ABB 2CSF202201R3630 is a Residual Current Circuit Breaker (RCCB) designed with screw-clamp connections and a rated current of 63A. It features a type A design and is suitable for DIN rail mounting. This RCCB has a rated insulation voltage (Ui) of 69 mm and a rated impulse voltage (Uimp) of 35 mm. The device is structured to accommodate 2-poles (2P) with a net width of 85 mm. It operates with a control voltage of 300mA and is designed for a supply voltage of 400 V. The RCCB is capable of 10,000 operations and supports 20,000 operations for its analog outputs. It also includes a number of Normally Closed (NC) circuits.
Quick Quote
Schneider Electric A9N18559 is an earth leakage add-on block designed for use with M.C.B., part of the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 3 Pole device with dimensions of 95 mm in height, 73 mm in depth, and 171 mm in width. The A9N18559 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 1000mA / 1A. It is designed to protect 3 poles.
Quick Quote
Schneider Electric A9R44440 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 4 Pole RCCB features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 300mA / 0.3A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The unit's dimensions are 91 mm in height, 73.5 mm in depth, and 72 mm in width. It is equipped with a rated insulation voltage (Ui) of 500 V and a rated operating voltage (Ue) of 415 V, with all four poles protected. The rated voltage (AC) phase-to-phase is 415 V.
Quick Quote
Schneider Electric A9N18599 is an earth leakage add-on block designed for use with miniature circuit breakers (M.C.B.) within the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 2-pole device, with dimensions of 95 mm in height, 73 mm in depth, and 198 mm in width. The A9N18599 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 500mA / 0.5A. It is designed to protect 2 poles.
Quick Quote
Schneider Electric A9N18560 is an earth leakage add-on block designed for use with M.C.B., part of the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 4 Pole device with dimensions of 95 mm in height, 73 mm in depth, and 198 mm in width. The A9N18560 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 300mA / 0.3A. All four poles are protected.
Quick Quote
Schneider Electric A9R21440 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 4-pole device features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 30mA / 0.03A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The RCCB has dimensions of 91 mm in height, 73.5 mm in depth, and 72 mm in width. It is rated for an insulation voltage (Ui) of 500 V, an operating voltage (Ue) of 415 V, and a phase-to-phase rated voltage (AC) of 415 V, with all 4 poles protected.
Quick Quote
Schneider Electric A9D73610 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the iSPN sub-range. It features a rated current of 10A and is designed for DIN rail mounting. This 2 Pole device has a net height of 93 mm, a depth of 70 mm, and a width of 18 mm. It operates at a rated voltage (AC) of 230V phase-to-neutral, with a residual current sensitivity of 30mA / 0.03A. The protected pole count is 1 Pole(s). It boasts a mechanical durability of 20,000 operations at no load and an electrical durability of 10,000 operations with load. The tripping curve is classified as C.
Quick Quote
Schneider Electric M9D14620 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the N40 Vigi sub-range. This 2-pole device has a rated current of 20A and is designed for DIN rail mounting. It features a residual current sensitivity of 300mA / 0.3A and operates at a rated voltage (AC) of 240V phase-to-neutral. The device protects 1 pole and is equipped with a C tripping curve.
Quick Quote
Schneider Electric A9V51225 is an earth leakage add-on block designed for use with miniature circuit breakers (M.C.B.) within the Vigi iC60 sub-range. This product features a rated current of 25A and is suitable for DIN rail mounting. It is a 2-pole device with dimensions of 91 mm in height, 73.5 mm in depth, and 63 mm in width. The A9V51225 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 30mA or 0.03A. It is designed to protect 2 poles.
