Output, Solid-Core, 120 VAC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Normally De-Energized, Top Terminals, N.C. 0.15 A @ 30 VDC

Quick Quote

ItemManufacturerPriceStockDelivery
AG3-NCR1-24U-LA-TR3

AG3-NCR1-24U-LA-TR3

AC Ground Fault Sensors, Mechanical Relay Output, Solid-Core, 24 VAC/VDC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Latching, Top Terminals, N.C. 1 A @ 120 VAC, 2 A @ 30 VDC

NK Technologies

Quick Quote

AS1-NCU-FT

AS1-NCU-FT

NK Technologies - AS1-NCU-FT

NK Technologies

Quick Quote

AG3-NCDC-24U-FS-TR3

AG3-NCDC-24U-FS-TR3

AC Ground Fault Sensors, Solid State Output, Solid-Core, 24 VAC/VDC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Normally Energized, Top Terminals, N.C. 0.15 A @ 30 VDC

NK Technologies

Quick Quote

AG3-NCR1-120-LA-TR3

AG3-NCR1-120-LA-TR3

AC Ground Fault Sensors, Mechanical Relay Output, Solid-Core, 120 VAC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Latching, Top Terminals, N.C. 1 A @ 120 VAC, 2 A @ 30 VDC

NK Technologies

Quick Quote

AG3-SDT1-120-DEN-TR3

AG3-SDT1-120-DEN-TR3

AC Ground Fault Sensors, Mechanical Relay Output, Solid-Core, 120 VAC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Normally De-Energized, Top Terminals, SPDT 1 A @ 120 VAC, 2 A @ 30 VDC

NK Technologies

Quick Quote

AGL1-SDT1-24U-DEN-60

AGL1-SDT1-24U-DEN-60

Ground fault sensor with SPDT Relay output, Normally De-energized, Auto Reset, 24VAC/DC power supply, 60mA setpoin

NK Technologies

Quick Quote

ASXP2-SDT-120-FL

ASXP2-SDT-120-FL

NK Technologies - ASXP2-SDT-120-FL

NK Technologies

Quick Quote

ASXP8-SDT-24U-MS

ASXP8-SDT-24U-MS

NK Technologies - ASXP8-SDT-24U-MS

NK Technologies

Quick Quote

AG3-NCAC-24U-NF-TR3

AG3-NCAC-24U-NF-TR3

AC Ground Fault Sensors, Solid State Output, Solid-Core, 24 VAC/VDC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Normally De-Energized, Top Terminals, N.C. 1 A @ 240 VAC

NK Technologies

Quick Quote

AG3-NCDC-120-NF-TR3

AG3-NCDC-120-NF-TR3

AC Ground Fault Sensors, Solid State Output, Solid-Core, 120 VAC Powered, Jumper Select 5, 10 or 30 mA Setpoint, Normally De-Energized, Top Terminals, N.C. 0.15 A @ 30 VDC

NK Technologies

Quick Quote