Quick Quote
Item | Manufacturer | Price | Stock | Delivery | |
---|---|---|---|---|---|
2CSF202201R3630 ABB 2CSF202201R3630 is a Residual Current Circuit Breaker (RCCB) designed with screw-clamp connections and a rated current of 63A. It features a type A design and is suitable for DIN rail mounting. This RCCB has a rated insulation voltage (Ui) of 69 mm and a rated impulse voltage (Uimp) of 35 mm. The device is structured to accommodate 2-poles (2P) with a net width of 85 mm. It operates with a control voltage of 300mA and is designed for a supply voltage of 400 V. The RCCB is capable of 10,000 operations and supports 20,000 operations for its analog outputs. It also includes a number of Normally Closed (NC) circuits. | ABB Control | Quick Quote | |||
A9N18559 Schneider Electric A9N18559 is an earth leakage add-on block designed for use with M.C.B., part of the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 3 Pole device with dimensions of 95 mm in height, 73 mm in depth, and 171 mm in width. The A9N18559 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 1000mA / 1A. It is designed to protect 3 poles. | Schneider Electric | Quick Quote | |||
A9R44440 Schneider Electric A9R44440 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 4 Pole RCCB features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 300mA / 0.3A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The unit's dimensions are 91 mm in height, 73.5 mm in depth, and 72 mm in width. It is equipped with a rated insulation voltage (Ui) of 500 V and a rated operating voltage (Ue) of 415 V, with all four poles protected. The rated voltage (AC) phase-to-phase is 415 V. | Schneider Electric | Quick Quote | |||
A9N18599 Schneider Electric A9N18599 is an earth leakage add-on block designed for use with miniature circuit breakers (M.C.B.) within the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 2-pole device, with dimensions of 95 mm in height, 73 mm in depth, and 198 mm in width. The A9N18599 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 500mA / 0.5A. It is designed to protect 2 poles. | Schneider Electric | Quick Quote | |||
A9N18560 Schneider Electric A9N18560 is an earth leakage add-on block designed for use with M.C.B., part of the Vigi C120 sub-range. This product features a rated current of 125A and is suitable for DIN rail mounting. It is a 4 Pole device with dimensions of 95 mm in height, 73 mm in depth, and 198 mm in width. The A9N18560 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 300mA / 0.3A. All four poles are protected. | Schneider Electric | Quick Quote | |||
A9R21440 Schneider Electric A9R21440 is a Residual Current Circuit Breaker (RCCB) within the iID sub-range, designed for DIN rail mounting. This 4-pole device features a rated impulse voltage (Uimp) of 6 kV, a rated current of 40A, and a residual current sensitivity of 30mA / 0.03A. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 15,000 operations with load. The RCCB has dimensions of 91 mm in height, 73.5 mm in depth, and 72 mm in width. It is rated for an insulation voltage (Ui) of 500 V, an operating voltage (Ue) of 415 V, and a phase-to-phase rated voltage (AC) of 415 V, with all 4 poles protected. | Schneider Electric | Quick Quote | |||
A9D73610 Schneider Electric A9D73610 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the iSPN sub-range. It features a rated current of 10A and is designed for DIN rail mounting. This 2 Pole device has a net height of 93 mm, a depth of 70 mm, and a width of 18 mm. It operates at a rated voltage (AC) of 230V phase-to-neutral, with a residual current sensitivity of 30mA / 0.03A. The protected pole count is 1 Pole(s). It boasts a mechanical durability of 20,000 operations at no load and an electrical durability of 10,000 operations with load. The tripping curve is classified as C. | Schneider Electric | Quick Quote | |||
56192 Schneider Electric 56192 | Schneider Electric | Quick Quote | |||
M9D14620 Schneider Electric M9D14620 is a Residual Current Circuit Breaker with Overload protection (RCBO) / Earth Leakage Circuit Breaker (ELCB) from the N40 Vigi sub-range. This 2-pole device has a rated current of 20A and is designed for DIN rail mounting. It features a residual current sensitivity of 300mA / 0.3A and operates at a rated voltage (AC) of 240V phase-to-neutral. The device protects 1 pole and is equipped with a C tripping curve. | Schneider Electric | Quick Quote | |||
A9V51225 Schneider Electric A9V51225 is an earth leakage add-on block designed for use with miniature circuit breakers (M.C.B.) within the Vigi iC60 sub-range. This product features a rated current of 25A and is suitable for DIN rail mounting. It is a 2-pole device with dimensions of 91 mm in height, 73.5 mm in depth, and 63 mm in width. The A9V51225 operates at a rated voltage of 230 V AC phase-to-neutral and 415 V AC phase-to-phase, with a residual current sensitivity of 30mA or 0.03A. It is designed to protect 2 poles. | Schneider Electric | Quick Quote |